Improving the spatial resolution and image noise in densely pixilated detectors for positron emission mammography

被引:0
|
作者
Hinse, MJ [1 ]
Thompson, CJ [1 ]
机构
[1] McGill Univ, Dept Phys Med, Montreal, PQ H3G 1A4, Canada
关键词
D O I
10.1109/NSSMIC.2003.1352378
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Sampling artifacts are introduced in positron emission mammography (PEM) from the use of discrete crystals which form planar stationary detectors. With the breast positioned in between the two detectors, the images are reconstructed by back-projecting lines of response (LORs) onto seven, equally spaced, virtual image planes. LORs are assumed to start and end on a unique point, the centroid of interaction within each crystal. This limits the sampling of the image space and introduces grid like sampling artifacts due to the variable density of LORs that intersect each pixel in the image. When using crystals that are very densely pixilated, as it is the case in PEM, the regions associated with each crystal in the crystal identification matrix may overlap. We postulate that allowing the LORs to shift away from the centroid, according to their relative position in the region, should reduce sampling artifacts. The solid angle function is an image uniformity correction function. It corrects for the varying geometrical efficiencies of image pixels. The solid angle function is the last thing applied before the images are displayed. We postulate that re-ordering the solid angle function and the smoothing algorithm should improve image quality. Reformatting data from contrast resolution and point source phantom studies with the new strategies showed no or very few sampling artifacts. More than half of the 15 cases studied showed an improvement of 50% in signal-to-noise ratio, 2% in spatial resolution, and a reduction of 25% of the noise, despite a 3% loss in contrast resolution. When clinical PEM images were reformatted with the new strategies they showed no sampling artifacts and were smoother.
引用
收藏
页码:2396 / 2400
页数:5
相关论文
共 50 条
  • [1] Improving the spatial resolution and image noise in densely pixilated detectors for positron emission mammography
    Hinse, MJ
    Thompson, CJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 676 - 683
  • [2] Image enhancement in positron emission mammography
    Slavine, Nikolai V.
    Seiler, Stephen
    McColl, Roderick W.
    Lenkinski, Robert E.
    [J]. MEDICAL IMAGING 2017: IMAGE PROCESSING, 2017, 10133
  • [3] Correction of spatial distortion, gain nonuniformity and efficiency variation in detectors for positron emission mammography
    Robar, JL
    Thompson, CJ
    Murthy, K
    Clancy, RL
    Bergman, AM
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1206 - 1210
  • [4] Image improvement method for positron emission mammography
    Slavine, Nikolai V.
    Seiler, Stephen J.
    McColl, Roderick W.
    Lenkinski, Robert E.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 39 : 164 - 173
  • [5] Targeted Image Reconstruction in Positron Emission Mammography
    Picado, G.
    Matela, N.
    Oliveira, N.
    Almeida, P.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 5, 2009, 25 : 358 - 361
  • [6] Data acquisition electronics for positron emission mammography (PEM) detectors
    Martínez, JD
    Sebastiá, A
    Cerdá, J
    Esteve, R
    Mora, FJ
    Toledo, JF
    Benlloch, JM
    Giménez, N
    Giménez, M
    Lerche, CW
    Pavón, N
    Sánchez, F
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 537 (1-2): : 335 - 338
  • [7] Detectors with Dual-Ended Readout by Silicon Photomultipliers for High Resolution Positron Emission Mammography Applications
    Taghibakhsh, Farhad
    Cuddy, Sarah
    Rvachov, Timur
    Green, David
    Reznik, Alla
    Rowlands, John A.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2821 - +
  • [8] Evaluation of a high resolution positron emission tomography (PET) scanner for positron emission mammography (PEM)
    White, LL
    Ott, RJ
    Carnochan, P
    Duxbury, DM
    Bruyndonckx, P
    Tavernier, S
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1236 - 1240
  • [9] A positron emission mammography system based on 4 mm straw detectors
    Sun, Liang
    Martin, Christopher S.
    Athanasiades, Athanasios
    Lyons, Thomas D.
    Lacy, Jeffrey L.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3337 - 3344
  • [10] Positron Emission Mammography Image Interpretation for Reduced Image Count Levels
    MacDonald, Lawrence R.
    Hippe, Daniel S.
    Bender, Leila C.
    Cotter, Elizabeth W.
    Voria, Pooja R.
    Hallam, Paula S.
    Wang, Carolyn L.
    Haseley, David R.
    Kelly, Mary M.
    Parikh, Jay R.
    Beatty, J. David
    Rogers, James V.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (03) : 348 - 354