Rapid Detection of Mycoplasma pneumoniae by Loop-Mediated Isothermal Amplification (LAMP) in Clinical Respiratory Specimens

被引:1
|
作者
Arfaatabar, Maryam [1 ]
Noori Goodarzi, Narjes [1 ]
Afshar, Davoud [2 ]
Memariani, Hamed [3 ]
Azimi, Ghasem [4 ]
Masoorian, Ensieh [1 ]
Pourmand, Mohammad Reza [1 ,5 ]
机构
[1] Univ Tehran Med Sci, Sch Publ Hlth, Dept Pathobiol, Tehran, Iran
[2] Zanjan Univ Med Sci, Sch Med, Dept Microbiol & Virol, Zanjan, Iran
[3] Pasteur Inst Iran, Biotechnol Res Ctr, Tehran, Iran
[4] Shahed Univ Med Sci, Dept Internal Med, Tehran, Iran
[5] Univ Tehran Med Sci, Biotechnol Res Ctr, Tehran, Iran
关键词
Mycoplasma pneumoniae; PCR; Loop-mediated isothermal amplification (LAMP); Culture; DIAGNOSIS; ASSAY; CHILDREN; DNA;
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Mycoplasma pneumoniae is a common cause of community-acquired pneumonia (CAP) worldwide, especially among children and debilitated populations. The present study aimed to investigate a loop-mediated isothermal amplification (LAMP) technique for rapid detection of M. pneumoniae in clinical specimens collected from patients with pneumonia. Methods: Throat swabs were collected from 110 outpatients who suffered from pneumonia. Throat swab samples were obtained from patients referred to the hospital outpatient clinics of Tehran University hospitals, Iran in 2017. The presence of M. pneumoniae in the clinical specimens was evaluated by LAMP, PCR and culture methods. Sensitivity and specificity of the LAMP and PCR assays were also determined. Results: Out of 110 specimens, LAMP assay detected M. pneumoniae in 35 specimens. Detection limit of the LAMP assay was determined to be 33fg /mu L or similar to 40 genome copies/reaction. Moreover, no cross-reaction with genomic DNA from other bacteria was observed. Only 25 specimens were positive by the culture method. The congruence between LAMP assay and culture method was 'substantial' (x=0.77). Specificity and sensitivity of LAMP assay were 88.2%, 100% in compare with culture. However, the congruence between LAMP assay and PCR assay was 'almost perfect' (x=0.86). Specificity and sensitivity of LAMP assay were 92.5%, 100% in compare with PCR. Conclusion: Overall, the LAMP assay is a rapid and cost-efficient laboratory test in comparison to other methods including PCR and culture. Therefore, the LAMP method can be applied in identification of M. pneumoniae isolates in respiratory specimens.
引用
收藏
页码:917 / 924
页数:8
相关论文
共 50 条
  • [21] Establishment of Multiplex Loop-Mediated Isothermal Amplification for Rapid Detection of Genitourinary Mycoplasma
    Wang, Yichao
    Cheng, You
    Xie, Jiaogui
    Liu, Yunde
    CLINICAL LABORATORY, 2018, 64 (7-8) : 1217 - 1224
  • [22] Detection of Mycoplasma pneumoniae by loop-mediated isothermal amplification (LAMP) assay and serology in pediatric community-acquired pneumonia
    Gotoh, Kensei
    Nishimura, Naoko
    Ohshima, Yasunori
    Arakawa, Yasuko
    Hosono, Haruki
    Yamamoto, Yasuto
    Iwata, Yasushi
    Nakane, Kazumasa
    Funahashi, Keiji
    Ozaki, Takao
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2012, 18 (05) : 662 - 667
  • [23] Development of a Loop-Mediated Isothermal Amplification Assay for Rapid Detection of Mycoplasma hyorhinis
    Du, Gai-Mei
    Liu, Mao-Jun
    Wu, Yu-Zi
    Xiong, Qi-Yan
    Bai, Fang-Fang
    Feng, Zhi-Xin
    Shao, Guo-Qing
    CLINICAL LABORATORY, 2013, 59 (11-12) : 1363 - 1371
  • [24] Use of loop-mediated isothermal amplification of DNA for the rapid detection of Mycobacterium tuberculosis in clinical specimens
    Neonakis, I. K.
    Spandidos, D. A.
    Petinaki, E.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2011, 30 (08) : 937 - 942
  • [25] Use of loop-mediated isothermal amplification of DNA for the rapid detection of Mycobacterium tuberculosis in clinical specimens
    I. K. Neonakis
    D. A. Spandidos
    E. Petinaki
    European Journal of Clinical Microbiology & Infectious Diseases, 2011, 30 : 937 - 942
  • [26] Combination of procedure for ultra rapid extraction (PURE) and loop-mediated isothermal amplification (LAMP) for rapid detection of Mycoplasma bovis in milk
    Itoh, Megumi
    Hirano, Yuki
    Yamakawa, Kazuhiro
    Yasutomi, Ichiro
    Kuramoto, Keiko
    Furuoka, Miyuki
    Yamada, Kazutaka
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2020, 82 (07): : 875 - 880
  • [27] Detection of Mycoplasma wenyonii in cattle and transmission vectors by the loop-mediated isothermal amplification (LAMP) assay
    Song, Qiqi
    Wang, Lixia
    Fang, Rui
    Khan, Muhammad Kasib
    Zhou, Yanqin
    Zhao, Junlong
    TROPICAL ANIMAL HEALTH AND PRODUCTION, 2012, 45 (01) : 247 - 250
  • [28] Detection of Mycoplasma wenyonii in cattle and transmission vectors by the loop-mediated isothermal amplification (LAMP) assay
    Qiqi Song
    Lixia Wang
    Rui Fang
    Muhammad Kasib Khan
    Yanqin Zhou
    Junlong Zhao
    Tropical Animal Health and Production, 2012, 45 : 247 - 250
  • [29] Loop-Mediated Isothermal Amplification (LAMP) for the Detection of Salmonella in Food
    P. A. Kokkinos
    P. G. Ziros
    M. Bellou
    A. Vantarakis
    Food Analytical Methods, 2014, 7 : 512 - 526
  • [30] Detection of phytoplasma by loop-mediated isothermal amplification of DNA (LAMP)
    Obura, E.
    Masiga, D.
    Wachira, F.
    Gurja, B.
    Khan, Z. R.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2011, 84 (02) : 312 - 316