Simulation of scanning capacitance microscopy measurements on ultranarrow doping profiles in silicon

被引:5
|
作者
Giannazzo, F
Goghero, D
Raineri, V
Mirabella, S
Priolo, F
Liotta, SF
Rinaudo, S
机构
[1] INFM, I-95123 Catania, Italy
[2] Univ Catania, Dept Phys & Astron, I-95123 Catania, Italy
[3] CNR, IMM, I-95121 Catania, Italy
[4] STMicroelect, I-95121 Catania, Italy
来源
关键词
D O I
10.1116/1.1622671
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Scanning capacitance microscopy (SCM) has been performed both in cross-sectional and in angle-beveling configurations on ultranarrow B spikes with a full width at the half maximum smaller than the SCM probe diameter. A relevant improvement in the SCM response has been observed passing from the cross section to ten times magnification, but a peculiar asymmetric shape characterizes all the profiles on the beveling configuration and broadening and peak lowering are observed for the narrowest spikes. Accurate two-dimensional simulations allowed us to reproduce the experimentally observed peculiar phenomena. (C) 2004 American Vacuum Society.
引用
收藏
页码:394 / 398
页数:5
相关论文
共 50 条
  • [11] Unintentional doping in GaN assessed by scanning capacitance microscopy
    Sumner, J.
    Das Bakshi, S.
    Oliver, R. A.
    Kappers, M. J.
    Humphreys, C. J.
    [J]. PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2008, 245 (05): : 896 - 898
  • [12] Doping landscapes in the nanometer range by scanning capacitance microscopy
    Anand, S
    Carlström, CF
    Messmer, ER
    Lourdudoss, S
    Landgren, G
    [J]. APPLIED SURFACE SCIENCE, 1999, 144-45 : 525 - 529
  • [13] Scanning capacitance microscopy for thin film measurements
    Lee, DT
    Pelz, JP
    Bhushan, B
    [J]. NANOTECHNOLOGY, 2006, 17 (05) : 1484 - 1491
  • [14] Simulation of Silicon Doping Profiles.
    Kamarinos, G.
    Pananakakis, G.
    Zadworny, F.
    [J]. Onde electrique, 1980, 60 (11): : 33 - 44
  • [15] Scanning capacitance microscopy as a tool for the assessment of unintentional doping in GaN
    Oliver, Rachel A.
    Das Bakshi, Subhankar
    Sumner, Joy
    Kappers, Menno J.
    [J]. PHYSICA STATUS SOLIDI C: CURRENT TOPICS IN SOLID STATE PHYSICS, VOL 6, SUPPL 2, 2009, 6 : S980 - S983
  • [16] Determination of doping type by calibrated capacitance scanning microwave microscopy
    Hommel, S.
    Killat, N.
    Altes, A.
    Schweinboeck, T.
    Kreupl, F.
    [J]. MICROELECTRONICS RELIABILITY, 2017, 76 : 218 - 221
  • [17] EVALUATION OF EMITTER PROFILES AND LATERAL UNIFORMITY ON CRYSTALLINE SILICON PHOTOVOLTAIC CELLS USING SCANNING CAPACITANCE MICROSCOPY
    Kosbar, Laura
    Nxumalo, Jochonia
    Nalaskowski, Jakub
    Hupka, Lukasz
    Molella, Christopher
    Liu, Jun
    Totir, George
    Fisher, Kathryn
    Cotte, John
    Hopstaken, Marinus
    [J]. 35TH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE, 2010,
  • [18] Dopant profiling in silicon nanowires measured by scanning capacitance microscopy
    Bassani, Franck
    Periwal, Priyanka
    Salem, Bassem
    Chevalier, Nicolas
    Mariolle, Denis
    Audoit, Guillaume
    Gentile, Pascal
    Baron, Thierry
    [J]. PHYSICA STATUS SOLIDI-RAPID RESEARCH LETTERS, 2014, 8 (04): : 312 - 316
  • [19] Comparison of scanning capacitance microscopy measurements in open and closed loop modes on highly doped silicon monolayers
    Goghero, D.
    Gautier, B.
    Descamps, A.
    Bremond, G.
    Faucher, M.
    Mariolle, D.
    Bertin, F.
    [J]. SOLID-STATE ELECTRONICS, 2006, 50 (9-10) : 1479 - 1482
  • [20] Evaluation of different oxidation methods for silicon for scanning capacitance microscopy
    Bowallius, O
    Anand, S
    [J]. MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2001, 4 (1-3) : 81 - 84