Cytogenetic analysis of 60Co γ-radiation-induced chromosome damage and simulations using the Geant4 Monte Carlo toolkit

被引:0
|
作者
Fourie, H. [1 ]
Newman, R. T. [1 ]
Slabbert, J. P. [2 ]
Beukes, P. [2 ]
机构
[1] Univ Stellenbosch, Dept Phys, ZA-7602 Stellenbosch, South Africa
[2] Natl Res Fdn, IThemba LABS, ZA-7129 Somerset West, South Africa
关键词
BLOOD-LYMPHOCYTES; MICRONUCLEUS; NEUTRONS; RAYS;
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
The study involves the determination and quantization of radiation damage on a cellular level and the replication of this energy deposition using the Geant4 Monte Carlo toolkit, developed for particle transportation simulations at CERN. The detection of micronuclei in binucleated cells was used to analyse the effects of the radiation. Results from micronucleus assays of rat brain endothelial and Chinese hamster ovary cells that have been irradiated with gamma rays, produced by a Co-60 teletherapy unit at iThemba LABS, are presented. Linear-quadratic dose response curves were determined for both cell lines. The simulated results of the Co-60 setup, irradiation and other relevant features offered by the Geant4 toolkit are also discussed. Finally, prospective microdosimetric studies and simulations of damage caused by DNA-incorporated I-123 will be mentioned.
引用
收藏
页码:248 / 253
页数:6
相关论文
共 50 条
  • [31] Skin dose estimation of Multani Mitti (Fuller's earth) using Geant4 Monte Carlo simulations
    Satti, Khizar Hayat
    Siddique, Muhammad Tariq
    Rehman, Shakeel Ur
    Dilband, Muhammad
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226
  • [32] IMRT treatment Monitor Unit verification using absolute calibrated BEAMnrc and Geant4 Monte Carlo simulations
    Oborn, B. M.
    Williams, M.
    Bailey, M.
    Carolan, M. G.
    XVII INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY (ICCR 2013), 2014, 489
  • [33] Investigation of Perylene as a Converter Material for Fast Neutron Detection and Spectroscopy Using GEANT4 Monte Carlo Simulations
    Tripathi, Shivang
    Upadhyay, Chandrakant
    Nagaraj, C. P.
    Venkatesan, A.
    Devan, K.
    Madhusoodanan, K.
    ADVANCES IN SYSTEMS, CONTROL AND AUTOMATION, 2018, 442 : 189 - 197
  • [34] A Monte Carlo simulation framework to study ASTRO-H in-orbit radiation and detector responses based on Geant4 toolkit
    Ozaki, Masanobu
    Odaka, Hirokazu
    Sato, Tamotsu
    Yasuda, Tetsuya
    Asai, Makoto
    Hiragi, Kazuyoshi
    Mizuno, Tsunefumi
    Mori, Hideyuki
    Terada, Yukikatsu
    Furuzawa, Akihiro
    SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
  • [35] Development of a complete simulation package for Self-Powered Neutron Detectors using the Monte Carlo Method and Geant4 toolkit
    Li, Kun
    Li, Gang
    Wan, Bo
    Yang, Daibo
    Li, Dan
    Weng, Xiaohui
    Li, Ang
    Yin, Qiusheng
    Wang, Haibo
    JOURNAL OF INSTRUMENTATION, 2023, 18 (08)
  • [36] Radioactive gold nanoparticles for cancer treatment: Size and cluster dependent damage studied by Geant4 Monte-Carlo simulations
    Zutta Villate, Julian Mateo
    Hahn, Marc Benjamin
    EUROPEAN PHYSICAL JOURNAL D, 2019, 73 (05):
  • [37] Radiation transport calculations for 50 MV photon therapy beam using the Monte Carlo code Geant4
    Larsson, S
    Svensson, R
    Gudowska, I
    Ivanchenko, V
    Brahme, A
    RADIATION PROTECTION DOSIMETRY, 2005, 115 (1-4) : 503 - 507
  • [38] Geant4 Monte Carlo simulations of the galactic cosmic ray radiation environment on-board the international space station/columbus
    Ersmark, Tore
    Carlson, Per
    Daly, Eamonn
    Fuglesang, Christer
    Gudowska, Irena
    Lund-Jensen, Bengt
    Nieminen, Petteri
    Pearce, Mark
    Santin, Giovanni
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1854 - 1862
  • [39] Monte Carlo modeling of a 60Co MRI-guided radiotherapy system on Geant4 and experimental verification of dose calculation under a magnetic field of 0.35 T
    Okamoto, Hiroyuki
    Nishioka, Shie
    Iijima, Kotaro
    Nakamura, Satoshi
    Sakasai, Tatsuya
    Miura, Yuki
    Takemori, Mihiro
    Nakayama, Hiroki
    Morishita, Yuichiro
    Shimizu, Morihito
    Abe, Yoshihisa
    Igaki, Hiroshi
    Nakayama, Yuko
    Itami, Jun
    JOURNAL OF RADIATION RESEARCH, 2019, 60 (01) : 116 - 123
  • [40] Monte Carlo simulation of NovalisTx linear accelerator using GATE/Geant4 code for dosimetry analysis
    Fathi, Ahmed
    Khobbaizi, Youness
    Nabil, Sanaa
    Ardouz, Anas
    Hasnaoui, Abdellatif
    Sbiaai, Khalid
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 466 - 472