摘要
Aims: To investigate variation in tumour breathing motion (TBM) between the planning four-dimensional computed tomograph (4DCT) and treatment itself for primary or secondary lung tumours undergoing stereotactic ablative radiotherapy (SABR). Materials and methods: Sixteen consecutive patients underwent planning 4DCT at least 1 week after implantation of a fiducial marker. The maximal extent of breathing motion of the intra-tumoural fiducial was measured at 4DCT and again at delivery of each SABR fraction on the linac using stereoscopic kilovoltage imaging. Displacements of the fiducial beyond planned limits were measured in three dimensions and represented as vectors. Variation in breathing motion between the planning 4DCT and treatment, and between individual SABR fractions was analysed. Results: Although TBM at treatment exceeded planned tumour motion limits for at least part of the course for all patients, 31% of patients remained consistently within 1 mm, 50% within 2 mm and 69% consistently within 3 mm of planned parameters. However, 19% of patients experienced TBM variation 5 mm or more beyond planned limits for at least one fraction. For all patients, the median displacement vector at treatment beyond the planned motion envelope was 1.0 mm (mean 2.0 mm, range 0-12.7 mm). Variation in TBM at treatment from 4DCT correlated neither with the magnitude of TBM at 4DCT nor with planning target volume size (rs = 0.13, P = 0.62; rs = 0.02, P = 0.94, respectively). Nor was TBM variation related to tumour type or lobar position (P = 0.35, P = 0.06, respectively). Inter-fraction TBM variation was modest, with an average standard deviation of 1.7 mm (0.3-8.7 mm). Conclusions: TBM variation between 4DCT and treatment and between SABR fractions was modest for most patients. However, 19% of patients experienced significant TBM variation that could be clinically relevant for those most severely affected. It seems prudent to carry out on-couch assessment of TBM at each SABR fraction to identify such patients who might benefit from respiratory gating or adaptive radiotherapy to maintain tumour motion within the planned limits. (C) 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:21 / 27
页数:7
相关论文
共 44 条
  • [31] Four-dimensional computed tomography scan analysis of tumor and organ motion at varying levels of abdominal compression during stereotactic treatment of lung and liver
    Heinzerling, John H.
    Anderson, John F.
    Papiez, Lech
    Boike, Thomas
    Chien, Stanley
    Zhang, Geoffrey
    Abdulrahman, Ramzi
    Timmerman, Robert
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (05): : 1571 - 1578
  • [32] Effects of respiratory motion on accurate four-dimensional computed tomography acquisition and plan delivery for lung stereotactic body radiation therapy (vol 84, pg 323, 2024)
    Bae, Bong Kyung
    Kim, Sung Joon
    Kim, Jae-Chul
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2024, 84 (07) : 590 - 590
  • [33] Tumor motion changes in stereotactic body radiotherapy for liver tumors: an evaluation based on four-dimensional cone-beam computed tomography and fiducial markers
    Yoshinobu Shimohigashi
    Ryo Toya
    Tetsuo Saito
    Osamu Ikeda
    Masato Maruyama
    Keisuke Yonemura
    Yuji Nakaguchi
    Yudai Kai
    Yasuyuki Yamashita
    Natsuo Oya
    Fujio Araki
    Radiation Oncology, 12
  • [34] Tumor motion changes in stereotactic body radiotherapy for liver tumors: an evaluation based on four-dimensional cone-beam computed tomography and fiducial markers
    Shimohigashi, Yoshinobu
    Toya, Ryo
    Saito, Tetsuo
    Ikeda, Osamu
    Maruyama, Masato
    Yonemura, Keisuke
    Nakaguchi, Yuji
    Kai, Yudai
    Yamashita, Yasuyuki
    Oya, Natsuo
    Araki, Fujio
    RADIATION ONCOLOGY, 2017, 12 : 61
  • [35] Evaluation of Interfractional and Intrafractional Tumor Motion in Stereotactic Liver Radiotherapy, Based On Four-Dimensional Cone-Beam Computed Tomography Using Fiducial Markers
    Shimohigashi, Y.
    Araki, F.
    Toya, R.
    Maruyama, M.
    Nakaguchi, Y.
    MEDICAL PHYSICS, 2016, 43 (06) : 3682 - 3682
  • [36] Effect of abdominal compression on target movement and extension of the external boundary of peripheral lung tumours treated with stereotactic radiotherapy based on four-dimensional computed tomography
    Yuanjun Qi
    Jianbin Li
    Yingjie Zhang
    Qian Shao
    Xijun Liu
    Fengxiang Li
    Jinzhi Wang
    Zhenxiang Li
    Wei Wang
    Radiation Oncology, 16
  • [37] Effect of abdominal compression on target movement and extension of the external boundary of peripheral lung tumours treated with stereotactic radiotherapy based on four-dimensional computed tomography
    Qi, Yuanjun
    Li, Jianbin
    Zhang, Yingjie
    Shao, Qian
    Liu, Xijun
    Li, Fengxiang
    Wang, Jinzhi
    Li, Zhenxiang
    Wang, Wei
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [38] Assessment of gross tumor volume regression and motion changes during radiotherapy for non-small-cell lung cancer as measured by four-dimensional computed tomography
    Britton, Keith R.
    Starkschall, George
    Tucker, Susan L.
    Pan, Tinsu
    Nelson, Christopher
    Chang, Joe Y.
    Cox, James D.
    Mohan, Radhe
    Komaki, Ritsuko
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (04): : 1036 - 1046
  • [39] Time-Adjusted Internal Target Volume (TTV) based on Four-Dimensional Computed Tomography (4D-CT) for Radiotherapy Planning of Lung Cancer
    Nishibuchi, I.
    Kimura, T.
    Nakashima, T.
    Ochi, Y.
    Murakami, Y.
    Kenjo, M.
    Kaneyasu, Y.
    Nagata, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S535 - S535
  • [40] Feasibility of fast, four-dimensional computed tomography-based O-ring LINAC plans for lung stereotactic body radiotherapy in patients with poor performance status
    Heo, Eun Jeong
    Kim, Minseok
    Park, Chun Gun
    Chang, Kyung Hwan
    Kim, Kwang Hyeon
    Shim, Jang Bo
    Park, Young Je
    Kim, Chul Yong
    Lee, Nam Kwon
    Lee, Suk
    FRONTIERS IN ONCOLOGY, 2023, 13