CONSTRUCTION AND TEST OF A PORTABLE TISSUE-EQUIVALENT PROPORTIONAL COUNTER SYSTEM

被引:3
|
作者
Zhang, Weihua [1 ]
Ni, Ning [1 ]
Wang, Zhiqiang [1 ]
Liu, Yina [1 ]
Li, Chunjuan [1 ]
Luo, Hailong [1 ]
机构
[1] China Inst Atom Energy, Radiat Metrol Dept, Beijing 102413, Peoples R China
关键词
DIFFERENT DOSIMETERS; COSMIC-RADIATION; ALTITUDES; H-ASTERISK(10);
D O I
10.1093/rpd/ncx214
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Tissue-equivalent proportional counter (TEPC) is a very promising dosemeter for radiation protection in mixed radiation fields. In this article, a portable TEPC system including a spherical homemade TEPC detector and the compact low-power integrated circuit prototype was constructed and tested in gamma and neutron radiation fields. The microdosimetric spectra results displayed that the portable TEPC system could deal with four orders of magnitude voltage pulse signals. And the measured dose equivalent values agreed with reference values, which means the portable TEPC system had fulfilled the test and satisfied the requirement for radiation monitor.
引用
收藏
页码:95 / 100
页数:6
相关论文
共 50 条
  • [1] DESIGN, CONSTRUCTION, AND IMPLEMENTATION OF SPHERICAL TISSUE-EQUIVALENT PROPORTIONAL COUNTER
    Perez-Nunez, Delia
    Braby, Leslie A.
    NUCLEAR TECHNOLOGY, 2009, 168 (01) : 21 - 28
  • [2] Optimized design of tissue-equivalent proportional counter
    Zhang, Wei-Hua
    Wang, Zhi-Qiang
    Xiao, Xue-Fu
    Liu, Yi-Na
    Li, Chun-Juan
    Luo, Hai-Long
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2014, 48 (05): : 930 - 933
  • [3] UNIVERSAL EQUIDOSIMETER BASED ON A TISSUE-EQUIVALENT PROPORTIONAL COUNTER
    GARTSHTEIN, AI
    MAKOVSKII, YE
    FILYUSHKIN, IV
    MEASUREMENT TECHNIQUES, 1981, 24 (04) : 328 - 330
  • [4] Simulated Response of a Tissue-equivalent Proportional Counter on the Surface of Mars
    Northum, Jeremy D.
    Guetersloh, Stephen B.
    Braby, Leslie A.
    Ford, John R.
    HEALTH PHYSICS, 2015, 109 (04): : 284 - 295
  • [5] REPLACEMENT TISSUE-EQUIVALENT PROPORTIONAL COUNTER FOR THE INTERNATIONAL SPACE STATION
    Perez-Nunez, D.
    Braby, L. A.
    RADIATION PROTECTION DOSIMETRY, 2011, 143 (2-4) : 394 - 397
  • [6] CONSTRUCTION OF A SELF-SUPPORTING TISSUE-EQUIVALENT DIVIDING WALL AND OPERATIONAL CHARACTERISTICS OF A COAXIAL DOUBLE-CYLINDRICAL TISSUE-EQUIVALENT PROPORTIONAL COUNTER
    SAION, EB
    WATT, DE
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1994, 5 (04) : 379 - 383
  • [7] A practical design of a cylindrical tissue-equivalent proportional counter for microdosimetry
    Martin, G
    Gerdung, S
    Raabe, M
    Arend, E
    RADIATION PROTECTION DOSIMETRY, 2002, 99 (1-4) : 379 - 380
  • [8] MEASUREMENT OF LET SPECTRA USING A SPHERICAL TISSUE-EQUIVALENT PROPORTIONAL COUNTER
    WILSON, KSJ
    FIELD, SB
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (04): : 657 - &
  • [9] Performance of a cylindrical tissue-equivalent proportional counter for use in neutron monitoring
    Chau, Q
    Lahaye, T
    Ménard, S
    Donadille, L
    Bolognese, T
    Rannou, A
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 297 - 300
  • [10] SPHERICAL TISSUE-EQUIVALENT PROPORTIONAL COUNTER WITH COAXIAL ELECTRIC-FIELD
    BELONOGII, PN
    DROBCHENKO, EA
    KHARLAMOV, AD
    MEASUREMENT TECHNIQUES, 1985, 28 (10) : 901 - 903