COMPARISON OF GLUCOSE POINT-OF-CARE VALUES WITH LABORATORY VALUES IN CRITICALLY ILL PATIENTS

被引:25
|
作者
Shearer, Anna [1 ]
Boehmer, Marilyn [1 ]
Closs, Melanie [1 ]
Dela Rosa, Rosalina [1 ]
Hamilton, Jean [1 ]
Horton, Karen [1 ]
McGrath, Rose [1 ]
Schulman, Christine
机构
[1] Providence St Vincents Med Ctr, Intens Care Unit, Portland, OR 97225 USA
关键词
INTENSIVE INSULIN THERAPY; ARTERIAL-BLOOD; METERS; HEMATOCRIT; CAPILLARY; ACCURACY; REFLECTANCE; AGREEMENT; MONITORS; PH;
D O I
10.4037/ajcc2009448
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Blood from central venous or arterial catheters as well as from fingersticks is often used for point-of-care glucose testing. Objectives To compare glucose values obtained with a point-of-care device for catheter and fingerstick blood samples with values obtained by clinical laboratory analysis of a catheter blood sample. Methods A method-comparison design was used. Point-of-care values for fingerstick and catheter blood samples were compared with laboratory values for blood from catheters in a convenience sample of 63 critically ill patients. Device bias and precision were calculated and graphed according to the Bland-Altman method, and a t test was used to determine differences in glucose values for the 2 methods. Results Laboratory glucose values for blood from a catheter sample differed significantly from point-of-care values for blood from a fingerstick (t(1,61) = 5.01; P < .001) and from a catheter (t(1,61) = 3.91; P < .001). Bias and precision for the point-of-care device was large (fingerstick, 8.7 and 13.7; catheter, 7.0 and 14.0); 20% of the values differed from the laboratory glucose values by more than 20 mg/dL. Point-of-care glucose values for fingerstick and catheter samples did not differ (P = .41). Conclusions Glucose values obtained with a point-of-care device differ significantly from those obtained by laboratory analysis. The magnitude of these differences calls into question the widespread practice of using point-of-care glucose testing to guide insulin titration for tight glucose control. Errors in dosing could easily be made because of the large bias and precision associated with a point-of-care device. (American Journal of Critical Care. 2009; 18: 224-230)
引用
收藏
页码:224 / 230
页数:7
相关论文
共 50 条
  • [21] Glucose determination from different vascular compartments by point-of-care testing in critically ill patients
    Chakravarthy, SB
    Markewitz, BA
    Lehman, C
    Orme, JF
    CHEST, 2005, 128 (04) : 220S - 221S
  • [22] Point-of-care glucose testing in critically ill patients: Visual logistics and a glycemic variability hypothesis
    Kost, Gerald J.
    Tran, Nam K.
    Sifontes, Jorge R.
    Mecozzi, Dan M.
    Louie, Richard F.
    Abad, Victor J.
    CRITICAL CARE MEDICINE, 2009, 37 (10) : 2841 - 2843
  • [23] Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients
    Anouk M Corstjens
    Jack JM Ligtenberg
    Iwan CC van der Horst
    Rob Spanjersberg
    Joline SW Lind
    Jaap E Tulleken
    John HJM Meertens
    Jan G Zijlstra
    Critical Care, 10
  • [24] Point-of-care creatinine vs. central laboratory creatinine in the critically ill
    White, Kyle C.
    McCullough, James
    Shekar, Kiran
    Senthuran, Siva
    Laupland, Kevin B.
    Dimeski, Goce
    Serpa-Neto, Ary
    Bellomo, Rinaldo
    CRITICAL CARE AND RESUSCITATION, 2024, 26 (03) : 198 - 203
  • [25] Point-of-Care Versus Central Laboratory Measurements of Hemoglobin, Hematocrit, Glucose, Bicarbonate and Electrolytes: A Prospective Observational Study in Critically Ill Patients
    Allardet-Servent, Jerome
    Lebsir, Melissa
    Dubroca, Christian
    Fabrigoule, Martine
    Jordana, Sylvie
    Signouret, Thomas
    Castanier, Matthias
    Thomas, Guillemette
    Soundaravelou, Rettinavelou
    Lepidi, Anne
    Delapierre, Laurence
    Penaranda, Guillaume
    Halfon, Philippe
    Seghboyan, Jean-Marie
    PLOS ONE, 2017, 12 (01):
  • [26] Inaccuracy of Venous Point-of-Care Glucose Measurements in Critically Ill Patients: A Cross-Sectional Study
    Pereira, Adriano Jose
    Correa, Thiago Domingos
    de Almeida, Francisca Pereira
    Deliberato, Rodrigo Octavio
    Lobato, Michelle dos Santos
    Akamine, Nelson
    Silva, Eliezer
    Cavalcanti, Alexandre Biasi
    PLOS ONE, 2015, 10 (06):
  • [27] A critical appraisal of point-of-care coagulation testing in critically ill patients
    Levi, M.
    Hunt, B. J.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2015, 13 (11) : 1960 - 1967
  • [28] Point-of-care assessment of microvascular blood flow in critically ill patients
    Ryan C. Arnold
    Joseph E. Parrillo
    R. Phillip Dellinger
    Michael E. Chansky
    Nathan I. Shapiro
    David J. Lundy
    Stephen Trzeciak
    Steven M. Hollenberg
    Intensive Care Medicine, 2009, 35 : 1761 - 1766
  • [29] Point-of-care assessment of microvascular blood flow in critically ill patients
    Arnold, Ryan C.
    Parrillo, Joseph E.
    Dellinger, R. Phillip
    Chansky, Michael E.
    Shapiro, Nathan I.
    Lundy, David J.
    Trzeciak, Stephen
    Hollenberg, Steven M.
    INTENSIVE CARE MEDICINE, 2009, 35 (10) : 1761 - 1766
  • [30] Point-of-care glucose measurement systems should be used with great caution in critically ill intensive care unit patients
    Hoedemaekers, Cornelia W.
    Gunnewiek, Jacqueline M. T. Klein
    Van der Hoeven, Johannes G.
    CRITICAL CARE MEDICINE, 2010, 38 (01) : 339 - 339