Assessing and Improving Cobalt-60 Digital Tomosynthesis Image Quality

被引:0
|
作者
Marsh, Matthew B. [1 ]
Schreiner, L. John [1 ]
Kerr, Andrew T. [1 ]
机构
[1] Queens Univ, Canc Ctr Southeastern Ontario, Dept Med Phys, Kingston, ON, Canada
关键词
Image guidance; radiation therapy; cobalt-60; tomosynthesis; IGRT; patient positioning; BEAM COMPUTED-TOMOGRAPHY; GUIDED RADIATION-THERAPY; CBDT; RADIOGRAPHY;
D O I
10.1117/12.2043066
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Image guidance capability is an important feature of modern radiotherapy linacs, and future cobalt-60 units will be expected to have similar capabilities. Imaging with the treatment beam is an appealing option, for reasons of simplicity and cost, but the dose needed to produce cone beam CT (CBCT) images in a Co-60 treatment beam is too high for this modality to be clinically useful. Digital tomosynthesis (DT) offers a quasi-3D image, of sufficient quality to identify bony anatomy or fiducial markers, while delivering a much lower dose than CBCT. A series of experiments were conducted on a prototype Co-60 cone beam imaging system to quantify the resolution, selectivity, geometric accuracy and contrast sensitivity of Co-60 DT. Although the resolution is severely limited by the penumbra cast by the 2 cm diameter source, it is possible to identify high contrast objects on the order of 1 mm in width, and bony anatomy in anthropomorphic phantoms is clearly recognizable. Low contrast sensitivity down to electron density differences of 3% is obtained, for uniform features of similar thickness. The conventional shift-and-add reconstruction algorithm was compared to several variants of the Feldkamp-Davis-Kress filtered backprojection algorithm result. The Co-60 DT images were obtained with a total dose of 5 to 15 cGy each. We conclude that Co-60 radiotherapy units upgraded for modern conformal therapy could also incorporate imaging using filtered backprojection DT in the treatment beam. DT is a versatile and promising modality that would be well suited to image guidance requirements.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] COBALT-60 PROTECTION DESIGN
    BRAESTRUP, CB
    MOONEY, RT
    RADIOLOGY, 1955, 65 (06) : 884 - 891
  • [32] RADIOPRESERVATION OF CARTILAGE WITH COBALT-60
    HELLMICH, S
    ARCHIV FUR KLINISCHE UND EXPERIMENTELLE OHREN-NASEN-UND KEHLKOPFHEILKUNDE, 1972, 202 (02): : 670 - 677
  • [33] COBALT-60 IRRADIATION CHAMBER
    GREENFIELD, MA
    SILVERMAN, LB
    DICKINSON, RW
    NUCLEONICS, 1952, 10 (12): : 65 - 67
  • [34] COBALT-60 CAPTATION BY MYCOBACTERIUM
    AVIO, CM
    CAROLI, G
    ANNALI SCLAVO, 1974, 16 (04): : 431 - 432
  • [35] METABOLISM OF COBALT-60 IN CHICKENS
    LEE, CC
    WOLTERINK, LF
    POULTRY SCIENCE, 1955, 34 (04) : 764 - 776
  • [36] ROUGHAGE AND COBALT SOURCE ON COBALT-60 RETENTION
    LOONEY, JW
    GELLE, G
    GRAHAM, ER
    HUTCHESON, DP
    PFANDER, WH
    JOURNAL OF ANIMAL SCIENCE, 1970, 31 (05) : 1040 - +
  • [37] Digital breast tomosynthesis: Dose and image quality assessment
    Maldera, A.
    De Marco, P.
    Colombo, P. E.
    Origgi, D.
    Torresin, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 33 : 56 - 67
  • [38] Effect of acquisition parameters on image quality in digital tomosynthesis
    Deller, Timothy
    Jabri, Kadri N.
    Sabol, John M.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [39] Image quality evaluation and improvement of a digital tomosynthesis system
    Kang, ST
    Cho, HS
    MATERIALS EVALUATION, 1999, 57 (08) : 841 - 845
  • [40] Characterization of image quality in digital tomosynthesis for radiotherapy applications
    Armstrong, Hirotatsu
    Jones, Bernard
    Miften, Moyed
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2016, 2 (02):