Improving wedged field dose distributions

被引:10
|
作者
Keall, P
Zavgorodni, S
Schmidt, L
Haskard, D
机构
[1] QUEENSLAND UNIV TECHNOL,SCH PHYS,BRISBANE,QLD,AUSTRALIA
[2] ROYAL ADELAIDE HOSP,DEPT MED PHYS,ADELAIDE,SA 5000,AUSTRALIA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1997年 / 42卷 / 11期
关键词
D O I
10.1088/0031-9155/42/11/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dose profiles produced by wedge filters in the non-wedged direction can exhibit a 7% or greater dose reduction at the outer ends of the field compared with open field profiles. However, many planning systems use open field profiles to model wedged dose distributions. In the present work, wedges have been modified to reproduce open field profile shapes. This modification involved removing varying thicknesses of the wedge using a simple milling machine. The wedge thickness was calculated using the assumption that dose is proportional to primary collision kerma. The discrepancies in dose between wedged field and open field profile shapes of up to 7% were reduced to less than 3% with the modifications, even for varying depths and off-axis distances. The necessary measurements are simple to perform, and hence this technique could be applied to improve wedged field dose distributions in other radiotherapy departments.
引用
收藏
页码:2183 / 2192
页数:10
相关论文
共 50 条
  • [21] WEBSTER,EW - ATLAS OF RADIATION DOSE DISTRIBUTIONS . SINGLE FIELD ISODOSE CURVES
    JONES, JC
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1967, 18 (02): : 141 - &
  • [22] Dosimetric comparison of the field-in-field technique and tangential wedged beams for breast irradiation
    Onal, Cem
    Sonmez, Aydan
    Arslan, Gungor
    Oymak, Ezgi
    Kotek, Ayse
    Efe, Esma
    Sonmez, Serhat
    Dolek, Yemliha
    JAPANESE JOURNAL OF RADIOLOGY, 2012, 30 (03) : 218 - 226
  • [23] EXTENDING GENERAL FIELD EQUATION TO FIT DOSE DISTRIBUTIONS OF A VARIETY OF THERAPY UNITS
    WEINKAM, JJ
    KOLDE, RA
    STERLING, TD
    BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (551): : 983 - 990
  • [24] Improving the spectral resolution of wedged etalons and linear variable filters with incidence angle
    McLeod, RR
    Honda, T
    OPTICS LETTERS, 2005, 30 (19) : 2647 - 2649
  • [25] DOSE DISTRIBUTIONS IN RADIOSURGERY
    PIKE, GB
    PODGORSAK, EB
    PETERS, TM
    PLA, C
    OLIVIER, A
    SOUHAMI, L
    MEDICAL PHYSICS, 1990, 17 (02) : 296 - 304
  • [26] Mapping dose distributions
    Beckett, C
    Dickof, P
    MEDICAL PHYSICS, 1998, 25 (10) : 1944 - 1953
  • [27] Real-time dose reconstruction for wedged photon beams: a generalized procedure
    Piermattei, A.
    Greco, F.
    Fidanzio, A.
    Azario, L.
    Porcelli, A.
    Cilla, S.
    Sabatino, D.
    Russo, A.
    D'Onofrio, G.
    Russo, M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (04): : 124 - 138
  • [28] Dosimetric comparison of the field-in-field technique and tangential wedged beams for breast irradiation
    Cem Onal
    Aydan Sonmez
    Gungor Arslan
    Ezgi Oymak
    Ayse Kotek
    Esma Efe
    Serhat Sonmez
    Yemliha Dolek
    Japanese Journal of Radiology, 2012, 30 : 218 - 226
  • [29] Cumulating static dose distributions to simulate dynamic dose distributions: An experimental study
    Ayadi, M.
    Sarrut, D.
    Ginestet, C.
    MEDICAL PHYSICS, 2006, 33 (06) : 2084 - 2084
  • [30] An Analytical Modeling of Field Electron Emission for a Vertical Wedged Ordered Nanostructure
    Shen, Yan
    Xu, Ningsheng
    Ye, Peng
    Zhang, Yu
    Liu, Fei
    Chen, Jun
    She, Juncong
    Deng, Shaozhi
    ADVANCED ELECTRONIC MATERIALS, 2017, 3 (10):