Evaluation of enamel loss by scanning electron microscopy after debonding brackets place with four different adhesives

被引:3
|
作者
Rodriguez-Chavez, Jacqueline Adelina [1 ]
Arenas-Alatorre, Jesus Angel [2 ]
Flores-Ruiz, Hugo M. [3 ]
Flores-Ledesma, Abigailt [4 ]
Aguilar-Perez, Fernando Javier [5 ]
机构
[1] Univ Guadalajara, Dept Clin Odontol Integrales, Ctr Univ Ciencias Salud, Salvador Quevedo & Zubieta 228,Edificio B, Guadalajara 44340, Jalisco, Mexico
[2] Univ Nacl Autonoma Mexico, Dept Mat Condensada, Inst Fis, Circuito Invest Cient S-N,Ciudad Univ, Mexico City 04510, DF, Mexico
[3] Univ Guadalajara, Dept Ciencias Nat & Exactas, CUValles Campus, Ameca 46600, Jalisco, Mexico
[4] Benemerita Univ Autonoma Puebla, Fac Estomatol, 31 Poniente 1304, Puebla 72410, Mexico
[5] Univ Autonoma Yucatan, Fac Odontol, Campus Ciencias Salud,Calle 61-A 492-A, Merida 97000, Yucatan, Mexico
关键词
adhesion; scanning electron microscope; shear bonding strength; tooth enamel loss; SHEAR BOND STRENGTH; SELF-ETCHING PRIMER; ORTHODONTIC BRACKETS; CERAMIC BRACKETS; REMOVAL; COMPOSITE;
D O I
10.1002/jemt.23652
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
The clinically adequate shear bond strengths (SBS) should be from 2.8 to 10 MPa. The aim of this research is to observe tooth enamel loss through a scanning electron microscope (SEM) during the debonding of braces of four adhesive systems. Then, 100 premolars were used in 4 groups of 25 specimens each, for Transbond MIP (G1), Enlight (G2), Stylus (G3), and Transbond Plus SEP (G4). The research was done under the NOM ISO/TS 11405:2015. Gemini 3M were placed under the manufacturer's recommendations. The SBS test was done at 24 hr in an Instron electromechanical universal testing machine at 1 mm/1 min. Adhesive remnant index (ARI) was measured, all of the brackets where examined in the SEM. For the shear bonding strength G1 = 10.09 +/- 2.73 MPa, G2 = 9.27 +/- 3.99 MPa, G3 = 7.83 +/- 4.46 MPa, and G4 = 6.40 +/- 2.85 MPa statistically significant differences were found when comparing the four groups (p = .002). In the Tukey post hoc test, G1 versus G4 and G2 versus G4, statistically significant differences were found. For the ARI a value of 1 in 46%, followed by a value of 2 in 38%, a value of 3 in 13% and a value of 0 in 3% of the total samples, finding statistically significant differences (p < .001). In relation to the tooth enamel loss due to SBS, statistically significant differences were found (p = .326). G1 and G4 had not statistically significant differences. Even though our results concur with the appropriate clinical values, we observed tooth enamel loss with Transbond Plus SEP and Stylus.
引用
收藏
页码:912 / 920
页数:9
相关论文
共 50 条
  • [41] pH Effects of Soda, Brew, and Citrus on Adhesive Bond Strength of Orthodontic Brackets to the Enamel. Scanning Electron Microscopy and Adhesive Remnant Index Analysis
    Sultan, Hareem
    Kamran, Muhammad Abdullah
    Almoammar, Salem
    Al Jearah, Mohammed Mohsen
    Khan, Mariam
    Mahmood, Syed Junaid
    Ahmed, Ghulam
    Mahmood, Mirza
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2023, 13 (04) : 588 - 593
  • [42] Scanning electron microscopy evaluation of the interfacial fit of interchanged components of four dental implant systems
    Dellow, AG
    Driessen, CH
    Nel, HJC
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 1997, 10 (03) : 216 - 221
  • [43] COMPOSITE AND INTERMEDIATE RESIN TAG FORMATION IN ACID-ETCHED ENAMEL - A SCANNING ELECTRON-MICROSCOPY EVALUATION
    PREVOST, AP
    FULLER, JL
    PETERSON, LC
    JOURNAL OF PROSTHETIC DENTISTRY, 1984, 52 (02): : 204 - 207
  • [44] Scanning Electron Microscopy Analysis of Marginal Adaptation of Composite Resines to Enamel after Using of Standard and Gradual Photopolimerization
    Dacic, Stefan
    Dacic-Simonovic, Dragica
    Zivkovic, Slavoljub
    Dacic, Milos
    Radicevic, Goran
    Mitic, Aleksandar
    Tosic, Goran
    Igic, Marko
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2014, 142 (7-8) : 404 - 412
  • [45] Blood clot stabilization after different mechanical and chemical root treatments: a morphological evaluation using scanning electron microscopy
    Stefanini, Martina
    Ceraolo, Edoardo
    Mazzitelli, Claudia
    Maravic, Tatjana
    Sangiorgi, Matteo
    Zucchelli, Giovanni
    Breschi, Lorenzo
    Mazzoni, Annalisa
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2022, 52 (01): : 54 - 64
  • [46] Morphological confocal laser scanning microscope evaluation of four different "etch and rinse" adhesives in post endodontic restoration
    Marigo, Luca
    Lajolo, Carlo
    Castagnola, Raffaella
    Angerame, Daniele
    Somma, Francesco
    DENTAL MATERIALS JOURNAL, 2012, 31 (06) : 988 - 994
  • [47] Scanning electron Microscopy reveals different response pattern of four Vitis genotypes to Xylella fastidiosa infection
    Fritschi, Felix B.
    Lin, Hong
    Walker, M. Andrew
    PLANT DISEASE, 2008, 92 (02) : 276 - 286
  • [48] Comparative evaluation of enamel surface roughness after debonding using four finishing and polishing systems for residual resin removal—an in vitro study
    Priyanka Shah
    Padmaja Sharma
    Santosh Kumar Goje
    Nikita Kanzariya
    Maitry Parikh
    Progress in Orthodontics, 20
  • [49] New approach in the evaluation of hydrosalpinx: Scanning electron microscopy after NaOH maceration.
    Vizza, E
    Correr, S
    Heyn, R
    Vittori, V
    Sbiroli, C
    Motta, PM
    NEW TECHNOLOGIES IN REPRODUCTIVE MEDICINE, NEONATOLOGY AND GYNECOLOGY, 1999, : 303 - 306
  • [50] Evaluation of sutures after immersion in nonalcoholic benzydamine hydrochloride mouthrinse by scanning electron microscopy
    da Silva Dalben, Gisele
    Aparecida Francischone, Leda
    Prieto-Oliveira, Paula
    Consolaro, Alberto
    CLINICAL ORAL INVESTIGATIONS, 2008, 12 (03) : 287 - 290