Dosimetric comparison of the field-in-field technique and tangential wedged beams for breast irradiation

被引:0
|
作者
Cem Onal
Aydan Sonmez
Gungor Arslan
Ezgi Oymak
Ayse Kotek
Esma Efe
Serhat Sonmez
Yemliha Dolek
机构
[1] Baskent University Faculty of Medicine,Department of Radiation Oncology, Adana Research and Treatment Centre
来源
关键词
Breast cancer; Radiotherapy; Field-in-field technique; Tangential field technique; Intensity-modulated radiotherapy;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:218 / 226
页数:8
相关论文
共 50 条
  • [1] Dosimetric comparison of the field-in-field technique and tangential wedged beams for breast irradiation
    Onal, Cem
    Sonmez, Aydan
    Arslan, Gungor
    Oymak, Ezgi
    Kotek, Ayse
    Efe, Esma
    Sonmez, Serhat
    Dolek, Yemliha
    JAPANESE JOURNAL OF RADIOLOGY, 2012, 30 (03) : 218 - 226
  • [2] GEOMETRIC AND DOSIMETRIC APPROACH TO DETERMINE PROBABILITY OF LATE CARDIAC MORTALITY IN LEFT TANGENTIAL BREAST IRRADIATION: COMPARISON BETWEEN WEDGED BEAMS AND FIELD-IN-FIELD TECHNIQUE
    Pili, Giorgio
    Grimaldi, Luca
    Fidanza, Christian
    Florio, Elena T.
    Petruzzelli, Maria F.
    D'Errico, Maria P.
    De Tommaso, Cristina
    Tramacere, Francesco
    Musaio, Francesca
    Castagna, Roberta
    Francavilla, Maria C.
    Gianicolo, Emilio A. L.
    Portaluri, Maurizio
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (03): : 894 - 900
  • [3] USEFULNESS OF FIELD-IN-FIELD TECHNIQUE (FIF) IN WHOLE BREAST RADIOTYERAPY -COMPARISON WITH STANDARD WEDGED TANGENTIAL TECHNIQUE (WT) IN DOSIMETRIC AND TECHNICAL STABILITY-
    Kobayashi, K.
    Yamazaki, H.
    Tsubokura, T.
    Kodani, N.
    Aibe, N.
    Hashiba, M.
    Nishimura, T.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S306 - S306
  • [4] Performance evaluation of field-in-field technique for tangential breast irradiation
    Lee, Jeong-Woo
    Hong, Semie
    Choi, Kyoung-Sik
    Kim, Yon-Lae
    Park, Byung-Moon
    Chung, Jin-Beom
    Lee, Doo-Hyun
    Suh, Tae-Suk
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2008, 38 (02) : 158 - 163
  • [5] FIELD-IN-FIELD VERSUS CONVENTIONAL TANGENTIAL PLANNING TECHNIQUE FOR BREAST IRRADIATION
    Araujo, M.
    Rocha, F.
    Oliveira, A. C.
    Gaspar, J.
    Conceicao, L.
    Lopes, M. D. C.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S578 - S579
  • [6] Dosimetric Evaluation of the Field-in-Field Technique for Large Breast Cancer Irradiation
    Elywa, Mohammed
    Elnabawy, Shaimaa
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2018, 51 (04): : 168 - 174
  • [7] Comparison of Field in Field and Tangential Wedged Beams techniques in radiotherapy of breast cancer
    Yarahmadi, M.
    Haghparast, A.
    Faramarzi, B.
    Saalehi, Z.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1074 - S1074
  • [8] Dosimetric improvement of virtual wedged technique for tangential breast irradiation
    Kim, YS
    Oh, TY
    Rhu, MR
    Chung, SM
    Kim, H
    Yoon, SC
    RADIOLOGY, 2001, 221 : 176 - 176
  • [9] Field-in-field plan does not improve the dosimetric outcome compared with the wedged beams plan for breast cancer radiotherapy
    Sun, Li-Min
    Meng, Fan-Yun
    Yang, Tsung-Han
    Tsao, Min-Jen
    MEDICAL DOSIMETRY, 2014, 39 (01) : 79 - 82
  • [10] Dosimetric Comparison of Whole Breast Irradiation Using Helical Tomographic Technique and Static Multileaf Collimated Field-In-Field Technique
    Hsieh, H.
    Chang, S.
    Yuan, J.
    Pino-y-Torres, J.
    Chen, W.
    MEDICAL PHYSICS, 2008, 35 (06)