COMPARISON OF GLUCOSE POINT-OF-CARE VALUES WITH LABORATORY VALUES IN CRITICALLY ILL PATIENTS

被引:25
|
作者
Shearer, Anna [1 ]
Boehmer, Marilyn [1 ]
Closs, Melanie [1 ]
Dela Rosa, Rosalina [1 ]
Hamilton, Jean [1 ]
Horton, Karen [1 ]
McGrath, Rose [1 ]
Schulman, Christine
机构
[1] Providence St Vincents Med Ctr, Intens Care Unit, Portland, OR 97225 USA
关键词
INTENSIVE INSULIN THERAPY; ARTERIAL-BLOOD; METERS; HEMATOCRIT; CAPILLARY; ACCURACY; REFLECTANCE; AGREEMENT; MONITORS; PH;
D O I
10.4037/ajcc2009448
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Blood from central venous or arterial catheters as well as from fingersticks is often used for point-of-care glucose testing. Objectives To compare glucose values obtained with a point-of-care device for catheter and fingerstick blood samples with values obtained by clinical laboratory analysis of a catheter blood sample. Methods A method-comparison design was used. Point-of-care values for fingerstick and catheter blood samples were compared with laboratory values for blood from catheters in a convenience sample of 63 critically ill patients. Device bias and precision were calculated and graphed according to the Bland-Altman method, and a t test was used to determine differences in glucose values for the 2 methods. Results Laboratory glucose values for blood from a catheter sample differed significantly from point-of-care values for blood from a fingerstick (t(1,61) = 5.01; P < .001) and from a catheter (t(1,61) = 3.91; P < .001). Bias and precision for the point-of-care device was large (fingerstick, 8.7 and 13.7; catheter, 7.0 and 14.0); 20% of the values differed from the laboratory glucose values by more than 20 mg/dL. Point-of-care glucose values for fingerstick and catheter samples did not differ (P = .41). Conclusions Glucose values obtained with a point-of-care device differ significantly from those obtained by laboratory analysis. The magnitude of these differences calls into question the widespread practice of using point-of-care glucose testing to guide insulin titration for tight glucose control. Errors in dosing could easily be made because of the large bias and precision associated with a point-of-care device. (American Journal of Critical Care. 2009; 18: 224-230)
引用
收藏
页码:224 / 230
页数:7
相关论文
共 50 条
  • [41] The utility of point-of-care ultrasound in the assessment of volume status in acute and critically ill patients
    Pourmand, Ali
    Pyle, Matthew
    Yamane, David
    Sumon, Kazi
    Frasure, Sarah E.
    WORLD JOURNAL OF EMERGENCY MEDICINE, 2019, 10 (04) : 232 - 238
  • [42] The utility of point-of-care ultrasound in the assessment of volume status in acute and critically ill patients
    Ali Pourmand
    Matthew Pyle
    David Yamane
    Kazi Sumon
    Sarah E.Frasure
    World Journal of Emergency Medicine, 2019, (04) : 232 - 238
  • [43] The utility of point-of-care ultrasound in the assessment of volume status in acute and critically ill patients
    Ali Pourmand
    Matthew Pyle
    David Yamane
    Kazi Sumon
    Sarah E.Frasure
    World Journal of Emergency Medicine, 2019, 10 (04) : 232 - 238
  • [44] Evaluation of point-of-care testing in critically unwell patients: comparison with clinical laboratory analysers and applicability to patients with Ebolavirus infection
    Kok, Jen
    Ng, Jimmy
    Li, Stephen C.
    Giannoutsos, John
    Nayyar, Vineet
    Iredell, Jonathan R.
    Dwyer, Dominic E.
    Chen, Sharon C-A.
    PATHOLOGY, 2015, 47 (05) : 405 - 409
  • [45] Electrolytes assessed by point-of-care testing - Are the values comparable with results obtained from the central laboratory?
    Chacko, Binila
    Peter, John Victor
    Patole, Shalom
    Fleming, Jude Joseph
    Selvakumar, Ratnasamy
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2011, 15 (01) : 24 - 29
  • [46] Correction factor to improve agreement between point-of-care and laboratory International Normalized Ratio values
    Johnson, Stacy A.
    Vazquez, Sara R.
    Fleming, Ryan
    Lanspa, Michael J.
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2017, 74 (01) : E24 - E31
  • [47] Comparison of two methods for converting central venous values of acid-base status to arterial values in critically ill patients
    Shastri, Lisha
    Boulain, Thierry
    Rees, Stephen Edward
    Thomsen, Lars Pilegaard
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 203
  • [48] Comparison of two point-of-care measurements of hemoglobin against standard laboratory values during pediatric liver transplantation: A retrospective review
    Morris, Bethany L.
    Hajduk, John
    Cheon, Eric C.
    Ballard, Heather A.
    Burjek, Nicholas E.
    PEDIATRIC ANESTHESIA, 2022, 32 (10) : 1121 - 1128
  • [49] Accuracy of Point-of-Care Blood Glucometers in Neonates and Critically Ill Adults
    Sheen, Yi-Jing
    Wang, Jiunn-Min
    Tsai, Pi-fen
    Lee, Wen-Jane
    Hsu, Ya-Chi
    Wang, Chen-Yu
    Sheu, Wayne H. -H.
    CLINICAL THERAPEUTICS, 2023, 45 (07) : 643 - 648
  • [50] A COMPARISON OF CENTRAL VENOUS AND ARTERIAL BLOOD GAS VALUES IN CRITICALLY ILL
    PHILLIPS, B
    PERETZ, DI
    ANNALS OF INTERNAL MEDICINE, 1969, 70 (04) : 745 - +