DESIGN, CONSTRUCTION, AND IMPLEMENTATION OF SPHERICAL TISSUE-EQUIVALENT PROPORTIONAL COUNTER

被引:4
|
作者
Perez-Nunez, Delia [1 ]
Braby, Leslie A. [1 ]
机构
[1] Texas A&M Univ, Dept Nucl Engn, College Stn, TX 77843 USA
关键词
detector resolution; microdosimetry; spherical TEPC;
D O I
10.13182/NT09-A9095
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this work a new single anode spherical tissue-equivalent proportional counter (TEPC) was developed for mixed field radiation dosimetry. The approach used was to divide the cathode into several rings with different thicknesses and adjust the potential difference between each ring and the anode to produce an electric field that is nearly constant along the length of the anode. A-150 tissue-equivalent plastic is used for the detector walls, the insulator material between the cathode rings is low-density polyethylene, and the gas inside the detector is propane. The detector, along with the charge sensitive preamplifier, is encased in a stainless steel vacuum chamber. This 1.8-cm-diam TEPC provides low electronic noise, a gas gain of 550 at 782 V, good spectral resolution (26 keV/mu m), and a full-width at half-maximum value of 17%. This spherical TEPC detector system will improve the accuracy of dosimetry in space and as a result improve radiation safety for astronauts.
引用
收藏
页码:21 / 28
页数:8
相关论文
共 50 条
  • [41] TISSUE-EQUIVALENT PROPORTIONAL COUNTERS IN NEUTRON SHIELD EFFECTIVENESS STUDIES
    BRACKENB.LW
    ENDRES, GWR
    FAUST, LG
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1970, 13 (01): : 418 - &
  • [42] Response of a tissue equivalent proportional counter to neutrons
    Badhwar, GD
    Robbins, DE
    Gibbons, F
    Braby, LA
    RADIATION MEASUREMENTS, 2002, 35 (06) : 551 - 556
  • [43] THE TISSUE EQUIVALENT PROPORTIONAL COUNTER NEUTRON MONITOR
    SMITH, RC
    STORDE, JN
    HEALTH PHYSICS, 1980, 39 (06): : 1064 - 1064
  • [44] PERFORMANCE OF A NEUTRON DOSIMETER BASED ON A TISSUE-EQUIVALENT PROPORTIONAL CHAMBER
    EISEN, Y
    BRAKE, R
    VASILIK, D
    ERKKILA, B
    LITTLEJOHN, G
    HEALTH PHYSICS, 1984, 47 (01): : 171 - 171
  • [45] MCNP modelling of the wall effects observed in tissue-equivalent proportional counters
    Hoff, JL
    Townsend, LW
    RADIATION PROTECTION DOSIMETRY, 2002, 99 (1-4) : 369 - 370
  • [46] Microdosimetry with tissue-equivalent proportional counters at an ion beam therapy facility
    Barna, S.
    Meouchi, C.
    Magrin, G.
    Conte, V.
    Stock, M.
    Resch, A.
    Georg, D.
    Palmans, H.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S735 - S736
  • [47] Characterization of miniature tissue-equivalent proportional counters for neutron radiotherapy applications
    Burmeister, J
    Kota, C
    Maughan, RL
    Waker, AJ
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (10): : 1633 - 1645
  • [48] Measurement of lineal-energy distributions for neutrons of 8 keV to 65 MeV by using a tissue-equivalent proportional counter
    Nunomiya, T
    Kim, E
    Kurosawa, T
    Taniguchi, S
    Nakamura, T
    Nakane, Y
    Sakamoto, Y
    Tanaka, S
    RADIATION PROTECTION DOSIMETRY, 2002, 102 (01) : 49 - 59
  • [49] Calibration and background measurements with a tissue equivalent proportional counter
    Autischer, M.
    Beck, P.
    Kindl, P.
    Latocha, M.
    Rollet, S.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 429 - 432
  • [50] THE DOSE EQUIVALENT RESPONSE OF TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS TO LOW-ENERGY NEUTRONS
    SCHUHMACHER, H
    KUNZ, A
    MENZEL, HG
    COYNE, JJ
    SCHWARTZ, RB
    RADIATION PROTECTION DOSIMETRY, 1990, 31 (1-4) : 383 - 387