Sensitivity and Specificity of Serum and Synovial Fluid Markers in Diagnosis of Infection in Head-Neck Taper Corrosion of Metal-On-Polyethylene Total Hip Arthroplasty

被引:8
|
作者
Kwon, Young-Min [1 ]
Mahajan, John [1 ]
Tirumala, Venkatsaiakhil [1 ]
Oganesyan, Ruben [1 ]
Yeo, Ingwon [1 ]
Klemt, Christian [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Orthopaed Surg, Bioengn Lab, 55 Fruit St,Yawkey Suite 3B, Boston, MA 02114 USA
来源
JOURNAL OF ARTHROPLASTY | 2020年 / 35卷 / 12期
关键词
adverse local tissue reaction; periprosthetic joint infection; head-neck taper corrosion; cobalt and chromium metal ion level; metal-on-polyethylene total hip; arthroplasty; LOCAL TISSUE-REACTIONS; JUNCTION; OUTCOMES; UTILITY; STEM;
D O I
10.1016/j.arth.2020.06.058
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The accurate diagnosis of periprosthetic joint infection (PJI) in the setting of adverse local tissue reactions in patients with metal-on-polyethylene (MoP) total hip arthroplasty (THA) secondary to head-neck taper junction corrosion is challenging as it frequently has the appearance of purulence. The aim of this study is to evaluate the utility of erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and synovial fluid markers in diagnosing PJI in failed MoP THA due to head-neck taper corrosion. Methods: A total of 89 consecutive patients with MoP THA with head-neck taper corrosion in 2 groups was evaluated: (1) infection group (n = 11) and (2) noninfection group (n = 78). All patients had highly crossed polyethylene with cobalt chromium femoral heads and had preoperative synovial fluid aspiration. In addition, serum cobalt and chromium levels were analyzed. Results: The optimal cutoff value for synovial white blood cell was 2144 with 93% sensitivity and 84% specificity. Neutrophil count optimal cutoff value was 82% with 93% sensitivity and 82% specificity. Receiver operating characteristic analysis of ESR and CRP determined optimal cutoff at 57 mm/h and 35 mg/L with 57% sensitivity and 94% specificity and 93% sensitivity and 76% specificity, respectively. There were no significant differences in metal ion levels between the infected and noninfected groups. Conclusion: The results of this study suggest that ESR and CRP are useful in excluding PJI, whereas both synovial white blood cell count and neutrophil percentage in hip aspirate are useful markers for diagnosing infection in MoP THA patients with head-neck taper corrosion associated adverse local tissue reaction. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:3737 / 3742
页数:6
相关论文
共 49 条
  • [21] Sensitivity and Specificity of Metal Ion Levels in Predicting "Pseudotumors" due to Taper Corrosion in Patients With Dual Taper Modular Total Hip Arthroplasty
    Kwon, Young-Min
    Tsai, Tsung-Yuan
    Leone, William A.
    Liow, Ming Han Lincoln
    JOURNAL OF ARTHROPLASTY, 2017, 32 (03): : 996 - 1000
  • [22] Fretting and Corrosion Damage in Retrieved Metal-on-Polyethylene Modular Total Hip Arthroplasty Systems: What Is the Importance of Femoral Head Size?
    Siljander, Matthew P.
    Baker, Erin A.
    Baker, Kevin C.
    Salisbury, Meagan R.
    Thor, Clayton C.
    Verner, James J.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (03): : 931 - 938
  • [23] Iliopsoas Irritation as Presentation of Head-Neck Corrosion After Total Hip Arthroplasty: A Case Series
    Ko, Laura Matsen
    Coleman, Jacob J.
    Stas, Venessa
    Duwelius, Paul J.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (04) : 461 - +
  • [24] Metal allergy response to femoral head-neck corrosion after total hip replacement
    Meftah, Morteza
    Nicolaou, Nicos
    Rodriguez, Jose A.
    CURRENT ORTHOPAEDIC PRACTICE, 2010, 21 (05): : 530 - 533
  • [25] Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty-MRI versus ultrasonography performed by an orthopedic surgery resident
    Mikkelsen, Rasmus T.
    Schou, Martin
    Torfing, Trine
    Graumann, Ole
    Overgaard, Soren
    Varnum, Claus
    ACTA RADIOLOGICA OPEN, 2023, 12 (02)
  • [26] Bilateral Mechanically-Assisted Crevice Corrosion Resulting in Femoral Stem-Head Dissociation in Metal-on-Polyethylene Total Hip Arthroplasty
    Mcaleese, Timothy
    Feeley, Iain
    Hughes, Andrew
    Sheehan, Eoin
    Merghani, Khalid
    Niall, Dorothy
    ARTHROPLASTY TODAY, 2021, 8 : 35 - 39
  • [27] Utility of Serum Inflammatory and Synovial Fluid Counts in the Diagnosis of Infection in Taper Corrosion of Dual Taper Modular Stems
    Kwon, Young-Min
    Antoci, Valentin, Jr.
    Leone, William A.
    Tsai, Tsung-Yuan
    Dimitriou, Dimitris
    Liow, Ming Han Lincoln
    JOURNAL OF ARTHROPLASTY, 2016, 31 (09): : 1997 - 2003
  • [28] Increased Femoral Head Offset is Associated With Elevated Metal Ions in Asymptomatic Patients With Metal-on-Polyethylene Total Hip Arthroplasty
    Martin, John R.
    Camp, Christopher L.
    Wyles, Cody C.
    Taunton, Michael J.
    Trousdale, Robert T.
    Lewallen, David G.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (12): : 2814 - 2818
  • [29] Pseudotumours, cobalt and clinical outcome in small head metal-on-metal versus conventional metal-on-polyethylene total hip arthroplasty
    van der Veen, Hugo C.
    Reininga, Inge H. F.
    Zijlstra, Wierd P.
    Boomsma, Martijn F.
    Bulstral, Sjoerd K.
    van Raay, Jos J. A. M.
    HIP INTERNATIONAL, 2020, 30 (01) : 56 - 63
  • [30] Adverse local tissue reactions in metal-on-polyethylene total hip arthroplasty due to trunnion corrosion THE RISK OF MISDIAGNOSIS
    Whitehouse, M. R.
    Endo, M.
    Zachara, S.
    Nielsen, T. O.
    Greidanus, N. V.
    Masri, B. A.
    Garbuz, D. S.
    Duncan, C. P.
    BONE & JOINT JOURNAL, 2015, 97B (08): : 1024 - 1030