Assessing and Improving Cobalt-60 Digital Tomosynthesis Image Quality

被引:0
|
作者
Marsh, Matthew B. [1 ]
Schreiner, L. John [1 ]
Kerr, Andrew T. [1 ]
机构
[1] Queens Univ, Canc Ctr Southeastern Ontario, Dept Med Phys, Kingston, ON, Canada
关键词
Image guidance; radiation therapy; cobalt-60; tomosynthesis; IGRT; patient positioning; BEAM COMPUTED-TOMOGRAPHY; GUIDED RADIATION-THERAPY; CBDT; RADIOGRAPHY;
D O I
10.1117/12.2043066
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Image guidance capability is an important feature of modern radiotherapy linacs, and future cobalt-60 units will be expected to have similar capabilities. Imaging with the treatment beam is an appealing option, for reasons of simplicity and cost, but the dose needed to produce cone beam CT (CBCT) images in a Co-60 treatment beam is too high for this modality to be clinically useful. Digital tomosynthesis (DT) offers a quasi-3D image, of sufficient quality to identify bony anatomy or fiducial markers, while delivering a much lower dose than CBCT. A series of experiments were conducted on a prototype Co-60 cone beam imaging system to quantify the resolution, selectivity, geometric accuracy and contrast sensitivity of Co-60 DT. Although the resolution is severely limited by the penumbra cast by the 2 cm diameter source, it is possible to identify high contrast objects on the order of 1 mm in width, and bony anatomy in anthropomorphic phantoms is clearly recognizable. Low contrast sensitivity down to electron density differences of 3% is obtained, for uniform features of similar thickness. The conventional shift-and-add reconstruction algorithm was compared to several variants of the Feldkamp-Davis-Kress filtered backprojection algorithm result. The Co-60 DT images were obtained with a total dose of 5 to 15 cGy each. We conclude that Co-60 radiotherapy units upgraded for modern conformal therapy could also incorporate imaging using filtered backprojection DT in the treatment beam. DT is a versatile and promising modality that would be well suited to image guidance requirements.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] COBALT-60 TELETHERAPY
    LEDERMAN, M
    BRITISH JOURNAL OF RADIOLOGY, 1965, 38 (450): : 464 - &
  • [12] COBALT-60 RADIOGRAPHY
    PERRYMAN, CR
    MCALLISTER, JD
    BURWELL, JA
    AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1960, 83 (03): : 525 - 532
  • [13] DESIGN OF A DIGITAL CONTROL PANEL FOR A COBALT-60 RADIOTHERAPY UNIT
    WHITE, DR
    MALLION, WE
    OCONNOR, AD
    MEDICAL & BIOLOGICAL ENGINEERING, 1968, 6 (03): : 341 - &
  • [14] RADIOGRAPHY WITH COBALT-60
    MORRISON, A
    NUCLEONICS, 1949, 5 (06): : 19 - 32
  • [15] COBALT-60 TELETHERAPY
    不详
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1965, 92 (21) : 1146 - &
  • [16] A novel pre-processing technique for improving image quality in digital breast tomosynthesis
    Kim, Hyeongseok
    Lee, Taewon
    Hong, Joonpyo
    Sabir, Sohail
    Lee, Jung-Ryun
    Choi, Young Wook
    Kim, Hak Hee
    Chae, Eun Young
    Cho, Seungryong
    MEDICAL PHYSICS, 2017, 44 (02) : 417 - 425
  • [17] The potential for image guided radiation therapy with Cobalt-60 tomotherapy
    Schreiner, LJ
    Kerr, A
    Salomons, G
    Dyck, C
    Hajdok, G
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 2, 2003, 2879 : 449 - 456
  • [18] Evaluation of image quality in megavoltage digital tomosynthesis
    Descovich, M.
    Morin, O.
    Aubry, J.
    Aubin, M.
    Chen, H.
    Chen, J.
    Bani-Hashemi, A.
    Geffen, M.
    Kelly, K.
    Pang, G.
    Pouliot, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2281 - 2281
  • [19] Cobalt-60 Container Scanner
    安继刚
    周立业
    刘以思
    邬海峰
    吴志芳
    向新程
    王立强
    Tsinghua Science and Technology, 1999, (01) : 70 - 72+89
  • [20] COBALT-60 RADIATION MEASUREMENTS
    BRAESTRUP, CB
    MOONEY, RT
    RADIOLOGY, 1958, 70 (04) : 516 - 522