Variation in Lung Tumour Breathing Motion between Planning Four-dimensional Computed Tomography and Stereotactic Ablative Radiotherapy Delivery and its Dosimetric Implications: Any Role for Four-dimensional Set-up Verification?

被引:10
|
作者
Ruben, J. D. [1 ,2 ]
Seeley, A. [2 ]
Panettieri, V. [2 ]
Ackerly, T. [2 ,3 ]
机构
[1] Monash Univ, Dept Surg, Melbourne, Vic 3004, Australia
[2] Alfred Hosp, William Buckland Radiotherapy Ctr, Prahran, Vic 3184, Australia
[3] RMIT Univ, Dept Phys, Melbourne, Vic, Australia
关键词
Breathing motion; breathing movement; respiratory motion; SABR; stereotactic ablative radiotherapy; BODY RADIATION-THERAPY; GATED RADIOTHERAPY; RESPIRATORY MOTION; CANCER; STRATEGIES; MARGINS; IMPACT; ERRORS; SBRT;
D O I
10.1016/j.clon.2015.08.010
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aims: To investigate variation in tumour breathing motion (TBM) between the planning four-dimensional computed tomograph (4DCT) and treatment itself for primary or secondary lung tumours undergoing stereotactic ablative radiotherapy (SABR). Materials and methods: Sixteen consecutive patients underwent planning 4DCT at least 1 week after implantation of a fiducial marker. The maximal extent of breathing motion of the intra-tumoural fiducial was measured at 4DCT and again at delivery of each SABR fraction on the linac using stereoscopic kilovoltage imaging. Displacements of the fiducial beyond planned limits were measured in three dimensions and represented as vectors. Variation in breathing motion between the planning 4DCT and treatment, and between individual SABR fractions was analysed. Results: Although TBM at treatment exceeded planned tumour motion limits for at least part of the course for all patients, 31% of patients remained consistently within 1 mm, 50% within 2 mm and 69% consistently within 3 mm of planned parameters. However, 19% of patients experienced TBM variation 5 mm or more beyond planned limits for at least one fraction. For all patients, the median displacement vector at treatment beyond the planned motion envelope was 1.0 mm (mean 2.0 mm, range 0-12.7 mm). Variation in TBM at treatment from 4DCT correlated neither with the magnitude of TBM at 4DCT nor with planning target volume size (rs = 0.13, P = 0.62; rs = 0.02, P = 0.94, respectively). Nor was TBM variation related to tumour type or lobar position (P = 0.35, P = 0.06, respectively). Inter-fraction TBM variation was modest, with an average standard deviation of 1.7 mm (0.3-8.7 mm). Conclusions: TBM variation between 4DCT and treatment and between SABR fractions was modest for most patients. However, 19% of patients experienced significant TBM variation that could be clinically relevant for those most severely affected. It seems prudent to carry out on-couch assessment of TBM at each SABR fraction to identify such patients who might benefit from respiratory gating or adaptive radiotherapy to maintain tumour motion within the planned limits. (C) 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:21 / 27
页数:7
相关论文
共 44 条
  • [41] Four-Dimensional Computed Tomography Pulmonary Nodule Elastometry as a Predictor of Regional Recurrence Following Stereotactic Ablative Radiation Therapy for Early-Stage Non-Small Cell Lung Cancer
    Shaffer, J.
    Negahdar, M.
    von Eyben, R.
    Diehn, M.
    Maxim, P. G.
    Loo, B. W., Jr.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E460 - E460
  • [42] Comparison of intensity-modulated radiotherapy planning based on manual and automatically generated contours using deformable image registration in four-dimensional computed tomography of lung cancer patients
    Weiss, Elisabeth
    Wijesooriya, Krishni
    Ramakrishnan, Viswanathan
    Keall, Paul J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (02): : 572 - 581
  • [43] Evaluation of the motion of lung tumors during stereotactic body radiation therapy (SBRT) with four-dimensional computed tomography (4DCT) using real-time tumor-tracking radiotherapy system (RTRT)
    Harada, Keiichi
    Katoh, Norio
    Suzuki, Ryusuke
    Ito, Yoichi M.
    Shimizu, Shinichi
    Onimaru, Rikiya
    Inoue, Tetsuya
    Miyamoto, Naoki
    Shirato, Hiroki
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 305 - 311
  • [44] A comparison of internal target volume definition by limited four-dimensional computed tomography, the addition of patient-specific margins, or the addition of generic margins when planning radical radiotherapy for lymph node-positive non-small cell lung cancer
    Hughes, S.
    McClelland, J.
    Chandler, A.
    Adams, M.
    Boutland, J.
    Withers, D.
    Ahmad, S.
    Blackall, J.
    Tarte, S.
    Hawkes, D.
    Landau, D.
    CLINICAL ONCOLOGY, 2008, 20 (04) : 293 - 300