A large-scale multicentre study of patient skin doses in interventional cardiology: dose-area product action levels and dose reference levels

被引:66
|
作者
Bogaert, E. [1 ]
Bacher, K. [1 ]
Lemmens, K. [1 ]
Carlier, M. [2 ]
Desmet, W. [3 ]
De Wagter, X. [4 ]
Djian, D. [5 ]
Hanet, C. [6 ]
Heyndrickx, G. [7 ]
Legrand, V. [8 ]
Taeymans, Y. [9 ]
Thierens, H. [1 ]
机构
[1] Univ Ghent, Dept Med Phys & Radiat Protect, B-9000 Ghent, Belgium
[2] Hop St Joseph, Dept Intervent Cardiol, Gilly, Belgium
[3] Univ Ziekenhuis Gasthuisberg, Louvain, Belgium
[4] Algemeen Ziekenhuis Maria Middelares, Ghent, Belgium
[5] Ctr Hosp Namur, Namur, Belgium
[6] Clin Univ St Luc, B-1200 Brussels, Belgium
[7] Onze Lieve Vrouw Hosp, Aalst, Belgium
[8] Ctr Hosp Univ, Liege, Belgium
[9] Univ Ziekenhuis, Ghent, Belgium
来源
BRITISH JOURNAL OF RADIOLOGY | 2009年 / 82卷 / 976期
关键词
FLUOROSCOPICALLY GUIDED PROCEDURES; CORONARY ANGIOPLASTY; RADIATION-EXPOSURE; CARDIAC PROCEDURES; INJURIES; ANGIOGRAPHY; RADIOLOGY; CATHETERIZATION; VALUES;
D O I
10.1259/bjr/29449648
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For 318 patients in 8 different Belgian hospitals, the entire skin-dose distribution was mapped using a grid of 70 thermoluminescence dosemeters per patient, allowing an accurate determination of the maximum skin dose (MSD). Dose-area product (DAP) values, exposure parameters and geometry, together with procedure, patient and cardiologist characteristics, were also registered. Procedures were divided into two groups: diagnostic procedures (coronary angiography) and therapeutic procedures (dilatation, stent, combined procedures (e.g. coronary angiography + dilatation + stent)). The mean value of the MSD was 0.310 Gy for diagnostic and 0.699 Gy for therapeutic procedures. The most critical projection for receiving the MSD is the LAO90 (left anterior oblique) geometry. In 3% of cases, the MSD exceeded the 2 Gy dose threshold for deterministic effects. Action levels in terms of DAP values as the basis for a strategy for follow-up of patients for deterministic radiation skin effects were derived from measured MSD and cumulative DAP values. Two DAP action levels are proposed. A first DAP action level of 125 Gy cm(2) corresponding to the dose threshold of 2 Gy would imply an optional radiopathological follow-up depending on the cardiologist's decision. A second DAP action level of 250 Gy cm(2) corresponding to the 3 Gy skin dose would imply a systematic follow-up. Dose reference levels - 71.3 Gy cm(2) for diagnostic and 106.0 Gy cm(2) for therapeutic procedures - were derived from the 75 percentile of the DAP distributions. As a conclusion, we propose that total DAP is registered in patient's record file, as it can serve to improve the follow-up of. patients for radiation-induced skin injuries.
引用
收藏
页码:303 / 312
页数:10
相关论文
共 45 条
  • [1] Skin dose and dose-area product values for interventional cardiology procedures
    Vano, E
    Gonzalez, L
    Ten, JI
    Fernandez, JM
    Guibelalde, E
    Macaya, C
    BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (877): : 48 - 55
  • [2] Correlation of patient skin doses in cardiac interventional radiology with dose-area product
    van de Putte, S
    Verhaegen, F
    Taeymans, Y
    Thierens, H
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (869): : 504 - 513
  • [3] A large-scale multicentre study in Belgium of dose area product values and effective doses in interventional cardiology using contemporary X-ray equipment
    Bogaert, E.
    Bacher, K.
    Thierens, H.
    RADIATION PROTECTION DOSIMETRY, 2008, 128 (03) : 312 - 323
  • [4] SCATTER AND STAFF DOSE LEVELS IN PAEDIATRIC INTERVENTIONAL CARDIOLOGY: A MULTICENTRE STUDY
    Ubeda, Carlos
    Vano, Eliseo
    Gonzalez, Luciano
    Miranda, Patricia
    Valenzuela, Edith
    Leyton, Fernando
    Oyarzun, Carlos
    RADIATION PROTECTION DOSIMETRY, 2010, 140 (01) : 67 - 74
  • [5] Reference levels and patient doses in interventional cardiology procedures in Greece
    Simantirakis, George
    Koukorava, Christina
    Kalathaki, Maria
    Pafilis, Christos
    Kaisas, Ioannis
    Economides, Sotirios
    Hourdakis, Costas J.
    Kamenopoulou, Vassiliki
    Georgiou, Evaggelos
    EUROPEAN RADIOLOGY, 2013, 23 (08) : 2324 - 2332
  • [6] Reference levels and patient doses in interventional cardiology procedures in Greece
    George Simantirakis
    Christina Koukorava
    Maria Kalathaki
    Christos Pafilis
    Ioannis Kaisas
    Sotirios Economides
    Costas J. Hourdakis
    Vassiliki Kamenopoulou
    Evaggelos Georgiou
    European Radiology, 2013, 23 : 2324 - 2332
  • [7] Entrance skin dose estimates derived from dose-area product measurements in interventional radiological procedures
    McParland, BJ
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (852): : 1288 - 1295
  • [8] Dose area product measurement for diagnostic reference levels and analysis of patient dose in dental radiography
    Han, Suchul
    Lee, Boram
    Shin, Gwisoon
    Choi, Jonghak
    Kim, Jungmin
    Park, Changseo
    Park, Hyok
    Lee, Kisung
    Kim, Youhyun
    RADIATION PROTECTION DOSIMETRY, 2012, 150 (04) : 523 - 531
  • [9] Patient Dose Reference Levels for Interventional Radiology: A National Approach
    Vano, Eliseo
    Sanchez, R.
    Fernandez, J. M.
    Gallego, J. J.
    Verdu, J. F.
    Gonzalez de Garay, M.
    Azpiazu, A.
    Segarra, A.
    Hernandez, M. T.
    Canis, M.
    Diaz, F.
    Moreno, F.
    Palmero, J.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (01) : 19 - 24
  • [10] Patient Dose Reference Levels for Interventional Radiology: A National Approach
    Eliseo Vano
    R. Sanchez
    J. M. Fernandez
    J. J. Gallego
    J. F. Verdu
    M. Gonzalez de Garay
    A. Azpiazu
    A. Segarra
    M. T. Hernandez
    M. Canis
    F. Diaz
    F. Moreno
    J. Palmero
    CardioVascular and Interventional Radiology, 2009, 32 : 19 - 24