Diagnostic Performance of a Stand-Alone Central Blood Pressure Monitor: Application of Central Blood Pressure in the Diagnosis of High Blood Pressure

被引:21
|
作者
Cheng, Hao-Min [1 ,2 ,3 ]
Sung, Shih-Hsien [2 ,3 ,4 ]
Chuang, Shao-Yuan [5 ]
Pearson, Alan [6 ]
Tufanaru, Catalin [6 ]
White, Sarahlouise [6 ]
Yu, Wen-Chung [2 ,3 ,7 ]
Chen, Chen-Huan [1 ,2 ,3 ,4 ,7 ]
机构
[1] Taipei Vet Gen Hosp, Dept Med Educ, Taipei, Taiwan
[2] Taipei Vet Gen Hosp, Dept Med, Taipei, Taiwan
[3] Natl Yang Ming Univ, Dept Med, Taipei 112, Taiwan
[4] Natl Yang Ming Univ, Inst Publ Hlth, Taipei 112, Taiwan
[5] Natl Hlth Res Inst, Res Inst Populat Hlth Sci, Div Prevent Med & Hlth Serv, Miaoli, Taiwan
[6] Univ Adelaide, Fac Hlth Sci, Joanna Briggs Inst, Adelaide, SA, Australia
[7] Natl Yang Ming Univ, Cardiovasc Res Ctr, Taipei 112, Taiwan
关键词
blood pressure; central blood pressure; diagnostic accuracy; hypertension; Microlife WatchBP Office Central; oscillometric signals; pulse volume plethysmography; sensitivity and specificity; sphygmomanometer; MEASUREMENT ACCURACY; ARTERIAL COMPLIANCE; NONINVASIVE METHOD; HYPERTENSION; VALIDATION; PULSE; NITROGLYCERIN; SPECIFICITY; SENSITIVITY; PREVALENCE;
D O I
10.1093/ajh/hpt282
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Oscillometric central blood pressure (CBP) monitors have emerged as a new technology for blood pressure (BP) measurements. With a newly proposed diagnostic threshold for CBP, we investigated the diagnostic performance of a novel CBP monitor. We recruited a consecutive series of 138 subjects (aged 3093 years) without previous use of antihypertensive agents for simultaneous invasive and noninvasive measurements of BP in a catheterization laboratory. With the cutoff (CBP 130/90mm Hg) for high blood pressure (HBP), the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the novel CBP monitor were calculated with reference to the measured CBP. In comparison, the diagnostic performance of the conventional cuff BP was also evaluated. The noninvasive CBP for detecting HBP in a sample with a prevalence of 52% showed a sensitivity of 93% (95% confidence interval (CI) 9195), specificity of 95% (95% CI 9497), PPV of 96% (95% CI 9497), and NPV of 93% (95% CI 9095). In contrast, with cuff BP and the traditional HBP criterion (cuff BP 140/90mm Hg), the sensitivity, specificity, PPV, and NPV were 49% (95% CI 4453), 94% (95% CI 9296), 90% (95% CI 8693), and 63% (95% CI 5966), respectively. A stand-alone oscillometric CBP monitor may provide CBP values with acceptable diagnostic accuracy. However, with reference to invasively measured CBP, cuff BP had low sensitivity and NPV, which could render possible management inaccessible to a considerable proportion of HBP patients, who may be identifiable through noninvasive CBP measurements from the CBP monitor.
引用
收藏
页码:382 / 391
页数:10
相关论文
共 50 条
  • [1] DIAGNOSTIC PERFORMANCE OF A STAND-ALONE CENTRAL BLOOD PRESSURE MONITOR: APPLICATION OF CENTRAL BLOOD PRESSURE IN THE DIAGNOSIS OF HIGH BLOOD PRESSURE
    Cheng, Hao-Min
    Sung, Shih-Hsien
    Chuang, Shao-Yuan
    Chen, Chen-Huan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1446 - A1446
  • [2] Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central
    Verberk, Willem J.
    Cheng, Hao-Min
    Huang, Li-Chih
    Lin, Chia-Ming
    Teng, Yao-Pin
    Chen, Chen-Huan
    PULSE, 2015, 3 (3-4) : 205 - 216
  • [3] Measurement Accuracy of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Validation Report for Microlife WatchBP Office Central
    Cheng, Hao-Min
    Sung, Shih-Hsien
    Shih, Yuan-Ta
    Chuang, Shao-Yuan
    Yu, Wen-Chung
    Chen, Chen-Huan
    AMERICAN JOURNAL OF HYPERTENSION, 2013, 26 (01) : 42 - 50
  • [4] Estimation of central systolic blood pressure using an oscillometric blood pressure monitor
    Cheng, Hao-Min
    Wang, Kang-Ling
    Chen, Ying-Hwa
    Lin, Shing-Jong
    Chen, Lung-Ching
    Sung, Shih-Hsien
    Ding, Philip Yu-An
    Yu, Wen-Chung
    Chen, Jaw-Wen
    Chen, Chen-Huan
    HYPERTENSION RESEARCH, 2010, 33 (06) : 592 - 599
  • [5] Estimation of central systolic blood pressure using an oscillometric blood pressure monitor
    Hao-Min Cheng
    Kang-Ling Wang
    Ying-Hwa Chen
    Shing-Jong Lin
    Lung-Ching Chen
    Shih-Hsien Sung
    Philip Yu-An Ding
    Wen-Chung Yu
    Jaw-Wen Chen
    Chen-Huan Chen
    Hypertension Research, 2010, 33 : 592 - 599
  • [6] Estimation of Central Aortic Blood Pressure using a Noninvasive Automatic Blood Pressure Monitor
    Shih, Yuan-Ta
    Sun, Yi-Jung
    Chen, Chen-Huan
    Cheng, Hao-min
    Wei-Chih, Hu
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 497 - +
  • [7] Accurate Estimation of Central Systolic Blood Pressure Using an Oscillometric Blood Pressure Monitor
    Cheng, Hao-Min
    Wang, Kang-Lin
    Chen, Ying-Hwa
    Lin, Shing-Jong
    Chen, Lung-Ching
    Sung, Shih-Hsien
    Lee, Wen-Shin
    Ding, Philip Yu-An
    Yu, Wen-Chung
    Chen, Jaw-Wen
    Chen, Chen-Huan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A462 - A463
  • [8] Statins, Central Blood Pressure, and Blood Pressure Amplification
    Safar, Michel E.
    Protogerou, Athanase D.
    Blacher, Jacques
    CIRCULATION, 2009, 119 (01) : 9 - 12
  • [9] Measurement of Central Systolic Blood Pressure by Pulse Volume Plethysmography With a Noninvasive Blood Pressure Monitor
    Sung, Shih-Hsien
    Cheng, Hao-Min
    Chuang, Shao-Yuan
    Shih, Yuan-Ta
    Wang, Kang-Ling
    Chen, Ying-Hwa
    Lin, Shing-Jong
    Yu, Wen-Chung
    Chen, Chen-Huan
    AMERICAN JOURNAL OF HYPERTENSION, 2012, 25 (05) : 542 - 548
  • [10] Central hemodynamics and the discrepancy between central blood pressure and peripheral blood pressure
    Park, J-S
    Shin, J-H
    Park, J-B
    Choi, D-J
    Youn, H-J
    Park, C-G
    Kwan, J.
    Ahn, Y-K
    Kim, D-W
    Rim, S-J
    EUROPEAN HEART JOURNAL, 2013, 34 : 1048 - 1049