Measurement Accuracy of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Validation Report for Microlife WatchBP Office Central

被引:30
|
作者
Cheng, Hao-Min [1 ,2 ,4 ,5 ]
Sung, Shih-Hsien [3 ,4 ,6 ,7 ]
Shih, Yuan-Ta [8 ]
Chuang, Shao-Yuan [9 ]
Yu, Wen-Chung [3 ,4 ,5 ]
Chen, Chen-Huan [2 ,4 ,5 ,6 ,7 ]
机构
[1] Univ Adelaide, Fac Hlth Sci, Joanna Briggs Inst, Adelaide, SA, Australia
[2] Taipei Vet Gen Hosp, Dept Med Res & Educ, Taipei, Taiwan
[3] Taipei Vet Gen Hosp, Dept Med, Taipei, Taiwan
[4] Natl Yang Ming Univ, Cardiovasc Res Ctr, Taipei 112, Taiwan
[5] Natl Yang Ming Univ, Dept Med, Taipei 112, Taiwan
[6] Natl Yang Ming Univ, Inst Publ Hlth, Taipei 112, Taiwan
[7] Natl Yang Ming Univ, Community Med Res Ctr, Taipei 112, Taiwan
[8] Chung Yuan Christian Univ, Dept Biomed Engn, Chungli, Taiwan
[9] Natl Hlth Res Inst, Res Inst Populat Hlth Sci, Div Prevent Med & Hlth Serv, Miaoli, Taiwan
关键词
blood pressure; central pulse pressure; hypertension; oscillometric signals; pressure wave reflection; pulse volume plethysmography; pulse wave analysis; PULSE PRESSURE; UPPER-LIMB; INTERNATIONAL PROTOCOL; SYSTOLIC HYPERTENSION; CARDIOVASCULAR EVENTS; MEASURING DEVICES; AORTIC PRESSURE; WAVE-FORM; ARTERY; AMPLIFICATION;
D O I
10.1093/ajh/hps021
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
BACKGROUND The superiority of prognostic value of blood pressure (BP) measured at central aorta (CBP) over conventional brachial BP measured by cuff-based BP monitors has reignited the development of new non-invasive techniques for estimating CBP. The present study validated the accuracy of CBP measured by a newly developed stand-alone CBP monitor. METHODS The CBP monitor provided readings of brachial systolic BP (SBP), brachial diastolic BP (DBP), central SBP, and central pulse pressure (PP). Brachial PP and central DBP were calculated from the relevant readings. The accuracy of the brachial and central SBP, PP, and DBP was validated against the simultaneously recorded invasively measured central aortic SBP, PP, and DBP, according to the invasive standard requirements for the noninvasive brachial BP monitors from the Association for the Advancement of Medical Instrumentation (AAMI) in 85 subjects (255 measurements; age range, 30-93 years). RESULTS The mean differences of cuff BP with reference to the invasively measured central SBP, PP, and DBP were -2.6 +/- 9.0, -8.6 +/- 11.2, and 6.1 +/- 7.0 mm Hg, respectively, with the former two being obviously underestimated at high CBP and overestimated at low CBP. In contrast, the corresponding differences for the central SBP, PP, and DBP measured by the CBP monitor were -0.6 +/- 5.5, -0.4 +/- 7.0, and -0.2 +/- 6.5 mm Hg, respectively, without obvious systematic bias. The distribution of measurement errors for central SBP, PP, and DBP surpassed the AAMI criteria. CONCLUSION Central SBP, PP, and DBP can be measured accurately by a stand-alone automatic BP monitor.
引用
收藏
页码:42 / 50
页数:9
相关论文
共 50 条
  • [1] Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central
    Verberk, Willem J.
    Cheng, Hao-Min
    Huang, Li-Chih
    Lin, Chia-Ming
    Teng, Yao-Pin
    Chen, Chen-Huan
    [J]. PULSE, 2015, 3 (3-4) : 205 - 216
  • [2] VALIDATION REPORT FOR THE MICROLIFE CENTRAL BLOOD PRESSURE MONITOR
    Cheng, HaoMin
    Chen Chen-Huan
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1641 - E1641
  • [3] Validation of the Microlife WatchBP Office professional device for office blood pressure measurement according to the International Protocol
    Stergiou, G.
    Tzamouranis, D.
    Protogerou, A.
    Nasothimiou, E.
    Kapralos, C.
    [J]. JOURNAL OF HYPERTENSION, 2008, 26 : S481 - S481
  • [4] DIAGNOSTIC PERFORMANCE OF A STAND-ALONE CENTRAL BLOOD PRESSURE MONITOR: APPLICATION OF CENTRAL BLOOD PRESSURE IN THE DIAGNOSIS OF HIGH BLOOD PRESSURE
    Cheng, Hao-Min
    Sung, Shih-Hsien
    Chuang, Shao-Yuan
    Chen, Chen-Huan
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1446 - A1446
  • [5] Diagnostic Performance of a Stand-Alone Central Blood Pressure Monitor: Application of Central Blood Pressure in the Diagnosis of High Blood Pressure
    Cheng, Hao-Min
    Sung, Shih-Hsien
    Chuang, Shao-Yuan
    Pearson, Alan
    Tufanaru, Catalin
    White, Sarahlouise
    Yu, Wen-Chung
    Chen, Chen-Huan
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2014, 27 (03) : 382 - 391
  • [6] Accuracy of fully automated oscillometric central aortic blood pressure measurement techniques
    Gotzmann, Michael
    Hogeweg, Maximilian
    Seibert, Felix S.
    Rohn, Benjamin Johannes
    Bergbauer, Martin
    Babel, Nina
    Bauer, Frederic
    Muegge, Andreas
    Westhoff, Timm H.
    [J]. JOURNAL OF HYPERTENSION, 2020, 38 (02) : 235 - 242
  • [7] The impact of calibration approaches on the accuracy of oscillometric central aortic blood pressure measurement
    Gotzmann, Michael
    Hogeweg, Maximilian
    Bauer, Frederic
    Seibert, Felix S.
    Rohn, Benjamin J.
    Muegge, Andreas
    Babel, Nina
    Westhoff, Timm H.
    [J]. JOURNAL OF HYPERTENSION, 2020, 38 (11) : 2154 - 2160
  • [8] Validation of the Microlife WatchBP Home device for self home blood pressure measurement according to the International Protocol
    Stergiou, George S.
    Giovas, Periklis P.
    Gkino, Charilaos P.
    Patouras, John D.
    [J]. BLOOD PRESSURE MONITORING, 2007, 12 (03) : 185 - 188
  • [9] Estimation of central systolic blood pressure using an oscillometric blood pressure monitor
    Cheng, Hao-Min
    Wang, Kang-Ling
    Chen, Ying-Hwa
    Lin, Shing-Jong
    Chen, Lung-Ching
    Sung, Shih-Hsien
    Ding, Philip Yu-An
    Yu, Wen-Chung
    Chen, Jaw-Wen
    Chen, Chen-Huan
    [J]. HYPERTENSION RESEARCH, 2010, 33 (06) : 592 - 599
  • [10] Estimation of central systolic blood pressure using an oscillometric blood pressure monitor
    Hao-Min Cheng
    Kang-Ling Wang
    Ying-Hwa Chen
    Shing-Jong Lin
    Lung-Ching Chen
    Shih-Hsien Sung
    Philip Yu-An Ding
    Wen-Chung Yu
    Jaw-Wen Chen
    Chen-Huan Chen
    [J]. Hypertension Research, 2010, 33 : 592 - 599