Entrance skin dose estimates derived from dose-area product measurements in interventional radiological procedures

被引:98
|
作者
McParland, BJ [1 ]
机构
[1] King Fahad Natl Guard Hosp, Dept Med Imaging, Riyadh 11426, Saudi Arabia
来源
BRITISH JOURNAL OF RADIOLOGY | 1998年 / 71卷 / 852期
关键词
D O I
10.1259/bjr.71.852.10319003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Patient skin doses resulting from interventional radiological procedures have the potential to exceed threshold doses for deterministic effects such as erythema and epilation. If the irradiation geometry is known, the entrance skin dose can be estimated fl om the measured dose-area product. For each of 10 non-coronary interventional procedures, a nominal geometry was identified. From a previous survey of patient dose-area products, the entrance skin doses were estimated under the assumption that all procedures were performed with the nominal geometry specific to it. An analysis of the uncertainties in these doses caused by realistic deviations from the nominal geometry was also performed and it was shown that the estimated entrance skin dose values are at least to within 40%, and generally to within about 30%, of those actually received. For example, the median estimated entrance skin doses for the posteroanterior and lateral projections of cerebral angiography were 100 and 110 mGy, respectively, and for hepatic angiography 425 mGy. The largest entrance skin dose estimate for a single projection was for the angiography component of a CT arterial portography procedure at 670 mGy. Comparisons between entrance skin dose estimates obtained from this study are made with data from other interventional radiology patient dose surveys.
引用
收藏
页码:1288 / 1295
页数:8
相关论文
共 50 条
  • [1] Entrance skin dose using dose-area product measurements
    Adnani, N
    MEDICAL PHYSICS, 2003, 30 (07) : 1951 - 1951
  • [2] Skin dose and dose-area product values for interventional cardiology procedures
    Vano, E
    Gonzalez, L
    Ten, JI
    Fernandez, JM
    Guibelalde, E
    Macaya, C
    BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (877): : 48 - 55
  • [3] Entrance skin dose using dose-area product measurements: Application to a cardiac catheterization laboratory
    Adnani, N
    MEDICAL PHYSICS, 2003, 30 (06) : 1381 - 1381
  • [4] Estimation of effective dose in diagnostic radiology from entrance surface dose and dose-area product measurements
    Wade, JP
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (849): : 994 - 994
  • [5] Differences in effective dose estimation from dose-area product and entrance surface dose measurements in intravenous urography
    Yakoumakis, E
    Tsalafoutas, IA
    Nikolaou, D
    Nazos, I
    Koulentianos, E
    Proukakis, C
    BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (884): : 727 - 734
  • [6] Estimation of effective dose in diagnostic radiology from entrance surface dose and dose-area product measurements - Reply
    Hart, D
    Jones, D
    Wall, B
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (849): : 995 - 995
  • [7] Relationships between entrance skin dose, effective dose and dose area product for patients in diagnostic and interventional cardiac procedures
    Hansson, B
    Karambatsakidou, A
    RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 141 - 144
  • [8] The dose-area product and assessment of the occupational dose in interventional radiology
    Servomaa, A
    Karppinen, J
    RADIATION PROTECTION DOSIMETRY, 2001, 96 (1-3) : 235 - 236
  • [9] Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures
    Chida, K
    Saito, H
    Otani, H
    Kohzuki, M
    Takahashi, S
    Yamada, S
    Shirato, K
    Zuguchi, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (03) : 774 - 778
  • [10] Dose-area product measurements during angiographic X ray procedures
    Mini, RL
    Schmid, B
    Schneeberger, P
    Vock, P
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 145 - 148