Three-dimensional accuracy assessment of eye surgeons

被引:0
|
作者
Hotraphinyo, LF [1 ]
Riviere, CN [1 ]
机构
[1] Carnegie Mellon Univ, Dept Elect & Comp Engn, Pittsburgh, PA 15213 USA
关键词
microsurgery; accuracy; optical sensing;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Overall manual accuracy in simulated microsurgery has been studied. Three eye surgeons have been tested thus far. Subjects attempted to hold a microsurgical instrument still for 30 s and its 3-D tip position was recorded. RMS error, overall motion range were calculated and spectral analysis was performed for each axis. The RMS error was between 54 mum and 118 mum and the overall range of motion was between 239 mum and 588 mum, depending on the axis. Substantial low frequency motion was present. Between 73.5% and 83.7% of the total power was found to be below 3 Hz, depending on the axis.
引用
收藏
页码:3458 / 3461
页数:4
相关论文
共 50 条
  • [1] Three-Dimensional Facial Scanning at the Fingertips of Patients and Surgeons: Accuracy and Precision Testing of iPhone X Three-Dimensional Scanner
    Rudy, Hayeem L.
    Wake, Nicole
    Yee, Judy
    Garfein, Evan S.
    Tepper, Oren M.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2020, 146 (06) : 1407 - 1417
  • [2] Three-dimensional assessment of lower limb alignment: Accuracy and reliability
    Fuermetz, J.
    Sass, J.
    Ferreira, T.
    Jalali, J.
    Kovacs, L.
    Mueck, F.
    Degen, N.
    Thaller, P. H.
    KNEE, 2019, 26 (01): : 185 - 193
  • [3] Accuracy of renal volume assessment in children by three-dimensional sonography
    Fritz, GA
    Riccabona, M
    Bohdal, G
    Quehenberger, F
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (04): : 540 - 546
  • [4] Dimensional accuracy achievable by three-dimensional printing
    Islam, M. N.
    Boswell, B.
    Pramanik, A.
    IAENG TRANSACTIONS ON ENGINEERING SCIENCES, 2014, : 263 - 268
  • [5] Assessment of Registration Accuracy in Three-Dimensional Transrectal Ultrasound Images of Prostates
    Karnik, V.
    Fenster, A.
    Bax, J.
    Cool, D.
    Gardi, L.
    Gyacskov, Igor
    Romagnoli, C.
    Ward, A. D.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [6] Accuracy assessment of a clinical biplane fluoroscope for three-dimensional measurements and targeting
    Schreiner, S
    Funda, J
    Barnes, AC
    Anderson, JH
    IMAGE DISPLAY - MEDICAL IMAGING 1997, 1997, 3031 : 160 - 166
  • [7] Assessment of accuracy and recognition of three-dimensional computerized forensic craniofacial reconstruction
    Miranda, Geraldo Elias
    Wilkinson, Caroline
    Roughley, Mark
    Beaini, Thiago Leite
    Haltenhoff Melani, Rodolfo Francisco
    PLOS ONE, 2018, 13 (05):
  • [8] Three-dimensional ultrasound imaging of the eye
    Downey, DB
    Nicolle, DA
    Levin, MF
    Fenster, A
    EYE, 1996, 10 : 75 - 81
  • [9] Diagnostic Accuracy of Maxillofacial Trauma Two-Dimensional and Three-Dimensional Computed Tomographic Scans: Comparison of Oral Surgeons, Head and Neck Surgeons, Plastic Surgeons, and Neuroradiologists
    Jarrahy, Reza
    Vo, Victoria
    Goenjian, Haig A.
    Tabit, Christina J.
    Katchikian, Hurig V.
    Kumar, Anand
    Meals, Clifton
    Bradley, James P.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2011, 127 (06) : 2432 - 2440
  • [10] Affine registration of three-dimensional point sets for improving the accuracy of eye position trackers
    Kang, Donghoon
    Kim, Jinwook
    Kim, Sung-Kyu
    OPTICAL ENGINEERING, 2017, 56 (04)