Univariate calibration techniques in flow injection analysis

被引:31
|
作者
Koscielniak, P [1 ]
机构
[1] Jagiellonian Univ, Dept Analyt Chem, PL-30060 Krakow, Poland
关键词
FIA calibration; calibration techniques; calibration methods;
D O I
10.1016/S0003-2670(01)00860-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A critical view of univariate calibration techniques developed in the flow injection analysis (FIA) is presented. A classification system based on three main calibration categories - interpolative, extrapolative or indicative - is proposed and rationale behind it discussed. Then, the reasons for rather poor applicability of FIA techniques to routine analysis are considered from various points of view. Finally, a novel approach to the FIA calibration is suggested: the integrated calibration technique. It is believed to be more acceptable in analytical practice due to such features (discussed theoretically and shown experimentally) as reliability, simplicity, versatility and procedural similarity to the common batch calibration technique. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:323 / 333
页数:11
相关论文
共 50 条
  • [1] FLOW-INJECTION CALIBRATION TECHNIQUES
    TYSON, J
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 329 (06): : 663 - 667
  • [2] Review and classification of univariate interpolative calibration procedures in flow analysis
    Koscielniak, P
    Kozak, J
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2004, 34 (01) : 25 - 37
  • [3] Review of univariate standard addition calibration procedures in flow analysis
    Koscielniak, P
    Kozak, J
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2006, 36 (01) : 27 - 40
  • [4] An overview of qualimetric strategies for optimisation and calibration in pharmaceutical analysis using flow injection techniques
    Bosque-Sendra, JM
    Gámiz-Gracia, L
    García-Campaña, AM
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (05) : 863 - 874
  • [5] An overview of qualimetric strategies for optimisation and calibration in pharmaceutical analysis using flow injection techniques
    J. M. Bosque-Sendra
    L. Gámiz-Gracia
    A. M. García-Campaña
    Analytical and Bioanalytical Chemistry, 2003, 377 : 863 - 874
  • [6] PERMEATION TUBES FOR CALIBRATION IN FLOW-INJECTION ANALYSIS
    CHALK, SJ
    TYSON, JF
    OLSON, DC
    ANALYST, 1993, 118 (09) : 1227 - 1231
  • [7] A new approach to the integrated calibration in flow injection analysis
    Koscielniak, P
    Akcin, G
    Herman, M
    Kozak, J
    Wieczorek, M
    ANNALI DI CHIMICA, 2003, 93 (12) : 1045 - 1058
  • [8] FLOW-INJECTION TECHNIQUES FOR TRACE ANALYSIS
    WORSFOLD, PJ
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1990, 333 (1628): : 162 - 162
  • [9] Flow Injection, Overlooked Techniques in Forensic Analysis
    Idris, Abubakr M.
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2010, 40 (04) : 218 - 225
  • [10] DOUBLE-INJECTION FLOW-INJECTION ANALYSIS USING MULTIVARIATE CALIBRATION FOR MULTICOMPONENT ANALYSIS
    WHITMAN, DA
    SEASHOLTZ, MB
    CHRISTIAN, GD
    RUZICKA, J
    KOWALSKI, BR
    ANALYTICAL CHEMISTRY, 1991, 63 (08) : 775 - 781