A modular phantom and software to characterize 3D geometric distortion in MRI

被引:12
|
作者
Slagowski, Jordan M. [1 ]
Ding, Yao [2 ]
Aima, Manik [1 ]
Wen, Zhifei [1 ]
Fuller, Clifton D. [2 ]
Chung, Caroline [2 ]
Debnam, J. Matthew [3 ]
Hwang, Ken-Pin [4 ]
Kadbi, Mo [5 ]
Szklaruk, Janio [6 ]
Wang, Jihong [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Neuroradiol, Houston, TX 77030 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[5] Philips HealthTech, MR Therapy, Cleveland, OH USA
[6] Univ Texas MD Anderson Canc Ctr, Dept Abdominal Imaging, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 19期
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
MR-guided radiation therapy; MRI; geometric distortion; gradient non-linearity; RADIATION-THERAPY; CT; LOCALIZATION;
D O I
10.1088/1361-6560/ab9c64
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic resonance imaging (MRI) offers outstanding soft tissue contrast that may reduce uncertainties in target and organ-at-risk delineation and enable online adaptive image-guided treatment. Spatial distortions resulting from non-linearities in the gradient fields and non-uniformity in the main magnetic field must be accounted for across the imaging field-of-view to prevent systematic errors during treatment delivery. This work presents a modular phantom and software application to characterize geometric distortion (GD) within the large field-of-view MRI images required for radiation therapy simulation. The modular phantom is assembled from a series of rectangular foam blocks containing high-contrast fiducial markers in a known configuration. The modular phantom design facilitates transportation of the phantom between different MR scanners and MR-guided linear accelerators and allows the phantom to be adapted to fit different sized bores or coils. The phantom was evaluated using a 1.5 T MR-guided linear accelerator (MR-Linac) and 1.5 T and 3.0 T diagnostic scanners. Performance was assessed by varying acquisition parameters to induce image distortions in a known manner. Imaging was performed using T1 and T2 weighted pulse sequences with 2D and 3D distortion correction algorithms and the receiver bandwidth (BW) varied as 250-815 Hz pixel(-1). Phantom set-up reproducibility was evaluated across independent set-ups. The software was validated by comparison with a non-modular phantom. Average geometric distortion was 0.94 +/- 0.58 mm for the MR-Linac, 0.90 +/- 0.53 mm for the 1.5 T scanner, and 1.15 +/- 0.62 mm for the 3.0 T scanner, for a 400 mm diameter volume-of-interest. GD increased, as expected, with decreasing BW, and with the 2D versus 3D correction algorithm. Differences in GD attributed to phantom set-up were 0.13 mm or less. Differences in GD for the two software applications were less than 0.07 mm. A novel modular phantom was developed to evaluate distortions in MR images for radiation therapy applications.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] 3D geometric split-merge segmentation of brain MRI datasets
    Marras, Ioannis
    Nikolaidis, Nikolaos
    Pitas, Ioannis
    COMPUTERS IN BIOLOGY AND MEDICINE, 2014, 48 : 119 - 132
  • [32] Design and implementation of a 3D-MR/CT geometric image distortion phantom/analysis system for stereotactic radiosurgery
    Damyanovich, A. Z.
    Rieker, M.
    Zhang, B.
    Bissonnette, J-P
    Jaffray, D. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (07):
  • [33] Fabrication of A 3D Moving Phantom
    Huh, S.
    Duvvuri, S.
    Palta, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [34] 3D SlicerUniverselle 3D-Visualisierung-Software3D SlicerUniversal 3D visualization software
    Nico Bruns
    Der Unfallchirurg, 2019, 122 (8): : 662 - 663
  • [35] Evaluation of a Novel 3D Distortion and Quality Control Phantom for MR-Guided Radiation Therapy
    Antolak, A.
    Paliwal, B.
    Jackson, E.
    Mallozzi, R.
    Yadav, P.
    MEDICAL PHYSICS, 2018, 45 (06) : E544 - E544
  • [36] Comparison of Residual Distortions for MRI Sequences On a 3T MRI Unit Using a 3D Rectilinear Grid Phantom
    Molina, F. Diaz
    Cao, Y.
    Klein, E.
    Knisely, J.
    Gill, G.
    Marrero, M.
    Schulder, M.
    Kirsch, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3447 - 3447
  • [37] Open-source hardware and software for the measurement, characterization, reporting, and correction of geometric distortion in MRI
    Whelan, Brendan M.
    Liu, Paul Z. Y.
    Shan, Shanshan
    Waddington, David E. J.
    Dong, Bin
    Jameson, Michael G.
    Keall, Paul J.
    MEDICAL PHYSICS, 2024, 51 (11) : 8399 - 8410
  • [38] Development and Evaluation of a 3D Printed Modular Phantom of the Lower Extremities for Optimization and Evaluation of TBI Techniques
    Wegner, M.
    Azbari, N. Alizadeh
    Krause, D.
    Gargioni, E.
    MEDICAL PHYSICS, 2024, 51 (10) : 7967 - 7967
  • [39] Use of a 3D geometric software on the performance of 11th grade students
    Roussey, JY
    Chaleppe, M
    Piolat, A
    INTERNATIONAL JOURNAL OF PSYCHOLOGY, 1996, 31 (3-4) : 54159 - 54159
  • [40] Developing a 3D Printed Phantom for Multi-Institutional Radiomic Studies and Assessment Software to Evaluate a Radiomic Software
    Duong, S.
    Lee, D.
    Oh, S.
    Chen, X.
    Hwang, M.
    Li, H.
    Cui, Y.
    Boss, M.
    Xiao, Y.
    Sohn, J.
    MEDICAL PHYSICS, 2022, 49 (06) : E644 - E645