Measuring Ventricular Width on Cranial Computed Tomography: Feasibility of Dose Reduction in a Custom-Made Adult Phantom

被引:6
|
作者
Daubner, D. [1 ]
Spieth, S. [2 ]
Cerhova, J. [1 ]
Linn, J. [1 ]
Kirchhof, K. [3 ]
机构
[1] Univ Dresden, Carl Gustav Carus Med Sch, Dept Neuroradiol, Dresden, Germany
[2] Univ Dresden, Carl Gustav Carus Med Sch, Dept Radiol, Dresden, Germany
[3] Hosp Chemnitz, Dept Diagnost & Intervent Radiol & Neuroradiol, Chemnitz, Germany
关键词
brain; radiation dose; CT-spiral; ventricular width; hydrocephalus; adults; NONENHANCED HEAD CT; IMAGE QUALITY; RADIATION; CHILDREN; LENS;
D O I
10.1055/s-0041-106072
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To estimate feasible dose reduction to reliably measure ventricular width in adults with hydrocephalus in follow-up cranial computed tomography (CCT) using a custom-made phantom. Materials and Methods: A gelatine-filled adult calvarium with embedded central fibers of two carrots representing the lateral ventricles was used as a phantom. The phantom was scanned 11 times with two CT scanners (LightSpeed Ultra, GE and Somatom Sensation, Siemens), using tube currents of 380/400, 350, 300, 250, 200, 150 and 100 mA, and tube voltages of 140, 120, 100 and 80 kV. The width of the carrots was measured at four sites in consensus decision of two principle investigators blinded to the scan parameters. Values measured at 380/400 mA and 140 kV served as a reference for the width of the ventricles. Measurements received 1 point if they did not differ more than 0.5 mm from the reference values. A maximum score of 4 could be achieved. Results: The relationship between the correct width measurement of the carrots (lateral ventricles) and the radiation dose can be described by a quadratic regression function. Pixel noise increases and accuracy of measurements decreases with a lower radiation dose. Starting from a tube current of 380/400 mA and a tube voltage of 140 kV, the dose can be reduced by 76 % for LightSpeed Ultra and by 80 % for Somatom Sensation provided that a margin of error of 37.5 % (score = 2.5) for correct width measurement of the carrots is accepted. Conclusion: Lowering the radiation dose by up to 48 % for LightSpeed Ultra and by 52 % for Somatom Sensation, compared to the standard protocol (120 kV and 400 mA) still allowed reliable measurements of ventricular widths in this model.
引用
下载
收藏
页码:73 / 81
页数:9
相关论文
共 48 条
  • [31] Prevalence of Protective Shielding Utilization for Radiation Dose Reduction in Adult Patients Undergoing Body Scanning Using Computed Tomography
    Safiullah, Shoaib
    Patel, Roshan
    Uribe, Brittany
    Spradling, Kyle
    Lall, Chandana
    Zhang, Lishi
    Okhunov, Zhamshid
    Clayman, Ralph V.
    Landman, Jaime
    JOURNAL OF ENDOUROLOGY, 2017, 31 (10) : 985 - 990
  • [32] Modeling the adult female phantom in the supine and prone postures and initial dose assessment in breast cancer diagnosis with Neutron Stimulated Emission Computed Tomography
    Araghian, N.
    Miri-Hakimabad, H.
    Rafat-Motavalli, L.
    RADIOPROTECTION, 2015, 50 (02) : 101 - 109
  • [33] Feasibility study of recalculation of the dose for lung cancer radiotherapy using cone beam computed tomography images from a linear accelerator: a heterogeneous phantom study
    Zhao, Zhi-Peng
    Mu, Xin
    He, Ming-Yuan
    Zhao, Hong-Fu
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (08): : 9747 - 9754
  • [34] RADIATION DOSE REDUCTION USING LOW KVP COMPUTED TOMOGRAPHY WITH ADAPTIVE STATISTICAL ITERATIVE RECONSTRUCTION FOR CONTOURING IN RADIOTHERAPY TREATMENT PLANNING: A PHANTOM STUDY
    Lam, W. W.
    Yu, S. K.
    Geng, H.
    Wong, W. K. R.
    Ho, Y. W.
    Liu, S. F.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S389 - S389
  • [35] Comparison of selected photon shield and organ-based tube current modulation for radiation dose reduction in head computed tomography: A phantom study
    Yuan, Zilong
    Liu, Tao
    Zhang, Biao
    Wu, Jiaxing
    He, Yaoyao
    Chen, Tiao
    Zhang, Zhaoxi
    Li, Cuiling
    Liu, Yulin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2023, 31 (04) : 745 - 756
  • [36] Reduction of the computed tomography dose to the gonads of adolescent and young adult males through use of a tungsten-containing rubber sheet
    Kosaka, Hiroyuki
    Tamura, Mikoto
    Hattori, Shota
    Monzen, Hajime
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (04) : 366 - 372
  • [37] Influence of the adaptive iterative dose reduction 3D algorithm on the detectability of low-contrast lesions and radiation dose repeatability in abdominal computed tomography: a phantom study
    Jeong Hee Yoon
    Jeong Min Lee
    Bo Yun Hur
    Jeehyun Baek
    Hackjoon Shim
    Joon Koo Han
    Byung Ihn Choi
    Abdominal Imaging, 2015, 40 : 1843 - 1852
  • [38] Influence of the adaptive iterative dose reduction 3D algorithm on the detectability of low-contrast lesions and radiation dose repeatability in abdominal computed tomography: a phantom study
    Yoon, Jeong Hee
    Lee, Jeong Min
    Hur, Bo Yun
    Baek, Jeehyun
    Shim, Hackjoon
    Han, Joon Koo
    Choi, Byung Ihn
    ABDOMINAL IMAGING, 2015, 40 (06): : 1843 - 1852
  • [39] Radiation Dose Reduction for Coronary Artery Calcium Scoring Using a Virtual Noniodine Algorithm on Photon-Counting Detector Computed-Tomography Phantom Data
    Fink, Nicola
    Zsarnoczay, Emese
    Schoepf, U. Joseph
    O'Doherty, Jim
    Griffith III, Joseph P. P.
    Pinos, Daniel
    Tesche, Christian
    Ricke, Jens
    Willemink, Martin J.
    Varga-Szemes, Akos
    Emrich, Tilman
    DIAGNOSTICS, 2023, 13 (09)
  • [40] Recommendation for reducing the crystalline lens exposure dose by reducing imaging field width in cone-beam computed tomography for image-guided radiation therapy: an anthropomorphic phantom study
    Yoshida, Tatsuya
    Sasaki, Koji
    Hayakawa, Tomoki
    Kawadai, Toshiyuki
    Shibasaki, Takako
    Kawasaki, Yoshiyuki
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (03) : 629 - 636