Diagnostic Performance of a Stand-Alone Central Blood Pressure Monitor: Application of Central Blood Pressure in the Diagnosis of High Blood Pressure

被引:21
|
作者
Cheng, Hao-Min [1 ,2 ,3 ]
Sung, Shih-Hsien [2 ,3 ,4 ]
Chuang, Shao-Yuan [5 ]
Pearson, Alan [6 ]
Tufanaru, Catalin [6 ]
White, Sarahlouise [6 ]
Yu, Wen-Chung [2 ,3 ,7 ]
Chen, Chen-Huan [1 ,2 ,3 ,4 ,7 ]
机构
[1] Taipei Vet Gen Hosp, Dept Med Educ, Taipei, Taiwan
[2] Taipei Vet Gen Hosp, Dept Med, Taipei, Taiwan
[3] Natl Yang Ming Univ, Dept Med, Taipei 112, Taiwan
[4] Natl Yang Ming Univ, Inst Publ Hlth, Taipei 112, Taiwan
[5] Natl Hlth Res Inst, Res Inst Populat Hlth Sci, Div Prevent Med & Hlth Serv, Miaoli, Taiwan
[6] Univ Adelaide, Fac Hlth Sci, Joanna Briggs Inst, Adelaide, SA, Australia
[7] Natl Yang Ming Univ, Cardiovasc Res Ctr, Taipei 112, Taiwan
关键词
blood pressure; central blood pressure; diagnostic accuracy; hypertension; Microlife WatchBP Office Central; oscillometric signals; pulse volume plethysmography; sensitivity and specificity; sphygmomanometer; MEASUREMENT ACCURACY; ARTERIAL COMPLIANCE; NONINVASIVE METHOD; HYPERTENSION; VALIDATION; PULSE; NITROGLYCERIN; SPECIFICITY; SENSITIVITY; PREVALENCE;
D O I
10.1093/ajh/hpt282
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Oscillometric central blood pressure (CBP) monitors have emerged as a new technology for blood pressure (BP) measurements. With a newly proposed diagnostic threshold for CBP, we investigated the diagnostic performance of a novel CBP monitor. We recruited a consecutive series of 138 subjects (aged 3093 years) without previous use of antihypertensive agents for simultaneous invasive and noninvasive measurements of BP in a catheterization laboratory. With the cutoff (CBP 130/90mm Hg) for high blood pressure (HBP), the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the novel CBP monitor were calculated with reference to the measured CBP. In comparison, the diagnostic performance of the conventional cuff BP was also evaluated. The noninvasive CBP for detecting HBP in a sample with a prevalence of 52% showed a sensitivity of 93% (95% confidence interval (CI) 9195), specificity of 95% (95% CI 9497), PPV of 96% (95% CI 9497), and NPV of 93% (95% CI 9095). In contrast, with cuff BP and the traditional HBP criterion (cuff BP 140/90mm Hg), the sensitivity, specificity, PPV, and NPV were 49% (95% CI 4453), 94% (95% CI 9296), 90% (95% CI 8693), and 63% (95% CI 5966), respectively. A stand-alone oscillometric CBP monitor may provide CBP values with acceptable diagnostic accuracy. However, with reference to invasively measured CBP, cuff BP had low sensitivity and NPV, which could render possible management inaccessible to a considerable proportion of HBP patients, who may be identifiable through noninvasive CBP measurements from the CBP monitor.
引用
收藏
页码:382 / 391
页数:10
相关论文
共 50 条
  • [41] Blood pressure is blood pressure is blood pressure: Or is it?
    Agarwal, Rajiv
    JOURNAL OF CLINICAL HYPERTENSION, 2017, 19 (03): : 303 - 304
  • [42] Interarm Differences in Brachial Blood Pressure and their Effect on the Derivation on Central Aortic Blood Pressure
    Peebles, Karen C.
    Tan, Isabella
    Cook, Mitchell T. D.
    Theobald, Davis A.
    Avolio, Alberto P.
    Butlin, Mark
    ARTERY RESEARCH, 2020, 26 (02) : 89 - 96
  • [43] Interarm Differences in Brachial Blood Pressure and their Effect on the Derivation on Central Aortic Blood Pressure
    Karen C. Peebles
    Isabella Tan
    Mitchell T. D. Cook
    Davis A. Theobald
    Alberto P. Avolio
    Mark Butlin
    Artery Research, 2020, 26 : 89 - 96
  • [44] Estimating peripheral blood pressure from central blood pressure by a transfer function method
    Rose, William C.
    Schell, Kathleen A.
    DiSabatino, Angela
    Stillabower, Michael E.
    FASEB JOURNAL, 2012, 26
  • [45] Ambulatory blood pressure phenotypes and isolated elevation of office central or brachial blood pressure
    Feitosa, Audes D. M.
    Paiva, Annelise M. G.
    Mota-Gomes, Marco A.
    Brandao, Andrea A.
    Sposito, Andrei C.
    Nadruz Jr, Wilson
    JOURNAL OF CLINICAL HYPERTENSION, 2020, 22 (10): : 1936 - 1940
  • [47] Central aortic Blood Pressure: Important Parameter for Diagnosis and Therapy
    Middeke, Martin
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2017, 142 (19) : 1430 - 1436
  • [48] Diagnosis of high blood pressure in children by means of ambulatory blood pressure monitoring
    Empar Lurbe
    Josep Redon
    Current Hypertension Reports, 2001, 3 (2) : 89 - 90
  • [49] Noninvasive Flow-Indexed Blood Pressure Is Superior to Stand-Alone Blood Pressure in Predicting Heart Failure: Data From the Heart and Soul Study
    Morlend, Robert
    Farzaneh-Far, Ramin
    Na, Bee Ya
    Schiller, Nelson B.
    Whooley, Mary A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A213 - A213
  • [50] Effects of acetazolamide on central blood pressure, peripheral blood pressure, and arterial distensibility at acute high altitude exposure
    Parati, Gianfranco
    Revera, Miriam
    Giuliano, Andrea
    Faini, Andrea
    Bilo, Grzegorz
    Gregorini, Francesca
    Lisi, Elisabetta
    Salerno, Sabrina
    Lombardi, Carolina
    Becerra, Carlos G. Ramos
    Mancia, Giuseppe
    Salvi, Paolo
    EUROPEAN HEART JOURNAL, 2013, 34 (10) : 759 - 766