A large-scale multicentre study of patient skin doses in interventional cardiology: dose-area product action levels and dose reference levels

被引:66
|
作者
Bogaert, E. [1 ]
Bacher, K. [1 ]
Lemmens, K. [1 ]
Carlier, M. [2 ]
Desmet, W. [3 ]
De Wagter, X. [4 ]
Djian, D. [5 ]
Hanet, C. [6 ]
Heyndrickx, G. [7 ]
Legrand, V. [8 ]
Taeymans, Y. [9 ]
Thierens, H. [1 ]
机构
[1] Univ Ghent, Dept Med Phys & Radiat Protect, B-9000 Ghent, Belgium
[2] Hop St Joseph, Dept Intervent Cardiol, Gilly, Belgium
[3] Univ Ziekenhuis Gasthuisberg, Louvain, Belgium
[4] Algemeen Ziekenhuis Maria Middelares, Ghent, Belgium
[5] Ctr Hosp Namur, Namur, Belgium
[6] Clin Univ St Luc, B-1200 Brussels, Belgium
[7] Onze Lieve Vrouw Hosp, Aalst, Belgium
[8] Ctr Hosp Univ, Liege, Belgium
[9] Univ Ziekenhuis, Ghent, Belgium
来源
BRITISH JOURNAL OF RADIOLOGY | 2009年 / 82卷 / 976期
关键词
FLUOROSCOPICALLY GUIDED PROCEDURES; CORONARY ANGIOPLASTY; RADIATION-EXPOSURE; CARDIAC PROCEDURES; INJURIES; ANGIOGRAPHY; RADIOLOGY; CATHETERIZATION; VALUES;
D O I
10.1259/bjr/29449648
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For 318 patients in 8 different Belgian hospitals, the entire skin-dose distribution was mapped using a grid of 70 thermoluminescence dosemeters per patient, allowing an accurate determination of the maximum skin dose (MSD). Dose-area product (DAP) values, exposure parameters and geometry, together with procedure, patient and cardiologist characteristics, were also registered. Procedures were divided into two groups: diagnostic procedures (coronary angiography) and therapeutic procedures (dilatation, stent, combined procedures (e.g. coronary angiography + dilatation + stent)). The mean value of the MSD was 0.310 Gy for diagnostic and 0.699 Gy for therapeutic procedures. The most critical projection for receiving the MSD is the LAO90 (left anterior oblique) geometry. In 3% of cases, the MSD exceeded the 2 Gy dose threshold for deterministic effects. Action levels in terms of DAP values as the basis for a strategy for follow-up of patients for deterministic radiation skin effects were derived from measured MSD and cumulative DAP values. Two DAP action levels are proposed. A first DAP action level of 125 Gy cm(2) corresponding to the dose threshold of 2 Gy would imply an optional radiopathological follow-up depending on the cardiologist's decision. A second DAP action level of 250 Gy cm(2) corresponding to the 3 Gy skin dose would imply a systematic follow-up. Dose reference levels - 71.3 Gy cm(2) for diagnostic and 106.0 Gy cm(2) for therapeutic procedures - were derived from the 75 percentile of the DAP distributions. As a conclusion, we propose that total DAP is registered in patient's record file, as it can serve to improve the follow-up of. patients for radiation-induced skin injuries.
引用
收藏
页码:303 / 312
页数:10
相关论文
共 45 条
  • [21] A national patient dose survey and setting of reference levels for interventional radiology in Bulgaria
    Zotova, R.
    Vassileva, J.
    Hristova, J.
    Pirinen, M.
    Jarvinen, H.
    EUROPEAN RADIOLOGY, 2012, 22 (06) : 1240 - 1249
  • [22] A national patient dose survey and setting of reference levels for interventional radiology in Bulgaria
    R. Zotova
    J. Vassileva
    J. Hristova
    M. Pirinen
    H. Järvinen
    European Radiology, 2012, 22 : 1240 - 1249
  • [23] Establishment of local diagnostic reference levels for radiation dose in paediatric interventional cardiology procedures in Brazil
    Yagui, Akemi
    Schelin, Hugo
    Mello, Rosiane
    Andrade, Diancarlos
    Vosiak, Paula
    Denyak, Valeriy
    Filipov, Danielle
    Paschuk, Sergei
    Khoury, Helen
    Ubeda, Carlos
    RADIATION PHYSICS AND CHEMISTRY, 2024, 218
  • [24] Dose levels from thoracic and pelvic examinations in two pediatric radiological departments in Norway - a comparison study of dose-area product and radiographic technique
    Saether, Hilde Kjernlie
    Lagesen, Bente
    Martinsen, Anne Catrine Traegde
    Holsen, Eva Platou
    Ovrebo, Kirsti Marie
    ACTA RADIOLOGICA, 2010, 51 (10) : 1137 - 1142
  • [25] A PHANTOM BASED METHOD FOR DERIVING TYPICAL PATIENT DOSES FROM MEASUREMENTS OF DOSE-AREA PRODUCT ON POPULATIONS OF PATIENTS
    CHAPPLE, CL
    BROADHEAD, DA
    FAULKNER, K
    BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (814): : 1083 - 1086
  • [26] Correction to: Patient dose reference levels in surgery: a multicenter study
    J. Greffier
    C. Etard
    O. Mares
    F. Pereira
    D. Defez
    C. Duverger
    P. Branchereau
    J. P. Beregi
    R. Coulomb
    A. Larbi
    European Radiology, 2019, 29 : 1635 - 1636
  • [27] PATIENT DOSE FOR COMPUTED TOMOGRAPHY EXAMINATION: DOSE REFERENCE LEVELS AND EFFECTIVE DOSES BASED ON A NATIONAL SURVEY OF 2013 IN KOREA
    Kim, Moon Chan
    Han, Dong Kyoon
    Nam, Yoon Chul
    Kim, Yon Min
    Yoon, Joon
    RADIATION PROTECTION DOSIMETRY, 2015, 164 (03) : 383 - 391
  • [28] A preliminary study to determine the diagnostic reference level using dose-area product for limited-area cone beam CT
    Endo, A.
    Katoh, T.
    Vasudeva, S. B.
    Kobayashi, I.
    Okano, T.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (04)
  • [29] An audit of patient radiation doses during interventional cardiology procedures in Uttarakhand, India, and establishment of local diagnostic reference levels
    Uniyal, Satish C.
    Singh, Vikram
    Rawat, Anurag
    Gururani, Kunal
    Belwal, Chandra Mohan
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (02) : 476 - 487
  • [30] Patient radiation doses in interventional cardiology in the US: Advisory data sets and possible initial values for US reference levels
    Miller, Donald L.
    Hilohi, C. Michael
    Spelic, David C.
    MEDICAL PHYSICS, 2012, 39 (10) : 6276 - 6286