Correction of spatial distortion, gain nonuniformity and efficiency variation in detectors for positron emission mammography

被引:0
|
作者
Robar, JL
Thompson, CJ
Murthy, K
Clancy, RL
Bergman, AM
机构
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Each of two detectors used in our Positron Emission Mammography (PEM) system consists of four 36mm x 36mm x 20mm bismuth germanate (EGO) crystal detector blocks coupled to a crossed-wire anode position-sensitive photomultiplier tube (PS-PMT). To facilitate high spatial-resolution imaging, the crystal blocks have been pixellated into small elements on two opposite faces. In total, there are 71 x 71 elements on each detector. In order to improve the quality of images obtained using this system, we have identified three required aspects of detector calibration. First, in order to correct for spatial distortion inherent in the detectors, an accurate method for crystal element identification has been developed. This algorithm successfully identifies 59 x 49 crystal elements, and these results are used to generate a distortion Look-Up-Table (LUT). Second, corrections for a marked spatial variation of detector gain are required in order to facilitate accurate energy discrimination. This variation is quantitated by generating energy spectra specific to each of the identified crystal elements, and recording the relative gain of each element in an energy LUT. Finally, by using a third LUT containing the relative efficiencies of crystal elements, the flood-image nonuniformity has been reduced from 50% to 13%.
引用
收藏
页码:1206 / 1210
页数:5
相关论文
共 34 条
  • [1] Shutterless Method for Gain Nonuniformity Correction of Microbolometer Detectors
    Olbrycht, Robert
    Wiecek, Boguslaw
    Swiatczak, Tomasz
    [J]. MIXDES 2009: PROCEEDINGS OF THE 16TH INTERNATIONAL CONFERENCE MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2009, : 378 - 380
  • [2] Shutterless method for gain nonuniformity correction of microbolometer detectors
    Olbrycht, Robert
    Wiecek, Boguslaw
    Swiatczak, Tomasz
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (11A): : 120 - 122
  • [3] Scatter correction for positron emission mammography
    Qi, JY
    Huesman, RH
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (15): : 2759 - 2771
  • [4] Improving the spatial resolution and image noise in densely pixilated detectors for positron emission mammography
    Hinse, MJ
    Thompson, CJ
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2396 - 2400
  • [5] Improving the spatial resolution and image noise in densely pixilated detectors for positron emission mammography
    Hinse, MJ
    Thompson, CJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 676 - 683
  • [6] Nonuniformity Distortion Correction of Spatial Heterodyne Continuous Light
    Wang Runhao
    Sun Yingru
    Gan Yinlu
    Wu Xingjiang
    Ke Junjie
    Wang Xinqiang
    Gan Yongying
    [J]. LASER & OPTOELECTRONICS PROGRESS, 2022, 59 (19)
  • [7] Data acquisition electronics for positron emission mammography (PEM) detectors
    Martínez, JD
    Sebastiá, A
    Cerdá, J
    Esteve, R
    Mora, FJ
    Toledo, JF
    Benlloch, JM
    Giménez, N
    Giménez, M
    Lerche, CW
    Pavón, N
    Sánchez, F
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 537 (1-2): : 335 - 338
  • [8] CORRECTION FOR FIELD NONUNIFORMITY IN SCINTILLATION CAMERAS THROUGH REMOVAL OF SPATIAL DISTORTION
    MUEHLLEHNER, G
    COLSHER, JG
    STOUB, EW
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1980, 21 (08) : 771 - 776
  • [9] A new method for the correction of gamma camera nonuniformity due to spatial distortion
    Johnson, TK
    Nelson, C
    Kirch, DL
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (10): : 2179 - 2188
  • [10] A positron emission mammography system based on 4 mm straw detectors
    Sun, Liang
    Martin, Christopher S.
    Athanasiades, Athanasios
    Lyons, Thomas D.
    Lacy, Jeffrey L.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3337 - 3344