A modular phantom and software to characterize 3D geometric distortion in MRI

被引:12
|
作者
Slagowski, Jordan M. [1 ]
Ding, Yao [2 ]
Aima, Manik [1 ]
Wen, Zhifei [1 ]
Fuller, Clifton D. [2 ]
Chung, Caroline [2 ]
Debnam, J. Matthew [3 ]
Hwang, Ken-Pin [4 ]
Kadbi, Mo [5 ]
Szklaruk, Janio [6 ]
Wang, Jihong [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Neuroradiol, Houston, TX 77030 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[5] Philips HealthTech, MR Therapy, Cleveland, OH USA
[6] Univ Texas MD Anderson Canc Ctr, Dept Abdominal Imaging, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 19期
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
MR-guided radiation therapy; MRI; geometric distortion; gradient non-linearity; RADIATION-THERAPY; CT; LOCALIZATION;
D O I
10.1088/1361-6560/ab9c64
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic resonance imaging (MRI) offers outstanding soft tissue contrast that may reduce uncertainties in target and organ-at-risk delineation and enable online adaptive image-guided treatment. Spatial distortions resulting from non-linearities in the gradient fields and non-uniformity in the main magnetic field must be accounted for across the imaging field-of-view to prevent systematic errors during treatment delivery. This work presents a modular phantom and software application to characterize geometric distortion (GD) within the large field-of-view MRI images required for radiation therapy simulation. The modular phantom is assembled from a series of rectangular foam blocks containing high-contrast fiducial markers in a known configuration. The modular phantom design facilitates transportation of the phantom between different MR scanners and MR-guided linear accelerators and allows the phantom to be adapted to fit different sized bores or coils. The phantom was evaluated using a 1.5 T MR-guided linear accelerator (MR-Linac) and 1.5 T and 3.0 T diagnostic scanners. Performance was assessed by varying acquisition parameters to induce image distortions in a known manner. Imaging was performed using T1 and T2 weighted pulse sequences with 2D and 3D distortion correction algorithms and the receiver bandwidth (BW) varied as 250-815 Hz pixel(-1). Phantom set-up reproducibility was evaluated across independent set-ups. The software was validated by comparison with a non-modular phantom. Average geometric distortion was 0.94 +/- 0.58 mm for the MR-Linac, 0.90 +/- 0.53 mm for the 1.5 T scanner, and 1.15 +/- 0.62 mm for the 3.0 T scanner, for a 400 mm diameter volume-of-interest. GD increased, as expected, with decreasing BW, and with the 2D versus 3D correction algorithm. Differences in GD attributed to phantom set-up were 0.13 mm or less. Differences in GD for the two software applications were less than 0.07 mm. A novel modular phantom was developed to evaluate distortions in MR images for radiation therapy applications.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] A 3D printed phantom to assess MRI geometric distortion
    Ramachandran, Prabhakar
    Noble, Christopher
    Langton, Christian
    Perrett, Ben
    Cox, Joshua
    Chapman, Mike
    McGill, George
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (03):
  • [2] Geometric Distortion Correction of MRI-Linac Phantom with 3d Printing Phantom
    Liu, X.
    Jia, C.
    Li, H.
    Shi, L.
    Lu, W.
    Gong, G.
    Li, Z.
    Yin, Y.
    Qiu, J.
    MEDICAL PHYSICS, 2019, 46 (06) : E141 - E141
  • [3] Geometric distortion in clinical MRI systems - Part I: evaluation using a 3D phantom
    Wang, D
    Strugnell, W
    Cowin, G
    Doddrell, DM
    Slaughter, R
    MAGNETIC RESONANCE IMAGING, 2004, 22 (09) : 1211 - 1221
  • [4] Geometric distortion in clinical MRI systems - Part II: correction using a 3D phantom
    Wang, D
    Strugnell, W
    Cowin, G
    Doddrell, DM
    Slaughter, R
    MAGNETIC RESONANCE IMAGING, 2004, 22 (09) : 1223 - 1232
  • [5] DESIGN OF A NEW 3D GEOMETRIC DISTORTION PHANTOM FOR MR IMAGING
    KESSLER, ML
    CARSON, PL
    CHENEVERT, TL
    TENHAKEN, RK
    RADIOLOGY, 1992, 185 : 223 - 224
  • [6] Compare the 3D Geometric Distortion of MRI, MR-sim and MR-Linac Systems by 3D Printed Phantom
    Liu, X.
    Li, Z.
    Jia, C.
    Yin, Y.
    Qiu, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E259 - E259
  • [7] Versatile Geometric Distortion Evaluation of MRI Using Modular Phantom with LEGO Compatibility in Radiation Therapy
    Hong, C.
    Cho, H.
    Lee, C.
    Ahn, B.
    MEDICAL PHYSICS, 2020, 47 (06) : E671 - E671
  • [8] Estimation of system-related geometric distortion in 7T MRI using a 3D anthropomorphic head phantom
    Peerlings, J.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S455 - S455
  • [9] Characterization of 3D geometric distortion of MRI scanners commissioned for RT planning
    Torfeh, T.
    Perkins, G.
    Hammoud, R.
    McGarry, M.
    Celik, A.
    Hwang, K.
    Stancanello, J.
    Al-Hammadi, N.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S842 - S842
  • [10] Geometric Distortion at 3T in a Commercial 4D MRI-Compatible Phantom
    Fatemi-Ardekani, A.
    Wronski, M.
    Kim, A.
    Stanisz, G.
    Sarfehnia, A.
    Keller, B.
    MEDICAL PHYSICS, 2015, 42 (06) : 3313 - 3313