Accuracy of renal volume assessment in children by three-dimensional sonography

被引:19
|
作者
Fritz, GA
Riccabona, M
Bohdal, G
Quehenberger, F
机构
[1] Univ Klinikum Graz, Radiol Klin, Graz, Austria
[2] Univ Klinikum Graz, Inst Med Informat Stat & Dokumentat, Graz, Austria
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2003年 / 175卷 / 04期
关键词
tree-dimensional ultrasound; pediatric; volume; kidney; children;
D O I
10.1055/s-2003-38442
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Prospective evaluation of the accuracy of three-dimensional ultrasound (3DUS) to assess the renal parenchymal volume. Materials and Methods: CT, MRI, 2DUS and 3DUS were used to measure the renal volume in 40 patients (range: neonate to 17 years; mean age: 8.95 years). The 3DUS was determined with a Voluson 730 (Kretztechnik, GE) or an external 3D-system (EchoTech, GE) using electromagnetic positioning sensors attached to conventional 2DUS-equipment. The 2DUS volume was calculated with the ellipsoid equation and the 3DUS volume computed with the system integrated software. For CT and MRI, planimetric analysis was used to determine the renal parenchymal volume, whereby the dilated collecting system of a hydronephrosis was subtracted to obtain the real renal parenchymal volume. The results of 2DUS and 3DUS were compared to the results of CT and MRI, and inter- and intraobserver variabilities were calculated. Results: In 74 of 77 kidneys, the 3DUS study was of diagnostic quality. The accuracy of the 3DUS volumes compared well to the CT and MRI volumes with a mean difference of -1.8 +/- 4.6% versus a mean difference of -2.4 +/- 15.4% for 2DUS. In normal kidneys, the accuracy was -2.6 +/- 4.4% for 3DUS and -3.8 +/- 14.7 % for 2DUS. In hydronephrosis, the accuracy was +4.0 +/- 5.9% and +9.6 +/- 21.3 %, respectively, indicating that 3DUS is more accurate than 2DUS, particularly in kidneys with a dilated collecting system. Inter- and intraobserver variabilities were +/-7.3% and +/- 5.3%. Conclusion: For assessing the renal parenchymal volume in children, 3DUS is feasible and comparable to CT and MRI.
引用
收藏
页码:540 / 546
页数:7
相关论文
共 50 条
  • [1] Accuracy of fetal lung volume assessed by three-dimensional sonography
    Ruano, R
    Martinovic, J
    Dommergues, M
    Aubry, MC
    Dumez, Y
    Benachi, A
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 26 (07) : 725 - 730
  • [2] Accuracy of prostate volume measurements using transrectal multiplanar three-dimensional sonography
    Giubilei, G
    Ponchietti, R
    Biscioni, S
    Fanfani, A
    Ciatto, S
    Di Loro, F
    Gavazzi, A
    Mondaini, N
    INTERNATIONAL JOURNAL OF UROLOGY, 2005, 12 (10) : 936 - 938
  • [3] Fetal renal volume assessment by three-dimensional ultrasonography
    Hsieh, YY
    Chang, CC
    Lee, CC
    Tsai, HD
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2000, 182 (02) : 377 - 379
  • [4] Accuracy of three-dimensional ultrasound for thyroid volume measurement in children and adolescents
    Lyshchik, A
    Drozd, V
    Reiners, C
    THYROID, 2004, 14 (02) : 113 - 120
  • [5] Diagnostic accuracy of three-dimensional hysterosalpingo-contrast-sonography
    Coppus, SFPJ
    Mol, BWJ
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2006, 85 (04) : 508 - 509
  • [6] Accuracy and precision of in vitro volumetric measurements by three-dimensional sonography
    Wong, J
    Gerscovich, EO
    Cronan, MS
    Seibert, JA
    INVESTIGATIVE RADIOLOGY, 1996, 31 (01) : 26 - 29
  • [7] Three-dimensional breast volume assessment
    Gouveia, P.
    Monteiro, J. P.
    Oliveira, H. P.
    Cardoso, M. J.
    Cardoso, J. S.
    EUROPEAN JOURNAL OF CANCER, 2016, 57 : S75 - S75
  • [8] Choledochal cysts in children:: Evaluation with three-dimensional sonography
    Haliloglu, M
    Akata, D
    Gurel, S
    Özmen, MN
    Akhan, O
    JOURNAL OF CLINICAL ULTRASOUND, 2003, 31 (09) : 478 - 480
  • [9] The assessment of the pituitary volume in normal prepubertal children with three-dimensional MRI
    Aksan, Ilknur Okur
    Sari, Ahmet
    CUKUROVA MEDICAL JOURNAL, 2021, 46 (03): : 912 - 919
  • [10] Diagnostic accuracy of three-dimensional hysterosalpingo-contrast-sonography - Reply
    Chan, CCW
    Ng, EHY
    Tang, OS
    Chan, KKL
    Ho, PC
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2006, 85 (04) : 509 - 510