Variation in Lung Tumour Breathing Motion between Planning Four-dimensional Computed Tomography and Stereotactic Ablative Radiotherapy Delivery and its Dosimetric Implications: Any Role for Four-dimensional Set-up Verification?

被引:10
|
作者
Ruben, J. D. [1 ,2 ]
Seeley, A. [2 ]
Panettieri, V. [2 ]
Ackerly, T. [2 ,3 ]
机构
[1] Monash Univ, Dept Surg, Melbourne, Vic 3004, Australia
[2] Alfred Hosp, William Buckland Radiotherapy Ctr, Prahran, Vic 3184, Australia
[3] RMIT Univ, Dept Phys, Melbourne, Vic, Australia
关键词
Breathing motion; breathing movement; respiratory motion; SABR; stereotactic ablative radiotherapy; BODY RADIATION-THERAPY; GATED RADIOTHERAPY; RESPIRATORY MOTION; CANCER; STRATEGIES; MARGINS; IMPACT; ERRORS; SBRT;
D O I
10.1016/j.clon.2015.08.010
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aims: To investigate variation in tumour breathing motion (TBM) between the planning four-dimensional computed tomograph (4DCT) and treatment itself for primary or secondary lung tumours undergoing stereotactic ablative radiotherapy (SABR). Materials and methods: Sixteen consecutive patients underwent planning 4DCT at least 1 week after implantation of a fiducial marker. The maximal extent of breathing motion of the intra-tumoural fiducial was measured at 4DCT and again at delivery of each SABR fraction on the linac using stereoscopic kilovoltage imaging. Displacements of the fiducial beyond planned limits were measured in three dimensions and represented as vectors. Variation in breathing motion between the planning 4DCT and treatment, and between individual SABR fractions was analysed. Results: Although TBM at treatment exceeded planned tumour motion limits for at least part of the course for all patients, 31% of patients remained consistently within 1 mm, 50% within 2 mm and 69% consistently within 3 mm of planned parameters. However, 19% of patients experienced TBM variation 5 mm or more beyond planned limits for at least one fraction. For all patients, the median displacement vector at treatment beyond the planned motion envelope was 1.0 mm (mean 2.0 mm, range 0-12.7 mm). Variation in TBM at treatment from 4DCT correlated neither with the magnitude of TBM at 4DCT nor with planning target volume size (rs = 0.13, P = 0.62; rs = 0.02, P = 0.94, respectively). Nor was TBM variation related to tumour type or lobar position (P = 0.35, P = 0.06, respectively). Inter-fraction TBM variation was modest, with an average standard deviation of 1.7 mm (0.3-8.7 mm). Conclusions: TBM variation between 4DCT and treatment and between SABR fractions was modest for most patients. However, 19% of patients experienced significant TBM variation that could be clinically relevant for those most severely affected. It seems prudent to carry out on-couch assessment of TBM at each SABR fraction to identify such patients who might benefit from respiratory gating or adaptive radiotherapy to maintain tumour motion within the planned limits. (C) 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:21 / 27
页数:7
相关论文
共 44 条
  • [1] Quality assurance of four-dimensional computed tomography for stereotactic ablative radiotherapy
    Nailon, W. H.
    Vaque, J. Puxeu
    McLaren, D. B.
    Erridge, S. C.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S261 - S261
  • [2] EFFECTIVE DOSES IN FOUR-DIMENSIONAL COMPUTED TOMOGRAPHY FOR LUNG RADIOTHERAPY PLANNING
    Mori, Shinichiro
    Ko, Susumu
    Ishii, Takayosfii
    Nishizawa, Kanae
    MEDICAL DOSIMETRY, 2009, 34 (01) : 87 - 90
  • [3] An analysis of respiratory induced kidney motion on four-dimensional computed tomography and its implications for stereotactic kidney radiotherapy
    Shankar Siva
    Daniel Pham
    Suki Gill
    Mathias Bressel
    Kim Dang
    Thomas Devereux
    Tomas Kron
    Farshad Foroudi
    Radiation Oncology, 8
  • [4] An analysis of respiratory induced kidney motion on four-dimensional computed tomography and its implications for stereotactic kidney radiotherapy
    Siva, Shankar
    Pham, Daniel
    Gill, Suki
    Bressel, Mathias
    Dang, Kim
    Devereux, Thomas
    Kron, Tomas
    Foroudi, Farshad
    RADIATION ONCOLOGY, 2013, 8
  • [5] Both four-dimensional computed tomography and four-dimensional cone beam computed tomography under-predict lung target motion during radiotherapy
    Steiner, Elisabeth
    Shieh, Chun-Chien
    Caillet, Vincent
    Booth, Jeremy
    O'Brien, Ricky
    Briggs, Adam
    Hardcastle, Nicholas
    Jayamanne, Dasantha
    Szymura, Kathryn
    Eade, Thomas
    Keall, Paul
    RADIOTHERAPY AND ONCOLOGY, 2019, 135 : 65 - 73
  • [6] Quantification of motion of different thoracic locations using four-dimensional computed tomography: Implications for radiotherapy planning
    Maxim, Peter G.
    Loo, Billy W., Jr.
    Shirazi, Haider
    Thorndyke, Brian
    Luxton, Gary
    Le, Quynh-Thu
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (05): : 1395 - 1401
  • [7] Predictors of Respiratory-induced Lung Tumour Motion Measured on Four-dimensional Computed Tomography
    Tan, K. V.
    Thomas, R.
    Hardcastle, N.
    Pham, D.
    Kron, T.
    Foroudi, F.
    Ball, D.
    te Marvelde, L.
    Bressel, M.
    Siva, S.
    CLINICAL ONCOLOGY, 2015, 27 (04) : 197 - 204
  • [8] Four-dimensional planning for motion synchronized dose delivery in lung stereotactic body radiation therapy
    Tachibana, Hidenobu
    Sawant, Amit
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 (03) : 467 - 472
  • [9] Four-dimensional multislice computed tomography for determination of respiratory lung tumor motion in conformal radiotherapy
    Leter, EM
    Cademartiri, F
    Levendag, PC
    Flohr, T
    Stam, H
    Nowak, PJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (03): : 888 - 892
  • [10] Effects of respiratory motion on accurate four-dimensional computed tomography acquisition and plan delivery for lung stereotactic body radiation therapy
    Bae, Bong Kyung
    Kim, Sung Joon
    Kim, Jae-Chul
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2024, 84 (04) : 323 - 334