Three-dimensional accuracy assessment of eye surgeons

被引:0
|
作者
Hotraphinyo, LF [1 ]
Riviere, CN [1 ]
机构
[1] Carnegie Mellon Univ, Dept Elect & Comp Engn, Pittsburgh, PA 15213 USA
关键词
microsurgery; accuracy; optical sensing;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Overall manual accuracy in simulated microsurgery has been studied. Three eye surgeons have been tested thus far. Subjects attempted to hold a microsurgical instrument still for 30 s and its 3-D tip position was recorded. RMS error, overall motion range were calculated and spectral analysis was performed for each axis. The RMS error was between 54 mum and 118 mum and the overall range of motion was between 239 mum and 588 mum, depending on the axis. Substantial low frequency motion was present. Between 73.5% and 83.7% of the total power was found to be below 3 Hz, depending on the axis.
引用
收藏
页码:3458 / 3461
页数:4
相关论文
共 50 条
  • [31] Assessment of image registration accuracy in three-dimensional transrectal ultrasound guided prostate biopsy
    Karnik, V. V.
    Fenster, A.
    Bax, J.
    Cool, D. W.
    Gardi, L.
    Gyacskov, I.
    Romagnoli, C.
    Ward, A. D.
    MEDICAL PHYSICS, 2010, 37 (02) : 802 - 813
  • [32] Assessment of the accuracy of three-dimensional manual craniofacial reconstruction: a series of 25 controlled cases
    Gérald Quatrehomme
    Thierry Balaguer
    Pascal Staccini
    Véronique Alunni-Perret
    International Journal of Legal Medicine, 2007, 121 : 469 - 475
  • [33] Precision and accuracy assessment of single and multicamera three-dimensional photogrammetry compared with direct anthropometry
    Staller, Sable
    Anigbo, Justina
    Stewart, Kelton
    Dutra, Vinicius
    Turkkahraman, Hakan
    ANGLE ORTHODONTIST, 2022, 92 (05) : 635 - 641
  • [34] Assessment of the accuracy of three-dimensional manual craniofacial reconstruction: a series of 25 controlled cases
    Quatrehomme, Gerald
    Balaguer, Thierry
    Staccini, Pascal
    Alunni-Perret, Veronique
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2007, 121 (06) : 469 - 475
  • [35] Novel three-dimensional tactile markers on eye drop bottles improve accuracy of eye drop recognition for patients with low vision
    Mehta, Rajvi
    Aref, Ahmad A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [36] Accuracy and Feasibility of Three-Dimensional Ultrasound Testing in Eye Clinic and Emergency Department Patients with Vision Complaints
    Theophanous, Rebecca G.
    Gordee, Alexander
    Peethumnongsin, Erica
    Huang, Wennie
    Gurysh, Kevin
    Coco, Matthew
    Campos, Santiago Cantillo
    Ruderman, Brandon
    Kuchibhatla, Maragatha
    Broder, Joshua
    JOURNAL OF EMERGENCY MEDICINE, 2024, 66 (02): : 197 - 210
  • [37] Three-dimensional assessment of pectus excavatum
    Jorgensen, Jason R.
    Plasencia, Jonathan D.
    Notrica, David M.
    Sabati, Arash A.
    JTCVS TECHNIQUES, 2023, 22 : 334 - 336
  • [38] Three-dimensional breast volume assessment
    Gouveia, P.
    Monteiro, J. P.
    Oliveira, H. P.
    Cardoso, M. J.
    Cardoso, J. S.
    EUROPEAN JOURNAL OF CANCER, 2016, 57 : S75 - S75
  • [39] The Three-Dimensional Approach to Neuropsychiatric Assessment
    Marin, Robert S.
    JOURNAL OF NEUROPSYCHIATRY AND CLINICAL NEUROSCIENCES, 2012, 24 (04) : 384 - 393
  • [40] Three-dimensional assessment of hand outcome
    Pearl, R. A.
    Belcher, H. J. C. R.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2013, 95 (06) : 421 - 426