Swept-Source Optical Coherence Tomography Biometer as Screening Strategy for Macular Disease in Patients Scheduled for Cataract Surgery

被引:13
|
作者
Tognetto, Daniele [1 ]
Pastore, Marco R. [1 ]
De Giacinto, Chiara [1 ]
Merli, Riccardo [1 ]
Franzon, Marco [2 ]
D'Aloisio, Rossella [1 ]
Belfanti, Lorenzo [1 ]
Giglio, Rosa [1 ]
Cirigliano, Gabriella [1 ]
机构
[1] Univ Trieste, Dept Med Surg Sci & Hlth, Eye Clin, I-34129 Trieste, Italy
[2] Univ Trieste, Dept Math & Comp Sci, I-34129 Trieste, Italy
关键词
MORPHOLOGY; DEVICE; EYES;
D O I
10.1038/s41598-019-46243-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this study was to assess the central macular imaging captured with an optical biometer based on full-eye-length Swept-Source OCT (SS-OCT) scan as a screening strategy for identifying macular diseases in patients scheduled for cataract surgery. 1,114 eyes of 749 consecutive patients underwent a biometrical examination with IOLMaster 700 SS-OCT technology (Carl Zeiss) and conventional Spectral-Domain OCT (SD-OCT) (Spectralis OCT, Heidelberg) device analysis on the same day. Seven examiners graded the scans individually in a full-masked mode. Twenty-five eyes were excluded for media opacities. Among the 1,089 included eyes, statistical analysis revealed a mean Kendall's Coefficient of 0.83 (range 0.76-0.89). A logistic regression model demonstrated a highly significant correlation (p < 0.001) between the coefficient of concordance and SD-OCT imaging. Intraobserver reproducibility was 0.89 (range 0.86-0.91). Optical biometer SS-OCT scans showed a mean sensitivity of 0.81 and a mean specificity of 0.84. The positive and negative predictive value detected was 0.78 and 0.86, respectively. In order to predict the risk of reduced visual recovery, especially in cases of retinal pathology, optical biometer with SS-OCT scan has proven to be a useful modality for detecting macular structural abnormalities in patients undergoing cataract surgery. Conventional SD-OCT remains mandatory to confirm the presumed diagnosis.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Detecting macular disease with a biometry device using swept-source optical coherence tomography Reply
    Hirnschall, Nino
    Leisser, Christoph
    Radda, Stephan
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (10): : 1545 - 1545
  • [32] "Diamond wire mesh" appearance of cataract on swept-source optical coherence tomography
    Delhiwala, K.
    Shah, K.
    Khamar, B.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (08): : 992 - 993
  • [33] Efficacy of Swept-source Optical Coherence Tomography in Axial Length Measurement for Advanced Cataract Patients
    Chirapapaisan, Chareenun
    Srivannaboon, Sabong
    Chonpimai, Pratuangsri
    OPTOMETRY AND VISION SCIENCE, 2020, 97 (03) : 186 - 191
  • [34] Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer
    Srivannaboon, Sabong
    Chirapapaisan, Chareenun
    Chonpimai, Pratuangsri
    Loket, Siriwan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10): : 2224 - 2232
  • [35] Objective quantification of posterior capsule opacification after cataract surgery with swept-source optical coherence tomography
    Zhou, Yu
    Xiang, Jing
    Xu, Fang
    Jiang, Ziyuan
    Liu, Fang
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [36] Objective quantification of posterior capsule opacification after cataract surgery with swept-source optical coherence tomography
    Yu Zhou
    Jing Xiang
    Fang Xu
    Ziyuan Jiang
    Fang Liu
    BMC Ophthalmology, 23
  • [37] Detailed Corneal Characteristics with Swept-Source Optical Coherence Tomography in Patients with Macular Corneal Dystrophy
    Nowinska, Anna
    Teper, Slawomir
    Wylegala, Edward
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [38] Assessment of macular microcirculation in patients with multiple sclerosis by swept-source optical coherence tomography angiography
    Eker, Serhat
    Karakucuk, Yalcin
    Gumus, Haluk
    MARMARA MEDICAL JOURNAL, 2024, 37 (02): : 192 - 197
  • [39] Agreement and clinical comparison between a new swept-source optical coherence tomography-based optical biometer and an optical low-coherence reflectometry biometer
    Arriola-Villalobos, P.
    Almendral-Gomez, J.
    Garzon, N.
    Ruiz-Medrano, J.
    Fernandez-Perez, C.
    Martinez-de-la-Casa, J. M.
    Diaz-Valle, D.
    EYE, 2017, 31 (03) : 437 - 442
  • [40] Agreement and clinical comparison between a new swept-source optical coherence tomography-based optical biometer and an optical low-coherence reflectometry biometer
    P Arriola-Villalobos
    J Almendral-Gómez
    N Garzón
    J Ruiz-Medrano
    C Fernández-Pérez
    J M Martínez-de-la-Casa
    D Díaz-Valle
    Eye, 2017, 31 : 437 - 442