Monte-Carlo dosimetry for intraoperative radiotherapy using a low energy x-ray source

被引:22
|
作者
Bouzid, Dounia [1 ,2 ]
Bert, Julien [1 ]
Dupre, Pierre-Francois [3 ]
Benhalouche, Saadia [1 ]
Pradier, Olivier [1 ,2 ]
Boussion, Nicolas [1 ,2 ]
Visvikis, Dimitris [1 ]
机构
[1] INSERM, UMR1101, LaTIM, Brest, France
[2] CHRU Brest, Dept Radiotherapy, Brest, France
[3] CHRU Brest, Dept Gynecol & Surg, Brest, France
关键词
DOSE CALCULATION; BRACHYTHERAPY; TARGIT; GPU; RADIOSURGERY; SIMULATIONS; PARAMETERS; MINIATURE; MODEL; CT;
D O I
10.3109/0284186X.2015.1016623
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Intraoperative radiotherapy (IORT) is continuously gaining ground in cancer treatment. However, there is currently no planning system associated with these devices, which precludes patient-specific dose delivery optimization. The objective of this study was the development and validation of a Monte Carlo simulation (MCS)-based dosimetry platform using the Intrabeam system.Methods. After surgical resection of the tumor this system delivers a single dose fraction at the surface of an applicator irradiating the tumor bed through a 50 kV x-ray beam. The GATE MCS platform was used in this study combining the phase space obtained by modeling the x-ray source and the detailed modeling of the additional parts of the Intrabeam system. The model was validated by comparing simulated versus experimental measurements of depth dose curves (DDC) and isotropy. A clinical validation study was also carried out using patient computed tomography images.Results. The mean deviation between measured and simulated DDC was 2.9% 4.4% and 5.9% +/- 5.7% for the bare needle and the use of applicators, respectively. A good agreement with experimental measurements was also found in terms of dose isotropy with a maximum difference of 2.04% for the 40 mm diameter applicator. A patient study revealed a mean absolute deviation of 0.06 Gy between simulated and thermoluminescent dosimeters (TLD) measured skin doses.Conclusion. This study shows the potential of using the GATE MCS platform to model three-dimensional dose distributions of the Intrabeam system for use in IORT.
引用
收藏
页码:1788 / 1795
页数:8
相关论文
共 50 条
  • [31] Monte-Carlo simulation of x-ray photoelectron emission from silver
    Zhang, Z
    Koshikawa, T
    Iyasu, T
    Shimizu, R
    Goto, K
    Tanaka, A
    [J]. SURFACE AND INTERFACE ANALYSIS, 2003, 35 (10) : 818 - 823
  • [32] A phase II study of intraoperative radiotherapy using a low-energy x-ray source for resectable pancreatic cancer: a study protocol
    Jun Won Kim
    Yeona Cho
    Hyung Sun Kim
    Won Hoon Choi
    Joon Seong Park
    Ik Jae Lee
    [J]. BMC Surgery, 19
  • [33] A phase II study of intraoperative radiotherapy using a low-energy x-ray source for resectable pancreatic cancer: a study protocol
    Kim, Jun Won
    Cho, Yeona
    Kim, Hyung Sun
    Choi, Won Hoon
    Park, Joon Seong
    Lee, Ik Jae
    [J]. BMC SURGERY, 2019, 19 (1)
  • [34] Monte Carlo simulation of X-ray spectra from low energy electrons using optical data
    Roet, D.
    Van Espen, P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (17-18): : 2794 - 2800
  • [35] MONTE-CARLO STUDIES OF IMAGE SPREAD BY X-RAY INTENSIFYING SCREENS
    CARUTHERS, E
    [J]. PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 535 : 140 - 147
  • [36] X-ray scattering in X-ray fluorescence spectra with X-ray tube excitation - Modelling, experiment, and Monte-Carlo simulation
    Hodoroaba, V. -D.
    Radtke, M.
    Vincze, L.
    Rackwitz, V.
    Reuter, D.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (24): : 3568 - 3575
  • [37] A portable organic plastic scintillator dosimetry system for low energy X-rays: A feasibility study using an intraoperative X-ray unit as the radiation source
    Williams, Kerry
    Robinson, Neil
    Trapp, Jamie
    Ackerly, Trevor
    Das, Ram
    Kemp, Penny
    Geso, Moshi
    [J]. JOURNAL OF MEDICAL PHYSICS, 2007, 32 (02) : 73 - 76
  • [38] Experimental benchmarking of Monte Carlo simulations for radiotherapy dosimetry using monochromatic X-ray beams in the presence of metal-based compounds
    Spiga, Jenny
    Pellicioli, Paolo
    Manger, Sam P.
    Duffy, Jon A.
    Bravin, Alberto
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 66 : 45 - 54
  • [39] STUDIES OF X-RAY-ENERGY ABSORPTION AND QUANTUM NOISE PROPERTIES OF X-RAY SCREENS BY USE OF MONTE-CARLO SIMULATION
    CHAN, HP
    DOI, K
    [J]. MEDICAL PHYSICS, 1984, 11 (01) : 37 - 46
  • [40] Modeling of radiotherapy x-ray sources for Monte Carlo treatment planning
    Garnica-Garza, H
    Van den Heuvel, F
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1352 - 1352