DESIGN, CONSTRUCTION, AND IMPLEMENTATION OF SPHERICAL TISSUE-EQUIVALENT PROPORTIONAL COUNTER

被引:4
|
作者
Perez-Nunez, Delia [1 ]
Braby, Leslie A. [1 ]
机构
[1] Texas A&M Univ, Dept Nucl Engn, College Stn, TX 77843 USA
关键词
detector resolution; microdosimetry; spherical TEPC;
D O I
10.13182/NT09-A9095
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this work a new single anode spherical tissue-equivalent proportional counter (TEPC) was developed for mixed field radiation dosimetry. The approach used was to divide the cathode into several rings with different thicknesses and adjust the potential difference between each ring and the anode to produce an electric field that is nearly constant along the length of the anode. A-150 tissue-equivalent plastic is used for the detector walls, the insulator material between the cathode rings is low-density polyethylene, and the gas inside the detector is propane. The detector, along with the charge sensitive preamplifier, is encased in a stainless steel vacuum chamber. This 1.8-cm-diam TEPC provides low electronic noise, a gas gain of 550 at 782 V, good spectral resolution (26 keV/mu m), and a full-width at half-maximum value of 17%. This spherical TEPC detector system will improve the accuracy of dosimetry in space and as a result improve radiation safety for astronauts.
引用
收藏
页码:21 / 28
页数:8
相关论文
共 50 条
  • [21] Development of a spherical tissue equivalent proportional counter for neutron monitoring
    姜志刚
    袁永刚
    王和义
    陈华
    Nuclear Science and Techniques, 2015, 26 (06) : 92 - 96
  • [22] Development of a spherical tissue equivalent proportional counter for neutron monitoring
    Jiang Zhi-Gang
    Yuan Yong-Gang
    Wang He-Yi
    Chen Hua
    NUCLEAR SCIENCE AND TECHNIQUES, 2015, 26 (06)
  • [24] A TISSUE-EQUIVALENT PROPORTIONAL COUNTER FOR SEPARATING DOSES DUE TO GAMMA AND NEUTRON RADIATION
    ENDRES, GWR
    HAVERFIE.AJ
    GLASS, WA
    HEALTH PHYSICS, 1968, 15 (02): : 195 - +
  • [25] Design and preliminary test of a multi-element tissue-equivalent proportional counter based on the gas electron multiplier
    Zhang, Weihua
    Li, Chunjuan
    Wang, Zhiqiang
    Qi, Huirong
    Zou, Yisheng
    Liu, Yina
    Luo, Hailong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 916 : 37 - 41
  • [26] Application of low-pressure tissue-equivalent proportional counter in IHEP radiation protection
    Alekseev, AG
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D578 - D578
  • [27] OPTIMIZATION OF THE ELECTRIC-FIELD DISTRIBUTION IN A LARGE VOLUME TISSUE-EQUIVALENT PROPORTIONAL COUNTER
    VERMA, PK
    WAKER, AJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10): : 1837 - 1846
  • [28] Tissue-equivalent proportional counters in radiation protection
    McDonald, JC
    RADIATION PROTECTION DOSIMETRY, 1998, 77 (03) : 147 - 149
  • [29] Numerical modelling of tissue-equivalent proportional counters
    Segur, P
    Olko, P
    Colautti, P
    RADIATION PROTECTION DOSIMETRY, 1995, 61 (04) : 323 - 350
  • [30] Operation and application of tissue-equivalent proportional counters
    Gerdung, S
    Pihet, P
    Grindborg, JE
    Roos, H
    Schrewe, UJ
    Schuhmacher, H
    RADIATION PROTECTION DOSIMETRY, 1995, 61 (04) : 381 - 404