Performance of refocusing mirrors for a soft X-ray photochemistry beamline BL27SU of SPring-8

被引:0
|
作者
Ohashi, H [1 ]
Tamenori, Y [1 ]
Ishiguro, E [1 ]
Ishikawa, T [1 ]
机构
[1] JASRI, SPring 8, Mikazuki, Hyogo 6795198, Japan
来源
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Refocusing mirrors were designed and equipped in the high-resolution branch of BL27SU in SPring-8. It is required to switch quickly among the three tandem end-stations and achieve a vertical size of less than 10 microns at one experimental station. Two toroidal mirrors and a set of two cylindrical mirrors were employed in order to align them easily. The beam size and photon flux were measured.
引用
收藏
页码:756 / 759
页数:4
相关论文
共 50 条
  • [41] First results from the actinide science beamline BL23SU at SPring-8
    Saitoh, Y
    Nakatani, T
    Matsushita, T
    Agui, A
    Yoshigoe, A
    Teraoka, Y
    Yokoya, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 474 (03): : 253 - 258
  • [42] Hard X-ray Photoelectron Spectroscopy Equipment Developed at Beamline BL46XU of SPring-8 for Industrial Researches
    Yasuno, Satoshi
    Oji, Hiroshi
    Koganezawa, Tomoyuki
    Watanabe, Takeshi
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [43] X-ray magnetic spectroscopy at high pressure: performance of SPring-8 BL39XU
    Kawamura, Naomi
    Ishimatsu, Naoki
    Maruyama, Hiroshi
    JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 : 730 - 736
  • [44] Development of a soft X-ray magnetic circular dichroism spectrometer using a 1.9T electromagnet at BL25SU of SPring-8
    Nakamura, T
    Muro, T
    Guo, FZ
    Matsushita, T
    Wakita, T
    Hirono, T
    Takeuchi, Y
    Kobayashi, K
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2005, 144 : 1035 - 1038
  • [45] SPring-8 standard x-ray monochromators
    Yabashi, M
    Yamazaki, H
    Tamasaku, K
    Goto, S
    Takeshita, K
    Mochizuki, T
    Yoneda, Y
    Furukawa, Y
    Ishikawa, T
    X-RAY OPTICS DESIGN, PERFORMANCE, AND APPLICATIONS, 1999, 3773 : 2 - 13
  • [46] A hard X-ray nanospectroscopy station at SPring-8 BL39XU
    Suzuki, M.
    Kawamura, N.
    Mizumaki, M.
    Terada, Y.
    Uruga, T.
    Fujiwara, A.
    Yamazaki, H.
    Yumoto, H.
    Koyama, T.
    Senba, Y.
    Takeuchi, T.
    Ohashi, H.
    Nariyama, N.
    Takeshita, K.
    Kimura, H.
    Matsushita, T.
    Furukawa, Y.
    Ohata, T.
    Kondo, Y.
    Ariake, J.
    Richter, J.
    Fons, P.
    Sekizawa, O.
    Ishiguro, N.
    Tada, M.
    Goto, S.
    Yamamoto, M.
    Takata, M.
    Ishikawa, T.
    15TH INTERNATIONAL CONFERENCE ON X-RAY ABSORPTION FINE STRUCTURE (XAFS15), 2013, 430
  • [47] Spectromicroscopy using an x-ray microprobe at SPring-8 BL39XU
    Hayakawa, S
    Hirokawa, T
    Gohshi, Y
    Suzuki, M
    Goto, S
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 92 - 97
  • [48] Countermeasures for X-ray intensity fluctuation on BL11XU at SPring-8
    Kiriyama, K.
    Shiwaku, H.
    Mochizuki, T.
    Shobu, T.
    Tozawa, K.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 959 - +
  • [49] Generation of an X-ray microbeam for spectromicroscopy at SPring-8 BL39XU
    Hayakawa, S
    Ikuta, N
    Suzuki, M
    Wakatsuki, M
    Hirokawa, T
    JOURNAL OF SYNCHROTRON RADIATION, 2001, 8 (02) : 328 - 330
  • [50] Atmospheric coherent X-ray diffraction imaging for in situ structural analysis at SPring-8 Hyogo beamline BL24XU
    Takayama, Yuki
    Takami, Yuki
    Fukuda, Keizo
    Miyagawa, Takamasa
    Kagoshima, Yasushi
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 1229 - 1237