Improving wedged field dose distributions

被引:10
|
作者
Keall, P
Zavgorodni, S
Schmidt, L
Haskard, D
机构
[1] QUEENSLAND UNIV TECHNOL,SCH PHYS,BRISBANE,QLD,AUSTRALIA
[2] ROYAL ADELAIDE HOSP,DEPT MED PHYS,ADELAIDE,SA 5000,AUSTRALIA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1997年 / 42卷 / 11期
关键词
D O I
10.1088/0031-9155/42/11/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dose profiles produced by wedge filters in the non-wedged direction can exhibit a 7% or greater dose reduction at the outer ends of the field compared with open field profiles. However, many planning systems use open field profiles to model wedged dose distributions. In the present work, wedges have been modified to reproduce open field profile shapes. This modification involved removing varying thicknesses of the wedge using a simple milling machine. The wedge thickness was calculated using the assumption that dose is proportional to primary collision kerma. The discrepancies in dose between wedged field and open field profile shapes of up to 7% were reduced to less than 3% with the modifications, even for varying depths and off-axis distances. The necessary measurements are simple to perform, and hence this technique could be applied to improve wedged field dose distributions in other radiotherapy departments.
引用
收藏
页码:2183 / 2192
页数:10
相关论文
共 50 条
  • [41] IMPROVEMENT OF SMALL-FIELD PENUMBRA AND DOSE DISTRIBUTIONS ON A 4-MV ACCELERATOR
    NATH, R
    AGOSTINELLI, AG
    GIGNAC, CE
    SCHULZ, RJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (07): : 957 - 959
  • [42] The effects of small field dosimetry on the biological models used in evaluating IMRT dose distributions
    Cardarelli, G. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S596 - S597
  • [43] Simplified estimation method for dose distributions around field junctions in proton craniospinal irradiation
    Yamashita H.
    Kase Y.
    Murayama S.
    Radiological Physics and Technology, 2017, 10 (1) : 95 - 105
  • [44] Effect of transverse magnetic field on dose distributions of yttrium 90 skin patch source
    Epik, Hakan
    REVISTA MEXICANA DE FISICA, 2023, 69 (03)
  • [45] THE WEDGED-POLE CONCEPT FOR IMPROVING THE PERFORMANCE OF PERMANENT-MAGNET HYBRID UNDULATORS
    QUIMBY, DC
    PINDROH, AL
    ROBINSON, KE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 259 (1-2): : 304 - 311
  • [46] Improving ABC for quantile distributions
    R. McVinish
    Statistics and Computing, 2012, 22 : 1199 - 1207
  • [47] Improving ABC for quantile distributions
    McVinish, R.
    STATISTICS AND COMPUTING, 2012, 22 (06) : 1199 - 1207
  • [48] IMPROVING THE TAXATION OF ANNUITY DISTRIBUTIONS
    KREISER, L
    DOMONKOS, J
    TAXES, 1987, 65 (09): : 586 - 593
  • [49] Dose-position and dose-volume histogram analysis of standard wedged and intensity modulated treatments in breast radiotherapy
    Donovan, EM
    Bleackley, NJ
    Evans, PM
    Reise, SF
    Yarnold, JR
    BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (900): : 967 - 973
  • [50] NEUTRON DOSE DISTRIBUTIONS AND RBE
    MORRISON, R
    EUROPEAN JOURNAL OF CANCER, 1974, 10 (05) : 326 - 326