Geometric distortion evaluation using a multi-orientated water-phantom at 0.2 T MRI

被引:1
|
作者
Jao, Jochi [1 ]
Cheng, Mingye [2 ]
Lee, Hsintien [2 ]
Ting, Julius [2 ]
Chen, Pochou [3 ]
机构
[1] Kaohsiung Med Univ, Coll Hlth Sci, Dept Med Imaging & Radiol Sci, Kaohsiung 80708, Taiwan
[2] Antai Med Care Cooperat Antai Tian Sheng Mem Hosp, Dept Radiol, Donggang Township 928, Pingtung County, Taiwan
[3] I Shou Univ, Dept Biomed Engn, Kaohsiung 82445, Taiwan
关键词
Geometric distortion; field inhomogeneity; off-center field; multi-orientated water-phantom; PROSTATE-CANCER; 3D PHANTOM; SYSTEMS;
D O I
10.3233/BME-151441
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic Resonance Imaging (MRI) has been one of the most revolutionary medical imaging modalities in the past three decades. It has been recognized as a potential technique in the clinical diagnosis of diseases as well as tumor differentiation. Although MRI has now become the preferred choice in many clinical examinations, there are some drawbacks, which still limit its applications. One of the crucial issues of MRI is the geometric distortion caused by magnetic field inhomogeneity and susceptibility effects. The farther the lesion from the center of a magnetic field (off-center field), the more severe the distortion becomes, especially in low-field MRI. Hence, it might hinder the diagnosis and characterization of lesions in the presence of field inhomogeneity. In this study, an innovative multi-orientated water-phantom was used to evaluate the geometric distortion. The correlations between the level of image distortion and the relative off-center positions, as well as the variation of signal intensities, were both investigated. The image distortion ratios of axial, coronal and sagittal images were calculated.
引用
收藏
页码:S1431 / S1438
页数:8
相关论文
共 21 条
  • [1] Versatile Geometric Distortion Evaluation of MRI Using Modular Phantom with LEGO Compatibility in Radiation Therapy
    Hong, C.
    Cho, H.
    Lee, C.
    Ahn, B.
    MEDICAL PHYSICS, 2020, 47 (06) : E671 - E671
  • [2] Geometric distortion in clinical MRI systems - Part I: evaluation using a 3D phantom
    Wang, D
    Strugnell, W
    Cowin, G
    Doddrell, DM
    Slaughter, R
    MAGNETIC RESONANCE IMAGING, 2004, 22 (09) : 1211 - 1221
  • [3] Effects of geometric distortion in 0.2 T MRI on radiotherapy treatment planning of prostate cancer
    Petersch, B
    Bogner, J
    Fransson, A
    Lorang, T
    Pötter, R
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 (01) : 55 - 64
  • [4] Geometric Distortion at 3T in a Commercial 4D MRI-Compatible Phantom
    Fatemi-Ardekani, A.
    Wronski, M.
    Kim, A.
    Stanisz, G.
    Sarfehnia, A.
    Keller, B.
    MEDICAL PHYSICS, 2015, 42 (06) : 3313 - 3313
  • [5] Evaluation of Geometric Distortion in 7T MRI for Frameless Surgical Procedures
    Kirby, K.
    Welker, K.
    Koons, E.
    Fagan, A.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [6] Estimation of system-related geometric distortion in 7T MRI using a 3D anthropomorphic head phantom
    Peerlings, J.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S455 - S455
  • [7] Geometric distortion in clinical MRI systems - Part II: correction using a 3D phantom
    Wang, D
    Strugnell, W
    Cowin, G
    Doddrell, DM
    Slaughter, R
    MAGNETIC RESONANCE IMAGING, 2004, 22 (09) : 1223 - 1232
  • [8] Investigation of Geometric Image Distortion Correction Using the Bricks Phantom for Multi-Modality Imaging
    Hong, C.
    Cho, H.
    Lee, D.
    Ahn, B.
    MEDICAL PHYSICS, 2014, 41 (06) : 138 - +
  • [9] Analysis of geometric Distortions and their Corrections in MR Data by using a multimodal Phantom on a 3T-MRI
    Madesta, F.
    Gargioni, E.
    Peldschus, K.
    Gauer, T.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 : 96 - 96
  • [10] Multi-site, multi-platform comparison of MRI T1 measurement using the system phantom
    Keenan, Kathryn E.
    Gimbutas, Zydrunas
    Dienstfrey, Andrew
    Stupic, Karl F.
    Boss, Michael A.
    Russek, Stephen E.
    Chenevert, Thomas L.
    Prasad, P., V
    Guo, Junyu
    Reddick, Wilburn E.
    Cecil, Kim M.
    Shukla-Dave, Amita
    Nunez, David Aramburu
    Konar, Amaresh Shridhar
    Liu, Michael Z.
    Jambawalikar, Sachin R.
    Schwartz, Lawrence H.
    Zheng, Jie
    Hu, Peng
    Jackson, Edward F.
    PLOS ONE, 2021, 16 (06):