Extraction of pacemaker and implantable cardioverter defibrillator leads: Patient and lead characteristics in relation to the requirement of extraction tools

被引:73
|
作者
Bracke, F [1 ]
Meijer, A [1 ]
Van Gelder, B [1 ]
机构
[1] Catharina Hosp, Dept Cardiol, NL-5602 ZA Eindhoven, Netherlands
来源
关键词
lead extraction; technique; laser; pacemaker; implantable defibrillator;
D O I
10.1046/j.1460-9592.2002.01037.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Effective tools for extraction of pacemaker and ICD leads have been developed in the past decennium. This study investigated the necessity of using these tools in addition to direct traction in relation to patient and lead characteristics. The study encompasses first attempts at extraction of consecutive pacemaker and ICD leads from the subpectoral area. A stepwise extraction protocol was used with traction first (directly or with a locking stylet) followed by laser sheath extraction if not successful, The indication, patient age, time from implant, fixation mechanism, location, and insertion site of the leads were studied in relation to the outcome of traction. A total of 145 leads in 83 patients were extracted. Leads were implanted for 71 +/- 61 months. Indication for extraction was infection in 96 leads and malfunction in 49 leads. There were 90 ventricular leads including 16 ICD leads. Forty-nine (34%) leads were extracted with traction; in 96 (66%) leads a laser sheath was necessary. All leads implanted for < 6 months could be removed with traction alone. In a multivariate logistic regression model, time from implant was the main factor determining success of traction (P < 0.001), but in case of infection the success rate increased (P = 0.004). In conclusion, time from implant is the decisive factor to judge the potential efficacy of lead extraction with direct traction, If leads are implanted for 6 months, the availability of additional extraction tools is necessary when lead extraction is considered. In addition to time from implant, infected leads have a better chance to be removed with traction although it is a much weaker predictor.
引用
收藏
页码:1037 / 1040
页数:4
相关论文
共 50 条
  • [1] Extraction of pacemaker and implantable cardioverter defibrillator leads
    Kantharia, BK
    Kutalek, SP
    CURRENT OPINION IN CARDIOLOGY, 1999, 14 (01) : 44 - 51
  • [2] Comparison between percutaneous extraction of implantable cardioverter defibrillator leads and pacemaker leads
    Klug, D.
    Marquie, C.
    Brigadeau, F.
    Guedon, L.
    Kouakam, C.
    Lacroix, D.
    Kacet, S.
    EUROPEAN HEART JOURNAL, 2008, 29 : 397 - 397
  • [3] Nonthoracotomy implantable defibrillator lead extraction: Results and comparison with extraction of pacemaker leads
    Saad, EB
    Saliba, WI
    Schweikert, RA
    Al-Khadra, AS
    Abdul-Karim, A
    Niebauer, MJ
    Wilkoff, BL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (10): : 1944 - 1950
  • [4] Implantable cardioverter defibrillator and pacemaker lead extraction: is it safe to do it again?
    Cubberley, A.
    Sharedalal, P.
    Shah, N.
    Essilfie, G.
    Burkman, G.
    Saltzman, H. E.
    Kutalek, S. P.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1800 - 1800
  • [5] Extraction of pacemaker and implantable cardioverter defibrillator leads: a single-centre study of electrosurgical and laser extraction
    Scott, Paul A.
    Chow, Whitney
    Ellis, Elizabeth
    Morgan, John M.
    Roberts, Paul R.
    EUROPACE, 2009, 11 (11): : 1501 - 1504
  • [6] Comparison of different modalities of pacemaker and implantable cardioverter defibrillator lead extraction.
    Padder, T
    Abdullah, B
    Hafeez, A
    Kantharial, B
    Padder, F
    Panjrath, G
    Samuels, F
    Baessler, C
    Saaril, C
    Kutalek, S
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (6A): : 65H - 65H
  • [7] Extraction of endocardial implantable cardioverter-defibrillator leads
    Le Franc, P
    Klug, D
    Jarwe, M
    Lacroix, D
    Delfaut, P
    Kouakam, C
    Kacet, S
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (02): : 187 - 191
  • [8] Optimal environment for pacemaker and implantable cardioverter-defibrillator lead extraction with a laser sheath
    Bracke, FA
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (11): : 1594 - 1594
  • [9] Evolution in Transvenous Extraction of Pacemaker and Implantable Cardioverter Defibrillator Leads Using a Mechanical Dilator Sheath
    Oto, Ali
    Aytemir, Kudret
    Canpolat, Ugur
    Yorgun, Hikmet
    Sahiner, Levent
    Kaya, Ergun Baris
    Kabakci, Giray
    Tokgozoglu, Lale
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (07): : 834 - 840
  • [10] SINGLE CENTRE EXPERIENCE WITH SEVERAL METHODS FOR EXTRACTION OF PERMANENT PACEMAKER AND IMPLANTABLE CARDIOVERTER DEFIBRILLATOR LEADS
    Oto, A.
    Aytemir, K.
    Yorgun, H.
    Canpolat, U.
    Ates, A. H.
    Sunman, H.
    Ulgen, A.
    Gurses, K. M.
    Kaya, E. B.
    Tokgozoglu, L.
    Kabakci, G.
    Ozkutlu, H.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 147 : S81 - S81