A modular phantom and software to characterize 3D geometric distortion in MRI

被引:12
|
作者
Slagowski, Jordan M. [1 ]
Ding, Yao [2 ]
Aima, Manik [1 ]
Wen, Zhifei [1 ]
Fuller, Clifton D. [2 ]
Chung, Caroline [2 ]
Debnam, J. Matthew [3 ]
Hwang, Ken-Pin [4 ]
Kadbi, Mo [5 ]
Szklaruk, Janio [6 ]
Wang, Jihong [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Neuroradiol, Houston, TX 77030 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[5] Philips HealthTech, MR Therapy, Cleveland, OH USA
[6] Univ Texas MD Anderson Canc Ctr, Dept Abdominal Imaging, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 19期
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
MR-guided radiation therapy; MRI; geometric distortion; gradient non-linearity; RADIATION-THERAPY; CT; LOCALIZATION;
D O I
10.1088/1361-6560/ab9c64
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic resonance imaging (MRI) offers outstanding soft tissue contrast that may reduce uncertainties in target and organ-at-risk delineation and enable online adaptive image-guided treatment. Spatial distortions resulting from non-linearities in the gradient fields and non-uniformity in the main magnetic field must be accounted for across the imaging field-of-view to prevent systematic errors during treatment delivery. This work presents a modular phantom and software application to characterize geometric distortion (GD) within the large field-of-view MRI images required for radiation therapy simulation. The modular phantom is assembled from a series of rectangular foam blocks containing high-contrast fiducial markers in a known configuration. The modular phantom design facilitates transportation of the phantom between different MR scanners and MR-guided linear accelerators and allows the phantom to be adapted to fit different sized bores or coils. The phantom was evaluated using a 1.5 T MR-guided linear accelerator (MR-Linac) and 1.5 T and 3.0 T diagnostic scanners. Performance was assessed by varying acquisition parameters to induce image distortions in a known manner. Imaging was performed using T1 and T2 weighted pulse sequences with 2D and 3D distortion correction algorithms and the receiver bandwidth (BW) varied as 250-815 Hz pixel(-1). Phantom set-up reproducibility was evaluated across independent set-ups. The software was validated by comparison with a non-modular phantom. Average geometric distortion was 0.94 +/- 0.58 mm for the MR-Linac, 0.90 +/- 0.53 mm for the 1.5 T scanner, and 1.15 +/- 0.62 mm for the 3.0 T scanner, for a 400 mm diameter volume-of-interest. GD increased, as expected, with decreasing BW, and with the 2D versus 3D correction algorithm. Differences in GD attributed to phantom set-up were 0.13 mm or less. Differences in GD for the two software applications were less than 0.07 mm. A novel modular phantom was developed to evaluate distortions in MR images for radiation therapy applications.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Low Cost MRI Geometric Distortion Phantom Made From Paintballs and Pourable Foam
    Rasmussen, B.
    Du, X.
    Milano, R.
    MEDICAL PHYSICS, 2020, 47 (06) : E636 - E636
  • [22] Assessment of geometric distortion in six clinical scanners using a 3D-printed grid phantom
    Jafar M.
    Jafar Y.M.
    Dean C.
    Miquel M.E.
    Miquel, Marc E. (marc.miquel@bartshealth.nhs.uk), 2017, MDPI (03)
  • [23] 2D & 3D Shepp-Logan phantom standards for MRI
    Gach, H. Michael
    Tanase, Costin
    Boada, Femando
    ICSENG 2008: INTERNATIONAL CONFERENCE ON SYSTEMS ENGINEERING, 2008, : 521 - +
  • [24] Design and evaluation of a diffusion MRI fibre phantom using 3D printing
    Abu-Sardanah, Serene O.
    Hussain, Uzair
    Moore, John
    Baron, Corey
    Peters, Terry
    Khan, Ali R.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [25] 3D quantification of metal-induced geometric distortions in MRI
    Li, Hao
    Oezen, Ali C.
    Juerchott, Alexander
    Breckwoldt, Michael
    Jesser, Jessica
    Vollherbst, Dominik F.
    Schwarz, Daniel
    Bendszus, Martin
    Heiland, Sabine
    Hilgenfeld, Tim
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [26] Characterizing geometric distortions of 3D sequences in clinical head MRI
    Nousiainen, Katri
    Makela, Teemu
    Peltonen, Juha, I
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2022, 35 (06) : 983 - 995
  • [27] Characterizing geometric distortions of 3D sequences in clinical head MRI
    Katri Nousiainen
    Teemu Mäkelä
    Juha I. Peltonen
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2022, 35 : 983 - 995
  • [28] A Modular Software System for 3D Measurement of Acetabulum in Arthritic Dysplasia Hips
    Chen, Chulan
    Wu, Peihui
    Zheng, Linli
    Liu, Yuanping
    Zhang, Xiaoyan
    Song, Yukai
    2019 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE (BIBM), 2019, : 1449 - 1456
  • [29] Parallel Geometric Multigrid Preconditioner for 3D FEM in NuscaS Software Package
    Olas, Tomasz
    PARALLEL PROCESSING AND APPLIED MATHEMATICS (PPAM 2013), PT I, 2014, 8384 : 166 - 177
  • [30] Geometric distortion evaluation using a multi-orientated water-phantom at 0.2 T MRI
    Jao, Jochi
    Cheng, Mingye
    Lee, Hsintien
    Ting, Julius
    Chen, Pochou
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S1431 - S1438