Three-dimensional assessment of lower limb alignment: Accuracy and reliability

被引:33
|
作者
Fuermetz, J. [1 ]
Sass, J. [1 ]
Ferreira, T. [2 ,3 ]
Jalali, J. [2 ]
Kovacs, L. [2 ]
Mueck, F. [4 ]
Degen, N. [1 ]
Thaller, P. H. [1 ]
机构
[1] Univ Hosp Munich LMU, Dept Gen Trauma & Reconstruct Surg, 3D Surg, Munich, Germany
[2] Tech Univ Munich, Univ Hosp Klinikum Rechts Isar, Dept Plast Surg & Hand Surg, Res Grp CAPS Comp Aided Plast Surg, Munich, Germany
[3] Univ Lisbon, Fac Sci, Lisbon, Portugal
[4] Univ Hosp Munich LMU, Dept Radiol, Munich, Germany
来源
KNEE | 2019年 / 26卷 / 01期
关键词
3D anatomy; 3D bone modeling; Alignment; Computed tomography; Patient-specific implant; Pre-operative planning; TOTAL KNEE ARTHROPLASTY; GUIDES; OSTEOTOMIES; DEFORMITIES;
D O I
10.1016/j.knee.2018.10.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Three-dimensional (3D) surgical planning and patient-specific implants are becoming increasingly popular in orthopedics and trauma surgery. In contrast to the established and standardized alignment assessment on two-dimensional (2D) long standing radiographs (LSRs) there is neither a standardized nor a validated protocol for the analysis of 3D bone models of the lower limb. This study aimed to create a prerequisite for pre-operative planning. Methods: According to 2D analysis and after meticulous research, 24 landmarks were defined on 3D bone models obtained from computed axial tomography (CT) scans for a 3D alignment assessment. Three observers with different experience levels performed the test three different times on three specimens. Intraobserver and interobserver variability of the landmarks and the intraclass correlation coefficient (ICC) of the resulting axes and joint angles were evaluated. Results: Overall, the intraobserver and interobserver variability was low, with a mean deviation <5 mm for all landmarks. The ICC of all joint angles and axis deviations was >0.8, except for tibial torsion (ICC = 0.69). All knee joint angles showed excellent ICC (>0.95). Conclusions: Using the defined landmarks, a standardized 3D alignment assessment with low intraobserver and interobserver variability and high ICC values for the knee joint angles can be performed regardless of examiner's experience. The described method serves as a reliable standardized protocol for a 3D malalignment test of the lower limb. Three-dimensional pre-operative analysis might enhance understanding of deformities and lead to a new focus in surgical planning. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:185 / 193
页数:9
相关论文
共 50 条
  • [1] Three-dimensional assessment of lower limb alignment: Reference values and sex-related differences
    Degen, N.
    Sass, J.
    Jalali, J.
    Kovacs, L.
    Euler, E.
    Prall, W. C.
    Boecker, W.
    Thaller, P. H.
    Fuermetz, J.
    KNEE, 2020, 27 (02): : 428 - 435
  • [2] Reliability of upper and lower limb three-dimensional kinematics in children with hemiplegia
    Mackey, AH
    Walt, SE
    Lobb, GA
    Stott, NS
    GAIT & POSTURE, 2005, 22 (01) : 1 - 9
  • [3] Three-Dimensional Imaging of Lower Limb Neuropathies
    Ahlawat, Shivani
    Carrino, John A.
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2015, 19 (02) : 168 - 178
  • [4] Reliability and Accuracy in Three-Dimensional Gait Analysis: A Comparison of Two Lower Body Protocols
    Stief, Felix
    Boehm, Harald
    Michel, Katja
    Schwirtz, Ansgar
    Doederlein, Leonhard
    JOURNAL OF APPLIED BIOMECHANICS, 2013, 29 (01) : 105 - 111
  • [5] Accuracy and reliability of automatic three-dimensional cephalometric landmarking
    Dot, G.
    Rafflenbeul, F.
    Arbotto, M.
    Gajny, L.
    Rouch, P.
    Schouman, T.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 49 (10) : 1367 - 1378
  • [6] Three-dimensional accuracy assessment of eye surgeons
    Hotraphinyo, LF
    Riviere, CN
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 3458 - 3461
  • [7] Radiological assessment of lower limb alignment
    Luis, Nuno Marques
    Varatojo, Ricardo
    EFORT OPEN REVIEWS, 2021, 6 (06) : 487 - 494
  • [8] Repeatability of lower limb three-dimensional kinematics in patients with stroke
    Yavuzer, Gunes
    Oeken, Oeznur
    Elhan, Atilla
    Stam, Henk J.
    GAIT & POSTURE, 2008, 27 (01) : 31 - 35
  • [9] Three-dimensional variations in the lower limb caused by the windlass mechanism
    Jose Manfredi-Marquez, Maria
    Tovaruela-Carrion, Natalia
    Tavara-Vidalon, Priscila
    Dominguez-Maldonado, Gabriel
    Maria Fernandez-Seguin, Lourdes
    Ramos-Ortega, Javier
    PEERJ, 2017, 5
  • [10] Three dimensional radiological imaging of normal lower-limb alignment in children
    Ádám Tibor Schlégl
    Kinga Szuper
    Szabolcs Somoskeöy
    Péter Than
    International Orthopaedics, 2015, 39 : 2073 - 2080