A hard X-ray nanospectroscopy station at SPring-8 BL39XU

被引:23
|
作者
Suzuki, M. [1 ,2 ]
Kawamura, N. [1 ]
Mizumaki, M. [1 ]
Terada, Y. [1 ]
Uruga, T. [1 ]
Fujiwara, A. [1 ]
Yamazaki, H. [1 ,2 ]
Yumoto, H. [1 ,2 ]
Koyama, T. [1 ,2 ]
Senba, Y. [1 ,2 ]
Takeuchi, T. [1 ,2 ]
Ohashi, H. [1 ,2 ]
Nariyama, N. [1 ,2 ]
Takeshita, K. [1 ,2 ]
Kimura, H. [1 ,2 ]
Matsushita, T. [1 ,2 ]
Furukawa, Y. [1 ,2 ]
Ohata, T. [1 ,2 ]
Kondo, Y.
Ariake, J. [3 ]
Richter, J. [4 ]
Fons, P. [4 ]
Sekizawa, O. [5 ]
Ishiguro, N. [6 ]
Tada, M. [6 ]
Goto, S. [1 ,2 ]
Yamamoto, M. [1 ,2 ]
Takata, M. [1 ,2 ]
Ishikawa, T. [1 ,2 ]
机构
[1] JASRI SPring 8, Sayo, Hyogo 6795198, Japan
[2] RIKEN SPring 8 Ctr, Mikazuki, Hyogo 6795148, Japan
[3] Akita Ind Technol Ctr, Akita 0101623, Japan
[4] AIST, Tsukuba, Ibaraki 3058568, Japan
[5] Univ Electro Commun, Tokyo 1828585, Japan
[6] Inst Mol Sci, Okazaki, Aichi 4448585, Japan
关键词
D O I
10.1088/1742-6596/430/1/012017
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
We upgraded the hard X-ray spectroscopy beamline BL39XU at SPring-8 by installing Kirkpatrick-Baez mirrors to equip it with submicron-focusing capability. At the new experimental end-station located 74 m from the undulator source, an X-ray nanoprobe with a size of 120 x 100 nm(2) has become available at 5-16 keV. This upgrade is fully compatible with the X-ray polarization tunability and helicity-switching between right- and left-circular polarizations; these are unique features of the beamline, which is equipped with a diamond X-ray phase retarder. A spatial resolution of approximate to 100 nm for X-ray absorption fine structure and X-ray magnetic circular dichroism (XMCD) spectroscopy has been achieved. We show a magnetization reversal process of an individual magnetic dot in bit-patterned perpendicular recording media using element-specific XMCD magnetization measurements to demonstrate the performance of the new station.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Spectromicroscopy using an x-ray microprobe at SPring-8 BL39XU
    Hayakawa, S
    Hirokawa, T
    Gohshi, Y
    Suzuki, M
    Goto, S
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 92 - 97
  • [2] Generation of an X-ray microbeam for spectromicroscopy at SPring-8 BL39XU
    Hayakawa, S
    Ikuta, N
    Suzuki, M
    Wakatsuki, M
    Hirokawa, T
    JOURNAL OF SYNCHROTRON RADIATION, 2001, 8 (02) : 328 - 330
  • [3] X-ray magnetic spectroscopy at high pressure: performance of SPring-8 BL39XU
    Kawamura, Naomi
    Ishimatsu, Naoki
    Maruyama, Hiroshi
    JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 : 730 - 736
  • [4] X-ray microprobe system for XRF analysis and spectroscopy at SPring-8 BL39XU
    Hayakawa, S
    Goto, S
    Shoji, T
    Yamada, E
    Gohshi, Y
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 1114 - 1116
  • [5] Upgrade status of hard X-ray 100-nm probe beamlines BL37XU and BL39XU at SPring-8
    Koyama, Takahisa
    Yumoto, Hirokatsu
    Terada, Yasuko
    Suzuki, Motohiro
    Kawamura, Naomi
    Mizumaki, Masaichiro
    Nariyama, Nobuteru
    Matsushita, Tomohiro
    Ishizawa, Yasuhide
    Furukawa, Yukito
    Ohata, Toru
    Yamazaki, Hiroshi
    Takeuchi, Tomoyuki
    Senba, Yasunori
    Matsuzaki, Yasuhisa
    Tanaka, Masayuki
    Shimizu, Yasuhiro
    Kishimoto, Hikaru
    Miura, Takanori
    Kimura, Hiroaki
    Takeshita, Kunikazu
    Ohashi, Haruhiko
    Yamamoto, Masaki
    Goto, Shunji
    Takata, Masaki
    Ishikawa, Tetsuya
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS VI, 2011, 8139
  • [6] A wavelength dispersive X-ray spectrometer for small area X-ray fluorescence spectroscopy at SPring-8 BL39XU
    Hayakawa, S
    Yamaguchi, A
    Hong, W
    Gohshi, Y
    Yamamoto, T
    Hayashi, K
    Kawai, J
    Goto, S
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (01) : 171 - 177
  • [7] Polarization tunability and analysis for observing magnetic effects on BL39XU at SPring-8
    Maruyama, H
    Suzuki, M
    Kawamura, N
    Ito, M
    Arakawa, E
    Kokubun, J
    Hirano, K
    Horie, K
    Uemura, S
    Hagiwara, K
    Mizumaki, M
    Goto, S
    Kitamura, H
    Namikawa, K
    Ishikawa, T
    JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 : 1133 - 1137
  • [8] Development of hard X-ray photoelectron spectroscopy at BL29XU in SPring-8
    Takata, Y
    Yabashi, M
    Tamasaku, K
    Nishino, Y
    Miwa, D
    Ishikawa, T
    Ikenaga, E
    Horiba, K
    Shin, S
    Arita, M
    Shimada, K
    Namatame, H
    Taniguchi, M
    Nohira, H
    Hattori, T
    Södergren, S
    Wannberg, B
    Kobayashi, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 547 (01): : 50 - 55
  • [9] Grazing incidence X-ray fluorescence and scattering experiments at BL-39XU, SPring-8
    Sakurai, K
    Eba, H
    Goto, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1999, 38 : 332 - 335
  • [10] BL09XU: an advanced hard X-ray photoelectron spectroscopy beamline of SPring-8
    Yasui, Akira
    Takagi, Yasumasa
    Osaka, Taito
    Senba, Yasunori
    Yamazaki, Hiroshi
    Koyama, Takahisa
    Yumoto, Hirokatsu
    Ohashi, Haruhiko
    Motomura, Koji
    Nakajima, Kyo
    Sugahara, Michihiro
    Kawamura, Naomi
    Tamasaku, Kenji
    Tamenori, Yusuke
    Yabashi, Makina
    JOURNAL OF SYNCHROTRON RADIATION, 2023, 30 (05) : 1013 - 1022