Diagnostic Performance of a Stand-Alone Central Blood Pressure Monitor: Application of Central Blood Pressure in the Diagnosis of High Blood Pressure

被引:21
|
作者
Cheng, Hao-Min [1 ,2 ,3 ]
Sung, Shih-Hsien [2 ,3 ,4 ]
Chuang, Shao-Yuan [5 ]
Pearson, Alan [6 ]
Tufanaru, Catalin [6 ]
White, Sarahlouise [6 ]
Yu, Wen-Chung [2 ,3 ,7 ]
Chen, Chen-Huan [1 ,2 ,3 ,4 ,7 ]
机构
[1] Taipei Vet Gen Hosp, Dept Med Educ, Taipei, Taiwan
[2] Taipei Vet Gen Hosp, Dept Med, Taipei, Taiwan
[3] Natl Yang Ming Univ, Dept Med, Taipei 112, Taiwan
[4] Natl Yang Ming Univ, Inst Publ Hlth, Taipei 112, Taiwan
[5] Natl Hlth Res Inst, Res Inst Populat Hlth Sci, Div Prevent Med & Hlth Serv, Miaoli, Taiwan
[6] Univ Adelaide, Fac Hlth Sci, Joanna Briggs Inst, Adelaide, SA, Australia
[7] Natl Yang Ming Univ, Cardiovasc Res Ctr, Taipei 112, Taiwan
关键词
blood pressure; central blood pressure; diagnostic accuracy; hypertension; Microlife WatchBP Office Central; oscillometric signals; pulse volume plethysmography; sensitivity and specificity; sphygmomanometer; MEASUREMENT ACCURACY; ARTERIAL COMPLIANCE; NONINVASIVE METHOD; HYPERTENSION; VALIDATION; PULSE; NITROGLYCERIN; SPECIFICITY; SENSITIVITY; PREVALENCE;
D O I
10.1093/ajh/hpt282
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Oscillometric central blood pressure (CBP) monitors have emerged as a new technology for blood pressure (BP) measurements. With a newly proposed diagnostic threshold for CBP, we investigated the diagnostic performance of a novel CBP monitor. We recruited a consecutive series of 138 subjects (aged 3093 years) without previous use of antihypertensive agents for simultaneous invasive and noninvasive measurements of BP in a catheterization laboratory. With the cutoff (CBP 130/90mm Hg) for high blood pressure (HBP), the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the novel CBP monitor were calculated with reference to the measured CBP. In comparison, the diagnostic performance of the conventional cuff BP was also evaluated. The noninvasive CBP for detecting HBP in a sample with a prevalence of 52% showed a sensitivity of 93% (95% confidence interval (CI) 9195), specificity of 95% (95% CI 9497), PPV of 96% (95% CI 9497), and NPV of 93% (95% CI 9095). In contrast, with cuff BP and the traditional HBP criterion (cuff BP 140/90mm Hg), the sensitivity, specificity, PPV, and NPV were 49% (95% CI 4453), 94% (95% CI 9296), 90% (95% CI 8693), and 63% (95% CI 5966), respectively. A stand-alone oscillometric CBP monitor may provide CBP values with acceptable diagnostic accuracy. However, with reference to invasively measured CBP, cuff BP had low sensitivity and NPV, which could render possible management inaccessible to a considerable proportion of HBP patients, who may be identifiable through noninvasive CBP measurements from the CBP monitor.
引用
收藏
页码:382 / 391
页数:10
相关论文
共 50 条
  • [11] Central hemodynamics and the discrepancy between central blood pressure and brachial blood pressure
    Park, Jin-Sun
    Shin, Joon-Han
    Park, Jeong-Bae
    Choi, Dong-Ju
    Youn, Ho-Joong
    Park, Chang-Gyu
    Kwan, Jun
    Ahn, Youngkeun
    Kim, Dong-Woon
    Rim, Se-Joong
    Park, Seung-Woo
    Sung, Jidong
    Bae, Jang-Ho
    MEDICINE, 2022, 101 (40) : E30484
  • [12] VALIDATION REPORT FOR THE MICROLIFE CENTRAL BLOOD PRESSURE MONITOR
    Cheng, HaoMin
    Chen Chen-Huan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1641 - E1641
  • [13] ASSESSMENT OF CENTRAL BLOOD PRESSURE FOR CLINICAL APPLICATION
    Morgan, Trefor
    JOURNAL OF HYPERTENSION, 2016, 34 : E541 - E541
  • [14] Central Blood Pressure Estimation
    Murakami, Tomoaki
    JOURNAL OF ATHEROSCLEROSIS AND THROMBOSIS, 2023, 30 (09) : 1108 - 1110
  • [15] CENTRAL REGULATION OF BLOOD PRESSURE
    GUTMAN, J
    LEIBOWITZ, U
    GINATH, Y
    BERGMANN, F
    CHAIMOVITZ, M
    ISRAEL JOURNAL OF EXPERIMENTAL MEDICINE, 1964, 11 (04): : 210 - &
  • [16] CENTRAL REGULATION OF BLOOD PRESSURE
    BERGMANN, F
    GUTMAN, Y
    ACTA PHYSIOLOGICA LATINOAMERICANA, 1966, S 16 : 49 - &
  • [17] Central blood pressure and hypertension
    Safar, Michel E.
    Smulyan, Harold
    HYPERTENSION, 2008, 51 (04) : 819 - 820
  • [18] Comparison of two generalized transfer functions for measuring central systolic blood pressure by an oscillometric blood pressure monitor
    Y-T Shih
    H-M Cheng
    S-H Sung
    W-C Hu
    C-H Chen
    Journal of Human Hypertension, 2013, 27 : 204 - 210
  • [19] Comparison of two generalized transfer functions for measuring central systolic blood pressure by an oscillometric blood pressure monitor
    Shih, Y-T
    Cheng, H-M
    Sung, S-H
    Hu, W-C
    Chen, C-H
    JOURNAL OF HUMAN HYPERTENSION, 2013, 27 (03) : 204 - 210
  • [20] Blood pressure phenotypes in youth: advances in the application of central aortic pressure
    Avolio, Alberto
    Butlin, Mark
    JOURNAL OF HYPERTENSION, 2016, 34 (07) : 1254 - 1256