Swept-Source Optical Coherence Tomography Biometer as Screening Strategy for Macular Disease in Patients Scheduled for Cataract Surgery

被引:13
|
作者
Tognetto, Daniele [1 ]
Pastore, Marco R. [1 ]
De Giacinto, Chiara [1 ]
Merli, Riccardo [1 ]
Franzon, Marco [2 ]
D'Aloisio, Rossella [1 ]
Belfanti, Lorenzo [1 ]
Giglio, Rosa [1 ]
Cirigliano, Gabriella [1 ]
机构
[1] Univ Trieste, Dept Med Surg Sci & Hlth, Eye Clin, I-34129 Trieste, Italy
[2] Univ Trieste, Dept Math & Comp Sci, I-34129 Trieste, Italy
关键词
MORPHOLOGY; DEVICE; EYES;
D O I
10.1038/s41598-019-46243-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this study was to assess the central macular imaging captured with an optical biometer based on full-eye-length Swept-Source OCT (SS-OCT) scan as a screening strategy for identifying macular diseases in patients scheduled for cataract surgery. 1,114 eyes of 749 consecutive patients underwent a biometrical examination with IOLMaster 700 SS-OCT technology (Carl Zeiss) and conventional Spectral-Domain OCT (SD-OCT) (Spectralis OCT, Heidelberg) device analysis on the same day. Seven examiners graded the scans individually in a full-masked mode. Twenty-five eyes were excluded for media opacities. Among the 1,089 included eyes, statistical analysis revealed a mean Kendall's Coefficient of 0.83 (range 0.76-0.89). A logistic regression model demonstrated a highly significant correlation (p < 0.001) between the coefficient of concordance and SD-OCT imaging. Intraobserver reproducibility was 0.89 (range 0.86-0.91). Optical biometer SS-OCT scans showed a mean sensitivity of 0.81 and a mean specificity of 0.84. The positive and negative predictive value detected was 0.78 and 0.86, respectively. In order to predict the risk of reduced visual recovery, especially in cases of retinal pathology, optical biometer with SS-OCT scan has proven to be a useful modality for detecting macular structural abnormalities in patients undergoing cataract surgery. Conventional SD-OCT remains mandatory to confirm the presumed diagnosis.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Advances in swept-source optical coherence tomography and optical coherence tomography angiography
    Zheng, Fang
    Deng, Xiaofeng
    Zhang, Qi
    He, Jingliang
    Ye, Panpan
    Liu, Shan
    Li, Peng
    Zhou, Jian
    Fang, Xiaoyun
    ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2023, 3 (02): : 67 - 79
  • [42] DURATION OF PRONE POSITIONING AFTER MACULAR HOLE SURGERY DETERMINED BY SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY
    Sano, Masahiko
    Inoue, Makoto
    Itoh, Yuji
    Kita, Yoshiyuki
    Hirota, Kazunari
    Koto, Takashi
    Hirakata, Akito
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (08): : 1483 - 1491
  • [43] Impact of lens opacity and axial length on concomitant screening of maculopathy by swept-source optical coherence tomography-based optical biometer
    Qin, Yingyan
    Ye, Shaobi
    Liu, Liangping
    Wu, Mingxing
    ANNALS OF TRANSLATIONAL MEDICINE, 2022, 10 (15)
  • [44] Repeatability and interobserver reproducibility of a new optical biometer based on swept-source optical coherence tomography and comparison with IOLMaster
    Huang, Jinhai
    Savini, Giacomo
    Hoffer, Kenneth J.
    Chen, Hao
    Lu, Weicong
    Hu, Qingjie
    Bao, Fangjun
    Wang, Qinmei
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (04) : 493 - 498
  • [45] Evaluation of Axial Length Measurement Using Enhanced Retina Visualization Mode of the Swept-Source Optical Coherence Tomography Biometer in Dense Cataract
    Tamaoki, Akeno
    Kojima, Takashi
    Hasegawa, Asato
    Yamamoto, Mana
    Kaga, Tatsushi
    Tanaka, Kiyoshi
    Ichikawa, Kazuo
    OPHTHALMIC RESEARCH, 2021, 64 (04) : 595 - 603
  • [46] Assessment of precision of astigmatism measurements taken by a swept-source optical coherence tomography biometer - IOLMaster 700
    Sharma, Ajay
    Batra, Akanksha
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (07) : 1760 - 1765
  • [47] Comparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer
    Chan, Tommy C. Y.
    Yu, Marco C. Y.
    Chiu, Vivian
    Lai, Gilda
    Leung, Christopher K. S.
    Chan, Poemen P. M.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [48] Comparing Predictive Accuracy of a Swept Source Optical Coherence Tomography Biometer and an Optical Low Coherence Reflectometry Biometer
    Blehm, Clayton
    Hall, Brad
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 2125 - 2131
  • [49] Biometry with a new swept-source optical coherence tomography biometer: Repeatability and agreement with an optical low-coherence reflectometry device
    Kurian, Mathew
    Negalur, Nikhil
    Das, Sudeep
    Puttaiah, Narendra K.
    Haria, Dhawal
    Tejal, S. J.
    Thakkar, Maithil M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04): : 577 - 581
  • [50] Repeatability and Agreement of a Swept-Source Optical Coherence Tomography-Based Biometer IOLMaster 700 Versus a Scheimpflug Imaging-Based Biometer AL-Scan in Cataract Patients
    Chan, Tommy C. Y.
    Wan, Kelvin H.
    Tang, Fang Yao
    Wang, Yu Meng
    Yu, Marco
    Cheung, Carol
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2020, 46 (01): : 35 - 45