SPring-8 standard x-ray monochromators

被引:86
|
作者
Yabashi, M [1 ]
Yamazaki, H [1 ]
Tamasaku, K [1 ]
Goto, S [1 ]
Takeshita, K [1 ]
Mochizuki, T [1 ]
Yoneda, Y [1 ]
Furukawa, Y [1 ]
Ishikawa, T [1 ]
机构
[1] JASRI, Japan Synchroton Radiat Res Inst, SPring 8, Mikazuki, Hyogo 6795198, Japan
关键词
x-ray monochromator; double-crystal geometry; fixed-exit; rotated-inclined geometry; adjustable-inclined geometry; sagittal focusing; SPring-8;
D O I
10.1117/12.370098
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Most SPring-8 x-ray beamlines are installed double-crystal monochromators that are standardized. For x-ray undulator beamlines where power density of the beam are quite high, rotated-inclined double-crystal geometry is usually adopted, which enlarges the footprint of the incident beam on the crystal surface to reduce the power density. On the other hand, adjustable-inclined double-crystal geometry is adopted for bending-magnet beamlines to extend the available energy range with a limited Bragg angle range. The standardized monochromator mechanism is compatible to both of the geometries, only by changing crystal mounts. Detailed description of the monochromator mechanism is presented.
引用
收藏
页码:2 / 13
页数:12
相关论文
共 50 条
  • [1] Present status of stability improvement of SPring-8 standard x-ray monochromators
    Yamazaki, Hiroshi
    Shimizu, Yasuhiro
    Shimizu, Nobutaka
    Kawamoto, Masahide
    Kawano, Yoshiaki
    Senba, Yasunori
    Ohashi, Haruhiko
    Goto, Shunji
    [J]. ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS III, 2008, 7077
  • [2] Improvement in Stability of SPring-8 Standard X-Ray Monochromators with Water-Cooled Crystals
    Yamazaki, Hiroshi
    Shimizu, Yasuhiro
    Miura, Takanori
    Tanaka, Masayuki
    Kishimoto, Hikaru
    Matsuzaki, Yasuhisa
    Shimizu, Nobtaka
    Kawano, Yoshiaki
    Kumasaka, Takashi
    Yamamoto, Masaki
    Koganezawa, Tomoyuki
    Sato, Masugu
    Hirosawa, Ichiro
    Senba, Yasunori
    Ohashi, Haruhiko
    Goto, Shunji
    Ishikawa, Tetsuya
    [J]. SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 785 - +
  • [3] Standard X-ray mirror systems for SPring-8 beamlines
    Uruga, T
    Tanida, H
    Yoneda, Y
    Takeshita, K
    Goto, S
    Ishikawa, T
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 782 - 784
  • [4] Standard transport channels of X-ray beamlines at SPring-8
    Goto, S
    Yabashi, M
    Ohashi, H
    Kimura, H
    Takeshita, K
    Uruga, T
    Mochizuki, T
    Kohmura, Y
    Kuroda, M
    Yamamoto, M
    Furukawa, Y
    Kamiya, N
    Ishikawa, T
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 1202 - 1205
  • [5] Improvement in stability of SPring-8 X-ray monochromators with cryogenic-cooled silicon crystals
    Yamazaki, Hiroshi
    Ohashi, Haruhiko
    Senba, Yasunori
    Takeuchi, Tomoyuki
    Shimizu, Yasuhiro
    Tanaka, Masayuki
    Matsuzaki, Yasuhisa
    Kishimoto, Hikaru
    Miura, Takanori
    Terada, Yasuko
    Suzuki, Motohiro
    Tajiri, Hiroo
    Goto, Shunji
    Yamamoto, Masaki
    Takata, Masaki
    Ishikawa, Tetsuya
    [J]. 11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [6] X-ray study of forensic samples at the SPring-8
    Ninomiya, Toshio
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2005, 13 (03) : 109 - 116
  • [7] Electronics for SPring-8 X-ray beam monitors
    Kudo, T
    Aoyagi, H
    Shiwaku, H
    Sakurai, Y
    Kitamura, H
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 630 - 631
  • [8] Hard X-ray microscopy activities at SPring-8
    Suzuki, Y
    Awaji, M
    Takeuchi, A
    Takano, H
    Uesugi, K
    Kohmura, Y
    Kamijo, N
    Yasumoto, M
    Tamura, S
    [J]. JOURNAL DE PHYSIQUE IV, 2003, 104 : 35 - 40
  • [9] Soft X-ray photochemistry beamline at SPring-8
    Koyano, I
    Okuyama, M
    Ishiguro, E
    Hiraya, A
    Ohashi, H
    Kanashima, T
    Ueda, K
    Suzuki, IH
    Ibuki, T
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 545 - 547
  • [10] Vacuum system of X-ray beamlines of SPring-8
    Ohashi, H
    Goto, S
    Kishimoto, H
    Murase, T
    Isshiki, M
    Suzuki, Y
    Kimura, H
    Takeshita, K
    Ishikawa, T
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 801 - 804