An overview of qualimetric strategies for optimisation and calibration in pharmaceutical analysis using flow injection techniques

被引:11
|
作者
Bosque-Sendra, JM [1 ]
Gámiz-Gracia, L [1 ]
García-Campaña, AM [1 ]
机构
[1] Univ Granada, Fac Sci, Dept Analyt Chem, E-18071 Granada, Spain
关键词
D O I
10.1007/s00216-003-2142-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Flow Injection analysis represents an attractive tool because of its great advantages, such as versatility, speed, high sampling rate and wide applicability in the field of pharmaceutical analysis. However, due to the inherent characteristics of the technique, the choice of the best set of operational and chemical conditions is complicated and the conventional univariate optimisation method present some limitations, mainly due to fact that the interdependence of variables is not considered. In relation to the calibration process, because of the transient character of the signals obtained using FIA manifolds coupled with different detection techniques, different strategies can be used in calibration to solve some problems related to the nature of the signal thereby improving the performance characteristics of the method. This paper offers an overview of different methodologies used in optimisation based on the use of statistically designed experiments and some strategies developed for calibration applied to the analysis of pharmaceuticals.
引用
收藏
页码:863 / 874
页数:12
相关论文
共 50 条
  • [1] An overview of qualimetric strategies for optimisation and calibration in pharmaceutical analysis using flow injection techniques
    J. M. Bosque-Sendra
    L. Gámiz-Gracia
    A. M. García-Campaña
    Analytical and Bioanalytical Chemistry, 2003, 377 : 863 - 874
  • [2] Univariate calibration techniques in flow injection analysis
    Koscielniak, P
    ANALYTICA CHIMICA ACTA, 2001, 438 (1-2) : 323 - 333
  • [3] FLOW-INJECTION CALIBRATION TECHNIQUES
    TYSON, J
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 329 (06): : 663 - 667
  • [4] The automation of pharmaceutical analysis using sequential-injection techniques
    Liu, XZ
    Fang, ZL
    LABORATORY ROBOTICS AND AUTOMATION, 2000, 12 (02) : 60 - 66
  • [5] Compaction analysis and optimisation of convex-faced pharmaceutical tablets using numerical techniques
    Baroutaji, Ahmad
    Lenihan, Sandra
    Bryan, Keith
    PARTICUOLOGY, 2019, 47 : 10 - 21
  • [6] DOUBLE-INJECTION FLOW-INJECTION ANALYSIS USING MULTIVARIATE CALIBRATION FOR MULTICOMPONENT ANALYSIS
    WHITMAN, DA
    SEASHOLTZ, MB
    CHRISTIAN, GD
    RUZICKA, J
    KOWALSKI, BR
    ANALYTICAL CHEMISTRY, 1991, 63 (08) : 775 - 781
  • [7] An Overview of the Generations and Recent Versions of Flow Injection Techniques
    Idris, Abubakr M.
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2010, 40 (03) : 150 - 158
  • [8] Flow analysis techniques for phosphorus:: an overview
    Estela, JM
    Cerdà, V
    TALANTA, 2005, 66 (02) : 307 - 331
  • [9] A COMPREHENSIVE OVERVIEW ON THE APPLICATION OF FLOW-INJECTION TECHNIQUES IN IMMUNOANALYSIS
    PUCHADES, R
    MAQUIEIRA, A
    ATIENZA, J
    MONTOYA, A
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1992, 23 (04) : 301 - 321
  • [10] Flow-injection analysis of ambroxol in pharmaceutical tablets
    Benli, P