Accuracy of fully automated oscillometric central aortic blood pressure measurement techniques

被引:34
|
作者
Gotzmann, Michael [1 ]
Hogeweg, Maximilian [2 ]
Seibert, Felix S. [3 ]
Rohn, Benjamin Johannes [3 ]
Bergbauer, Martin [2 ]
Babel, Nina [3 ]
Bauer, Frederic [3 ]
Muegge, Andreas [1 ]
Westhoff, Timm H. [3 ]
机构
[1] Ruhr Univ Bochum, Cardiol, St Josef Hosp Bochum, Univ Hosp, Bochum, Germany
[2] Marien Hosp Witten, Dept Internal Med, Witten, Germany
[3] Ruhr Univ Bochum, Med Dept 1, Marien Hosp Herne, Univ Hosp, Holkeskampring 40, D-44625 Herne, Germany
关键词
central aortic blood pressure; hypertension; measurement; oscillometric; ALL-CAUSE MORTALITY; NONINVASIVE ESTIMATION; APPLANATION TONOMETRY; CARDIOVASCULAR EVENTS; VALIDATION; ASSOCIATION; SPHYGMOCOR; PREVENTION; OUTCOMES; DEVICES;
D O I
10.1097/HJH.0000000000002237
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Central aortic blood pressure (cBP) is a valuable predictor of cardiovascular risk. The lack of fully automated measurement devices impeded an implementation in daily clinical practice so far. The present study compares two novel automated oscillometric devices with invasively measured cBP. Methods: From March 2017 to March 2018, we enrolled consecutive patients undergoing elective coronary angiography to this cross-sectional study. Noninvasive assessment of cBP was performed by the SphygmoCor XCEL device and the Mobil-O-Graph NG device simultaneously to invasive measurement. Results: Our study included 502 patients (228 women, 274 men) with a mean age of 67.9 +/- 11.6 years. The noninvasive measurement of cBP was successful in 498 patients (99%) with SphygmoCor XCEL device and in 441 patients (88%) with Mobil-O-Graph NG device (P = 0.451). Measurements of both devices revealed a high correlation to invasively measured systolic (SphygmoCor R-2 0.864, P R-2 0.763, P < 0.001) and diastolic (SphygmoCor R-2 0.772, P R-2 0.618, P < 0.001) cBP. Both devices slightly underestimated systolic and overestimated diastolic central blood pressure: biases were -5.0 +/- 7.7/0.5 +/- 6.2 mmHg with SphygmoCor XCEL and -6.0 +/- 10.4/3.6 +/- 8.3 mmHg with Mobil-O-Graph NG device. Correlations (R-2) were higher and biases were lower with the SphygmoCor device (P < 0.001 each). Conclusion: The present study is the largest validation study of noninvasive cBP measurement techniques so far and shows that two current automated oscillometric monitors are able to assess cBP with acceptable accuracy. Automated oscillometric devices may facilitate the implementation of cBP in daily clinical practice.
引用
收藏
页码:235 / 242
页数:8
相关论文
共 50 条
  • [1] The impact of calibration approaches on the accuracy of oscillometric central aortic blood pressure measurement
    Gotzmann, Michael
    Hogeweg, Maximilian
    Bauer, Frederic
    Seibert, Felix S.
    Rohn, Benjamin J.
    Muegge, Andreas
    Babel, Nina
    Westhoff, Timm H.
    [J]. JOURNAL OF HYPERTENSION, 2020, 38 (11) : 2154 - 2160
  • [2] Increasing the Accuracy of Oscillometric Blood Pressure Measurement
    Sutyagina, Anastasiya D.
    Shlyakhotka, Anna V.
    Lyakhova, Ekaterina K.
    [J]. PROCEEDINGS OF THE 2018 IEEE CONFERENCE OF RUSSIAN YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING (EICONRUS), 2018, : 1231 - 1234
  • [3] Automated Oscillometric Blood Pressure Measurement in Children
    Chiolero, Arnaud
    Bovet, Pascal
    Stergiou, George S.
    [J]. JOURNAL OF CLINICAL HYPERTENSION, 2014, 16 (06): : 468 - 468
  • [4] Accuracy of oscillometric blood pressure measurement in atrial fibrillation
    Feenstra, Rudolf K.
    Allaart, Cor P.
    Berkelmans, Gijs F. N.
    Westerhof, Berend E.
    Smulders, Yvo M.
    [J]. BLOOD PRESSURE MONITORING, 2018, 23 (02) : 59 - 63
  • [5] Accuracy of the automated oscillometric device Lohmeier B-606, for blood pressure measurement in hospitals
    Estrada, D
    Pujol, E
    Jiménez, L
    Santos, MJ
    Coca, A
    de la Sierra, A
    [J]. MEDICINA CLINICA, 2002, 119 (13): : 492 - 494
  • [6] Comparison of Automated Oscillometric Versus Auscultatory Blood Pressure Measurement
    Landgraf, Johanna
    Wishner, Stanley H.
    Kloner, Robert A.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (03): : 386 - 388
  • [7] ACCURACY OF BRACHIAL BLOOD PRESSURE RECORDINGS BY AUTOMATED CUFF COMPARED TO CENTRAL AORTIC PRESSURE
    Schwartz, L.
    Mighton, L. D.
    Dunlop, J.
    Shufelt, K.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2010, 26 : 125D - 125D
  • [8] Accuracy of automated oscillometric blood pressure monitors in the detection of cardiac arrhythmias
    Huang, Qi-Fang
    Sheng, Chang-Sheng
    Zhang, Yi
    Wang, Jie
    Li, Yan
    Wang, Ji-Guang
    [J]. BLOOD PRESSURE MONITORING, 2009, 14 (02) : 91 - 92
  • [9] THE ACCURACY OF CENTRAL BLOOD PRESSURE OBTAINED BY OSCILLOMETRIC NONINVASIVE METHOD IN CHILDREN
    Shiraishi, M.
    Murakami, T.
    [J]. JOURNAL OF HYPERTENSION, 2018, 36 : E72 - E73
  • [10] An Initial Step Towards Improving the Accuracy of the Oscillometric Blood Pressure Measurement
    Liu, Jiankun
    Hahn, Jin-Oh
    Mukkamala, Ramakrishna
    [J]. 2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 4082 - 4085