Rapid Detection of Mycoplasma pneumoniae by Loop-Mediated Isothermal Amplification (LAMP) in Clinical Respiratory Specimens

被引:1
|
作者
Arfaatabar, Maryam [1 ]
Noori Goodarzi, Narjes [1 ]
Afshar, Davoud [2 ]
Memariani, Hamed [3 ]
Azimi, Ghasem [4 ]
Masoorian, Ensieh [1 ]
Pourmand, Mohammad Reza [1 ,5 ]
机构
[1] Univ Tehran Med Sci, Sch Publ Hlth, Dept Pathobiol, Tehran, Iran
[2] Zanjan Univ Med Sci, Sch Med, Dept Microbiol & Virol, Zanjan, Iran
[3] Pasteur Inst Iran, Biotechnol Res Ctr, Tehran, Iran
[4] Shahed Univ Med Sci, Dept Internal Med, Tehran, Iran
[5] Univ Tehran Med Sci, Biotechnol Res Ctr, Tehran, Iran
关键词
Mycoplasma pneumoniae; PCR; Loop-mediated isothermal amplification (LAMP); Culture; DIAGNOSIS; ASSAY; CHILDREN; DNA;
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Mycoplasma pneumoniae is a common cause of community-acquired pneumonia (CAP) worldwide, especially among children and debilitated populations. The present study aimed to investigate a loop-mediated isothermal amplification (LAMP) technique for rapid detection of M. pneumoniae in clinical specimens collected from patients with pneumonia. Methods: Throat swabs were collected from 110 outpatients who suffered from pneumonia. Throat swab samples were obtained from patients referred to the hospital outpatient clinics of Tehran University hospitals, Iran in 2017. The presence of M. pneumoniae in the clinical specimens was evaluated by LAMP, PCR and culture methods. Sensitivity and specificity of the LAMP and PCR assays were also determined. Results: Out of 110 specimens, LAMP assay detected M. pneumoniae in 35 specimens. Detection limit of the LAMP assay was determined to be 33fg /mu L or similar to 40 genome copies/reaction. Moreover, no cross-reaction with genomic DNA from other bacteria was observed. Only 25 specimens were positive by the culture method. The congruence between LAMP assay and culture method was 'substantial' (x=0.77). Specificity and sensitivity of LAMP assay were 88.2%, 100% in compare with culture. However, the congruence between LAMP assay and PCR assay was 'almost perfect' (x=0.86). Specificity and sensitivity of LAMP assay were 92.5%, 100% in compare with PCR. Conclusion: Overall, the LAMP assay is a rapid and cost-efficient laboratory test in comparison to other methods including PCR and culture. Therefore, the LAMP method can be applied in identification of M. pneumoniae isolates in respiratory specimens.
引用
收藏
页码:917 / 924
页数:8
相关论文
共 50 条
  • [41] Sensitive and rapid detection of Schistosoma japonicum DNA by loop-mediated isothermal amplification (LAMP)
    Xu, J.
    Rong, R.
    Zhang, H. Q.
    Shi, C. J.
    Zhu, X. Q.
    Xia, C. M.
    INTERNATIONAL JOURNAL FOR PARASITOLOGY, 2010, 40 (03) : 327 - 331
  • [42] Rapid Detection of Clostridium botulinum in Food Using Loop-Mediated Isothermal Amplification (LAMP)
    Chen, Yufei
    Li, Hao
    Yang, Liu
    Wang, Lei
    Sun, Ruyi
    Shearer, Julia E. S.
    Sun, Fengjie
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (09)
  • [43] Development of Loop-Mediated Isothermal Amplification (LAMP) Assay for the Rapid Detection of Alternaria alternata
    Zhang, Xinyue
    Xu, Guojie
    Tang, Huaqi
    Li, Yanpeng
    Liu, Chunsheng
    JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (01) : 99 - 103
  • [44] Development of Loop-Mediated Isothermal Amplification (LAMP) Assays for Rapid Detection of Ehrlichia ruminantium
    Nakao, Ryo
    Stromdahl, Ellen Y.
    Magona, Joseph W.
    Faburay, Bonto
    Namangala, Boniface
    Malele, Imna
    Inoue, Noboru
    Geysen, Dirk
    Kajino, Kiichi
    Jongejan, Frans
    Sugimoto, Chihiro
    BMC MICROBIOLOGY, 2010, 10
  • [45] Rapid detection of Mycoplasma bovis by real-time Loop-mediated isothermal amplification
    Pan, Yan
    Wei, Ying Ming
    Garmendia, A. E.
    Peng, Hao
    Feng, Shi Wen
    Tao, Li
    Li, Jun
    THAI JOURNAL OF VETERINARY MEDICINE, 2020, 50 (03): : 363 - 369
  • [46] Development of a loop-mediated isothermal amplification assay for sensitive and rapid detection of Mycoplasma bovis
    Bai, ZhiDi
    Shi, Lei
    Hu, Changmin
    Chen, Xi
    Qi, Jingjing
    Ba, Xiaoliang
    Peng, Qingjie
    Chen, Yingyu
    Chen, Huanchun
    Guo, Aizhen
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (57): : 12333 - 12338
  • [47] Loop-mediated isothermal amplification for the rapid detection of Salmonella
    Hara-Kudo, Y
    Yoshino, M
    Kojima, T
    Ikedo, M
    FEMS MICROBIOLOGY LETTERS, 2005, 253 (01) : 155 - 161
  • [48] Detection of Streptococcus pneumoniae in Urine by Loop-Mediated Isothermal Amplification
    Cima-Cabal, Maria Dolores
    Vazquez-Espinosa, Emma
    Vazquez, Fernando
    Garcia-Suarez, Maria del Mar
    JOURNAL OF PEDIATRIC INFECTIOUS DISEASES, 2021, 16 (01) : 18 - 25
  • [49] Development and evaluation of a loop-mediated isothermal amplification method for the rapid detection of Chlamydophila pneumoniae
    Kawai, Y.
    Miyashita, N.
    Kishi, F.
    Tabuchi, M.
    Oda, K.
    Yamaguchi, T.
    Kawasaki, K.
    Yamazaki, T.
    Ouchi, K.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2009, 28 (07) : 801 - 805
  • [50] Loop-mediated isothermal amplification (LAMP) in the respiratory specimens for the diagnosis of pediatric pulmonary tuberculosis: A pilot study
    K.S., Sreedeep
    Sethi, Sunil
    Yadav, Rakesh
    Vaidya, Pankaj C.
    Angurana, Suresh Kumar
    Saini, Aastha
    Mehra, Nancy
    Singh, Meenu
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2020, 26 (08) : 823 - 830