DESIGN, CONSTRUCTION, AND IMPLEMENTATION OF SPHERICAL TISSUE-EQUIVALENT PROPORTIONAL COUNTER

被引:4
|
作者
Perez-Nunez, Delia [1 ]
Braby, Leslie A. [1 ]
机构
[1] Texas A&M Univ, Dept Nucl Engn, College Stn, TX 77843 USA
关键词
detector resolution; microdosimetry; spherical TEPC;
D O I
10.13182/NT09-A9095
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this work a new single anode spherical tissue-equivalent proportional counter (TEPC) was developed for mixed field radiation dosimetry. The approach used was to divide the cathode into several rings with different thicknesses and adjust the potential difference between each ring and the anode to produce an electric field that is nearly constant along the length of the anode. A-150 tissue-equivalent plastic is used for the detector walls, the insulator material between the cathode rings is low-density polyethylene, and the gas inside the detector is propane. The detector, along with the charge sensitive preamplifier, is encased in a stainless steel vacuum chamber. This 1.8-cm-diam TEPC provides low electronic noise, a gas gain of 550 at 782 V, good spectral resolution (26 keV/mu m), and a full-width at half-maximum value of 17%. This spherical TEPC detector system will improve the accuracy of dosimetry in space and as a result improve radiation safety for astronauts.
引用
收藏
页码:21 / 28
页数:8
相关论文
共 50 条
  • [1] Optimized design of tissue-equivalent proportional counter
    Zhang, Wei-Hua
    Wang, Zhi-Qiang
    Xiao, Xue-Fu
    Liu, Yi-Na
    Li, Chun-Juan
    Luo, Hai-Long
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2014, 48 (05): : 930 - 933
  • [2] CONSTRUCTION AND TEST OF A PORTABLE TISSUE-EQUIVALENT PROPORTIONAL COUNTER SYSTEM
    Zhang, Weihua
    Ni, Ning
    Wang, Zhiqiang
    Liu, Yina
    Li, Chunjuan
    Luo, Hailong
    RADIATION PROTECTION DOSIMETRY, 2018, 179 (01) : 95 - 100
  • [3] MEASUREMENT OF LET SPECTRA USING A SPHERICAL TISSUE-EQUIVALENT PROPORTIONAL COUNTER
    WILSON, KSJ
    FIELD, SB
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (04): : 657 - &
  • [4] SPHERICAL TISSUE-EQUIVALENT PROPORTIONAL COUNTER WITH COAXIAL ELECTRIC-FIELD
    BELONOGII, PN
    DROBCHENKO, EA
    KHARLAMOV, AD
    MEASUREMENT TECHNIQUES, 1985, 28 (10) : 901 - 903
  • [5] A practical design of a cylindrical tissue-equivalent proportional counter for microdosimetry
    Martin, G
    Gerdung, S
    Raabe, M
    Arend, E
    RADIATION PROTECTION DOSIMETRY, 2002, 99 (1-4) : 379 - 380
  • [6] Practical considerations in the design and construction of tissue-equivalent proportional counters
    Braby, LA
    Johnson, GW
    Barthe, J
    RADIATION PROTECTION DOSIMETRY, 1995, 61 (04) : 351 - 379
  • [7] Design of tissue-equivalent proportional counters
    Kliauga, P
    Waker, AJ
    Barthe, J
    RADIATION PROTECTION DOSIMETRY, 1995, 61 (04) : 309 - 322
  • [8] UNIVERSAL EQUIDOSIMETER BASED ON A TISSUE-EQUIVALENT PROPORTIONAL COUNTER
    GARTSHTEIN, AI
    MAKOVSKII, YE
    FILYUSHKIN, IV
    MEASUREMENT TECHNIQUES, 1981, 24 (04) : 328 - 330
  • [9] Design of a new tissue-equivalent proportional counter based on a gas electron multiplier
    Farahmand, M
    Bos, AJJ
    Huizenga, J
    De Nardo, L
    van Eijk, CWE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3): : 262 - 267
  • [10] The response of a spherical tissue-equivalent proportional counter to different heavy ions having similar velocities
    Taddei, Phillip J.
    Borak, Thomas B.
    Guetersloh, Stephen B.
    Gersey, Brad B.
    Zeitlin, Cary
    Heilbronn, Lawrence
    Miller, Jack
    Murakami, Takeshi
    Iwata, Yoshiyuki
    RADIATION MEASUREMENTS, 2006, 41 (9-10) : 1227 - 1234