Aims: To investigate variation in tumour breathing motion (TBM) between the planning four-dimensional computed tomograph (4DCT) and treatment itself for primary or secondary lung tumours undergoing stereotactic ablative radiotherapy (SABR). Materials and methods: Sixteen consecutive patients underwent planning 4DCT at least 1 week after implantation of a fiducial marker. The maximal extent of breathing motion of the intra-tumoural fiducial was measured at 4DCT and again at delivery of each SABR fraction on the linac using stereoscopic kilovoltage imaging. Displacements of the fiducial beyond planned limits were measured in three dimensions and represented as vectors. Variation in breathing motion between the planning 4DCT and treatment, and between individual SABR fractions was analysed. Results: Although TBM at treatment exceeded planned tumour motion limits for at least part of the course for all patients, 31% of patients remained consistently within 1 mm, 50% within 2 mm and 69% consistently within 3 mm of planned parameters. However, 19% of patients experienced TBM variation 5 mm or more beyond planned limits for at least one fraction. For all patients, the median displacement vector at treatment beyond the planned motion envelope was 1.0 mm (mean 2.0 mm, range 0-12.7 mm). Variation in TBM at treatment from 4DCT correlated neither with the magnitude of TBM at 4DCT nor with planning target volume size (rs = 0.13, P = 0.62; rs = 0.02, P = 0.94, respectively). Nor was TBM variation related to tumour type or lobar position (P = 0.35, P = 0.06, respectively). Inter-fraction TBM variation was modest, with an average standard deviation of 1.7 mm (0.3-8.7 mm). Conclusions: TBM variation between 4DCT and treatment and between SABR fractions was modest for most patients. However, 19% of patients experienced significant TBM variation that could be clinically relevant for those most severely affected. It seems prudent to carry out on-couch assessment of TBM at each SABR fraction to identify such patients who might benefit from respiratory gating or adaptive radiotherapy to maintain tumour motion within the planned limits. (C) 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:21 / 27
页数:7
相关论文
共 44 条
  • [21] Dosimetric comparison of four-dimensional computed tomography based internal target volume against variations in respiratory motion during treatment between volumetric modulated arc therapy and three-dimensional conformal radiotherapy in lung stereotactic body radiotherapy
    Daimu Fujimoto
    Jun Takatsu
    Naoya Hara
    Masaki Oshima
    Jun Tomihara
    Eisuke Segawa
    Tatsuya Inoue
    Naoto Shikama
    Radiological Physics and Technology, 2024, 17 : 143 - 152
  • [22] Importance of four-dimensional computed tomography simulation in locally advanced lung cancer radiotherapy: impact on reducing planning target volume
    Maric, Slavica
    Janjic, Petar
    Bosancic, Borut
    Mijailovic, Milan
    Lukic, Snezana
    VOJNOSANITETSKI PREGLED, 2022, 79 (12) : 1224 - 1232
  • [23] ASSESSMENT OF NON-SMALL-CELL LUNG CANCER TUMOR MOTION, DOSIMETRIC COVERAGE AND REGRESSION USING FOUR-DIMENSIONAL COMPUTED TOMOGRAPHY
    Houle, A.
    Martel, C.
    Blais, D.
    Despres, P.
    Boudam, K.
    Campeau, M. P.
    Filion, E.
    Vu, T. T. Thuc
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S544 - S545
  • [24] Dosimetric comparison of four-dimensional computed tomography based internal target volume against variations in respiratory motion during treatment between volumetric modulated arc therapy and three-dimensional conformal radiotherapy in lung stereotactic body radiotherapy
    Fujimoto, Daimu
    Takatsu, Jun
    Hara, Naoya
    Oshima, Masaki
    Tomihara, Jun
    Segawa, Eisuke
    Inoue, Tatsuya
    Shikama, Naoto
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (01) : 143 - 152
  • [25] Optimizing Choice of Skin Surrogates for Surface-Guided Stereotactic Body Radiotherapy of Lung Lesions Using Four-Dimensional Computed Tomography
    Leipold, Vanda
    Aleric, Ivana
    Mlinaric, Mihaela
    Kosmina, Domagoj
    Stanic, Fran
    Kasabasic, Mladen
    Stimac, Damir
    Kaucic, Hrvoje
    Ursi, Giovanni
    Schwarz, Karla
    Nikolic, Igor
    Klapan, Denis
    Schwarz, Dragan
    CANCERS, 2024, 16 (13)
  • [26] Four-Dimensional Computed Tomography Prediction of Inter- and Intrafractional Lung Tumor Motion During Fractionated Stereotactic Body Radiation Therapy
    Forsthoefel, M. K.
    Burlile, J.
    Rashid, A.
    Collins, S. P.
    Collins, B. T.
    Lischalk, J. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E747 - E748
  • [27] Dosimetric comparison of free-breathing versus respiratory motion-managed radiotherapy via four-dimensional computed tomography-based volumetric-modulated arctherapy for lung cancer
    Sarihan, S.
    Tunc, S. G.
    Kahraman, A.
    Irem, Z. K.
    CANCER RADIOTHERAPIE, 2023, 27 (08): : 698 - 704
  • [28] Defining Target Volumes for Stereotactic Ablative Radiotherapy of Early-stage Lung Tumours: A Comparison of Three-dimensional 18F-fluorodeoxyglucose Positron Emission Tomography and Four-dimensional Computed Tomography
    Hanna, G. G.
    van Sornsen de Koste, J. R.
    Dahele, M. R.
    Carson, K. J.
    Haasbeek, C. J. A.
    Migchielsen, R.
    Hounsell, A. R.
    Senan, S.
    CLINICAL ONCOLOGY, 2012, 24 (06) : E71 - E80
  • [29] Dosimetric advantages of four-dimensional adaptive image-guided radiotherapy for lung tumors using online cone-beam computed tomography
    Harsolia, Asif
    Hugo, Geoffrey D.
    Kestin, Larry L.
    Grills, Inga S.
    Yan, Di
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (02): : 582 - 589
  • [30] Assessing respiration-induced tumor motion and internal target volume using four-dimensional computed tomography for radiotherapy of lung cancer
    Liu, H. Helen
    Balter, Peter
    Tutt, Teresa
    Choi, Bum
    Zhang, Joy
    Wang, Catherine
    Chi, Melinda
    Luo, Dershan
    Pan, Tinsu
    Hunjan, Sandeep
    Starkschall, George
    Rosen, Isaac
    Prado, Karl
    Liao, Zhongxing
    Chang, Joe
    Komaki, Ritsuko
    Cox, James D.
    Mohan, Radhe
    Dong, Lei
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (02): : 531 - 540