Measuring Ventricular Width on Cranial Computed Tomography: Feasibility of Dose Reduction in a Custom-Made Adult Phantom
被引:6
|
作者:
Daubner, D.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Dresden, Carl Gustav Carus Med Sch, Dept Neuroradiol, Dresden, GermanyUniv Dresden, Carl Gustav Carus Med Sch, Dept Neuroradiol, Dresden, Germany
Daubner, D.
[1
]
Spieth, S.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Dresden, Carl Gustav Carus Med Sch, Dept Radiol, Dresden, GermanyUniv Dresden, Carl Gustav Carus Med Sch, Dept Neuroradiol, Dresden, Germany
Spieth, S.
[2
]
Cerhova, J.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Dresden, Carl Gustav Carus Med Sch, Dept Neuroradiol, Dresden, GermanyUniv Dresden, Carl Gustav Carus Med Sch, Dept Neuroradiol, Dresden, Germany
Cerhova, J.
[1
]
Linn, J.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Dresden, Carl Gustav Carus Med Sch, Dept Neuroradiol, Dresden, GermanyUniv Dresden, Carl Gustav Carus Med Sch, Dept Neuroradiol, Dresden, Germany
Linn, J.
[1
]
Kirchhof, K.
论文数: 0引用数: 0
h-index: 0
机构:
Hosp Chemnitz, Dept Diagnost & Intervent Radiol & Neuroradiol, Chemnitz, GermanyUniv Dresden, Carl Gustav Carus Med Sch, Dept Neuroradiol, Dresden, Germany
Kirchhof, K.
[3
]
机构:
[1] Univ Dresden, Carl Gustav Carus Med Sch, Dept Neuroradiol, Dresden, Germany
[2] Univ Dresden, Carl Gustav Carus Med Sch, Dept Radiol, Dresden, Germany
Purpose: To estimate feasible dose reduction to reliably measure ventricular width in adults with hydrocephalus in follow-up cranial computed tomography (CCT) using a custom-made phantom. Materials and Methods: A gelatine-filled adult calvarium with embedded central fibers of two carrots representing the lateral ventricles was used as a phantom. The phantom was scanned 11 times with two CT scanners (LightSpeed Ultra, GE and Somatom Sensation, Siemens), using tube currents of 380/400, 350, 300, 250, 200, 150 and 100 mA, and tube voltages of 140, 120, 100 and 80 kV. The width of the carrots was measured at four sites in consensus decision of two principle investigators blinded to the scan parameters. Values measured at 380/400 mA and 140 kV served as a reference for the width of the ventricles. Measurements received 1 point if they did not differ more than 0.5 mm from the reference values. A maximum score of 4 could be achieved. Results: The relationship between the correct width measurement of the carrots (lateral ventricles) and the radiation dose can be described by a quadratic regression function. Pixel noise increases and accuracy of measurements decreases with a lower radiation dose. Starting from a tube current of 380/400 mA and a tube voltage of 140 kV, the dose can be reduced by 76 % for LightSpeed Ultra and by 80 % for Somatom Sensation provided that a margin of error of 37.5 % (score = 2.5) for correct width measurement of the carrots is accepted. Conclusion: Lowering the radiation dose by up to 48 % for LightSpeed Ultra and by 52 % for Somatom Sensation, compared to the standard protocol (120 kV and 400 mA) still allowed reliable measurements of ventricular widths in this model.
机构:
Kyushu Univ, Dept Hlth Sci, Fac Med Sci, Higashi Ku, 3-1-1 Maidashi, Fukuoka 8128582, JapanKyushu Univ, Grad Sch Med Sci, Dept Hlth Sci, Higashi Ku, 3-1-1 Maidashi, Fukuoka 8128582, Japan
Arimura, Hidetaka
Shirieda, Katsutoshi
论文数: 0引用数: 0
h-index: 0
机构:
Miyazaki City Tano Hosp, Dept Radiol, 7696 Otsu, Tano, Miyazaki 8891702, JapanKyushu Univ, Grad Sch Med Sci, Dept Hlth Sci, Higashi Ku, 3-1-1 Maidashi, Fukuoka 8128582, Japan
Shirieda, Katsutoshi
Kameda, Noboru
论文数: 0引用数: 0
h-index: 0
机构:
Fujimoto Gen Hosp, Dept Radiol, 17-1 Hayasuzu Cho, Miyakonojo, Miyazaki 8850081, JapanKyushu Univ, Grad Sch Med Sci, Dept Hlth Sci, Higashi Ku, 3-1-1 Maidashi, Fukuoka 8128582, Japan
Kameda, Noboru
Ohki, Masafumi
论文数: 0引用数: 0
h-index: 0
机构:
Kyushu Univ, Dept Hlth Sci, Fac Med Sci, Higashi Ku, 3-1-1 Maidashi, Fukuoka 8128582, JapanKyushu Univ, Grad Sch Med Sci, Dept Hlth Sci, Higashi Ku, 3-1-1 Maidashi, Fukuoka 8128582, Japan
Ohki, Masafumi
PHYSICS IN MEDICINE AND BIOLOGY,
2016,
61
(09):
: 3609
-
3636
机构:
Loma Linda Univ Hlth, Dept Urol, 11234 Anderson St,Room A560, Loma Linda, CA 92354 USALoma Linda Univ Hlth, Dept Urol, 11234 Anderson St,Room A560, Loma Linda, CA 92354 USA